1.
Braz. dent. sci ; 25(2): 1-9, 2022. tab, ilus
Article in English | LILACS, BBO | ID: biblio-1368562

ABSTRACT

Objective: To determine the effect of the restorative technique, material's opacity and the selected light sources on the curing potential (CP) in deep cavities. Material and Methods: The radiant exitance (mW/cm2) of two light curing units (Bluephase G2 and Radii-Cal) was determined at 0 and 8 mm distance from a power meter sensor (Ophir). Two bulk-fill composites of regular consistency (Opus, FGM; and Filtek One, 3M) and a conventional one (Sirius-Z, DFL) were considered and the level of their opacity were determined by a sphere-based spectrophotometer (SP60, X-Rite). The degree of C=C conversion (DC) was determined by spectroscopy (FTIR-ATR) at 0.05 and 8 mm depths and the CP considered the ratio between them. The "incremental technique" considered 4 increments of 2mm thickness each, whereas the "bulk-fill technique considered 2 increments of 4mm-thickness. Data were submitted to analysis of variance and Tukey's test (95%). Pearson's correlation tests were performed to calculate the possible relation between curing potential and materials' opacity. Results: With the incremental technique it was possible to achieve high CP regardless of the light source. The CP of bulk-fill composites was dependent on the light source, whereas Radii-Cal compromised the DC at 8 mm for both materials. The correlation between opacity and CP was dependent on the light source (r = 0.891707246 for Radii-Cal; r = 0.515703768 for Bluephase G2). Conclusion: The bulk-fill technique was dependent on the light source while the incremental was not. The influence of materials' opacity was dependent on the light curing unit.(AU)


Objetivo: Determinar o efeito da técnica restauradora, a opacidade do material e as fontes de luz selecionadas sobre o potencial de cura (PC) em cavidades profundas. Materiais e métodos: A saída radiante (mW/cm2) de duas unidades de cura por luz (Bluephase G2 e Radii-Cal) foi determinada a 0 e 8 mm de distância de um sensor de potência (Ophir). Dois compósistos bulkfill de consistência regular (Opus, FGM; e Filtek One, 3M) e um convencional (Sirius-Z, DFL) foram considerados e o nível de sua opacidade foi determinado por um espectrofotômetro (SP60, X-Rite). O grau de conversão C=C (DC) foi determinado por espectroscopia (FTIR-ATR) a 0,05 e 8 mm de profundidade e o PC considerou a relação entre eles. A técnica incremental considerou 4 incrementos de 2 mm de espessura cada, enquanto que a técnica bulkfill considerou 2 incrementos de 4 mm de espessura. Os dados foram submetidos à análise de variância e ao teste de Tukey (95%). Os testes de correlação de Pearson foram realizados para calcular a possível relação entre o potencial de cura e a opacidade dos materiais. Resultados: Com a técnica incremental foi possível obter um PC elevado, independentemente da fonte de luz. O PC de compósitos bulkfill foi dependente da fonte de luz, enquanto que Radii-Cal comprometeu o DC em 8 mm para ambos os materiais. A correlação entre opacidade e PC foi dependente da fonte de luz (r = 0,891707246 para Radii-Cal; r = 0,515703768 para Bluephase G2). Conclusão: O potencial de polimerização para a técnica bulkfill foi dependente da fonte de luz, enquanto para a técnica incremental não. A influência da opacidade dos materiais sobre a capacidade de polimerização foi dependente da unidade de fotoativação. (AU)


Subject(s)
Spectrophotometers , Composite Resins , Dental Materials , Curing Lights, Dental , Polymerization
2.
Braz. dent. sci ; 25(3): 1-10, 2022. tab, ilus
Article in English | LILACS, BBO | ID: biblio-1372961

ABSTRACT

Objetivo: O objetivo deste estudo é avaliar o efeito de múltiplas queimas e envelhecimento na cor e na translucidez da vitrocerâmica de dissilicato de lítio reprensada (IPS e.max press). Material e Métodos: Um total de 42 discos de dissilicato de lítio (15 mm x 1 mm) foram fabricados usando a técnica de prensa térmica seguindo as instruções dos fabricantes. Eles foram divididos em três grupos de acordo com o número de ciclos de prensagem (n=14): Grupo P1 (pressionado uma vez), Grupo P2 (pressionado duas vezes) e Grupo P3 (pressionado três vezes). Cada grupo foi subdividido em dois subgrupos de acordo com o número de ciclos de queima (n=7): Subgrupo (F2): 2 ciclos de queima, Subgrupo (F4): 4 ciclos de queima. Em seguida, todos os corpos de prova foram submetidos à termociclagem. Os parâmetros de cor e translucidez (TP) foram avaliados por espectrofotômetro; após a prensagem, queima (ΔE1: diferença de cor entre prensagem e queima) e envelhecimento (ΔE2: diferença de cor entre prensagem e envelhecimento). Resultados:ΔE1 para o subgrupo F2 (3,38) apresentou menor valor estatisticamente significante do que ΔE1 para o subgrupo F4 (3,94). Após o envelhecimento, o grupo P3 apresentou o maior ΔE2 estatisticamente significante (6,41). Um ΔE2 estatisticamente inferior foi encontrado no grupo P2 (5,55). O grupo P1 apresentou o menor ΔE2 estatisticamente significante (4,28). O TP para o subgrupo F2 (18,27) apresentou valor superior ao subgrupo F4 (17,78). Houve uma diminuição estatisticamente significante no TP após o envelhecimento para todos os grupos testados. Conclusão: O aumento do número de ciclos de queima e de envelhecimento afetaram a cor e a translucidez do dissilicato de lítio reprensado. (AU)


Objective: The aim of this study is to evaluate the effect of multiple firings and aging on color and translucency of repressed lithium disilicate glass ceramic (IPS e.max press). Material and Methods: A total of 42 lithium disilicate discs (15 mm x 1 mm) were fabricated using heat press technique following the manufacturers' instructions. They were divided into three groups according to the number of pressing cycles (n=14): Group P1 (pressed once), Group P2 (pressed twice) and Group P3 (pressed thrice). Each group was subdivided into two subgroups according to the number of firing cycles (n=7): Subgroup (F2): 2 firing cycles, Subgroup (F4): 4 firing cycles. Then all specimens were subjected to thermocycling. Color and translucency parameter (TP) were evaluated by spectrophotometer; after pressing, firing (ΔE1: color difference between pressing and firing) and aging (ΔE2: color difference between pressing and aging). Results:ΔE1 for subgroup F2 (3.38) showed statistically significant lower value than ΔE1 for subgroup F4 (3.94). After aging, group P3 showed the statistically significant highest ΔE2 (6.41). A statistically significant lower ΔE2 was found with group P2 (5.55). Group P1 showed the statistically significant lowest ΔE2 (4.28). TP for subgroup F2 (18.27) showed higher value than subgroup F4 (17.78). There was a statistically significant decrease in TP after aging for all tested groups. Conclusion: Increasing the number of firing cycles and aging affected color and translucency of repressed lithium disilicate. (AU)


Subject(s)
Aging , Spectrophotometers , Color , Dental Materials
3.
Sâo José dos Campos; s.n; 2021. 81 p. ilus, tab.
Thesis in Portuguese | LILACS, BBO | ID: biblio-1359830

ABSTRACT

O objetivo deste estudo foi comparar as técnicas de microabrasão de esmalte (ME) e infiltração de resina (IR) em relação à resolução estética de lesões cariosas de mancha branca (LCMB) e avaliar a correlação entre a luminosidade das lesões quando transiluminadas e a resolução do problema (estudo 1); avaliar em um estudo "in vitro", a eficácia do clareamento dental, em amostras de dentes submetidos previamente a IR (estudo 2); avaliar a efetividade do clareamento dental 12 meses após a realização dos protocolos de mínima intervenção, em um estudo de série de casos (estudo 3). Para o estudo 1 foram selecionados 17 pacientes que foram divididos em 2 grupos: ME (N=8) e IR (N=9). Um dente de cada paciente foi fotografado sob condição normal e do mesmo dente com auxilio de dispositivo translume. Em seguida os pacientes foram submetidos às técnicas de mínima intervenção. Após 7 dias de acompanhamento, o mesmo protocolo fotográfico foi realizado. Para resolução estética, foi delimitado a área do dente em relação a área da mancha por software. Para avaliação da cor da mancha quando evidenciada, os valores de luminosidade (L*) das coordenadas L*a*b* foram avaliados antes e após a intervenção, sendo mensurados valores das áreas sadias e área da mancha mais enegrecida. Os dados de correlação foram submetidos ao teste de Person. A resolutividade dos tratamentos foi dada por um Teste t-Student e a diferença de luminosidade antes e após os tratamentos foi dado pelo teste Anova 2 fatores de medidas repetidas (p<0,05). Para o estudo 2, quarenta superfícies de esmalte bovino foram submetidas à desmineralização. Após, foram estabelecidos dois protocolos de manchamento. Vinte espécimes foram imersos em caldo de manchamento por 24 horas (Lab 1) ou 7 dias (Lab 2). Dez corpos-de-prova de cada grupo receberam a aplicação de IR. Todas as amostras foram clareadas com gel de peróxido de carbamida 15% por 14 dias (8 horas diárias). A mensuração da cor foi realizada em espectrofotômetro de refletância em três momentos: inicial, após o manchamento e após o clareamento. Os dados (CIEDE00) foram analisados pelo teste t-Student (p <0,05). Para o estudo 3, foram selecionados 4 voluntários, que tinham LCMB nos dentes anteriores superiores. Os pacientes foram divididos de forma aleatória em dois grupos, sendo estes: ME e IR na área de mancha. Para resolução estética das LCMB, foi determinada a área da mancha em relação a área do dente e a porcentagem da redução pós protocolos. Após 12 meses de acompanhamento, os pacientes receberam clareamento dental, com peróxido de carbamida 10%, durante 21 dias. Os dados do estudo 1 mostram que não houve correlação entre as áreas da mancha (normal e transiluminada) e a resolução estética das mesmas (p>0.05). Em relação a resolutividade, não houve diferença entre os tratamentos (p=0.403). O valor de Luminosidade aumentou após a realização dos procedimentos (p=0.001). Para o estudo 2, nenhuma diferença significativa foi observada no Lab 1 (p=0,560). Para o Lab 2, foram detectadas diferenças significativas (p=0,031). Uma vez que o clareamento foi mais efetivo no grupo não submetido a IR (Lab2). Os resultados do estudo 3 mostram que ambos os protocolos reduziram e/ou suavizaram as áreas das manchas. Após 12 meses de acompanhamento, a técnica de ME apresentou redução no valor da área de mancha. Por fim, o clareamento dental foi efetivo em ambos os protocolos, sem diferenças entre as técnicas. Frente as metodologias propostas, pode-se concluir que: não houve diferenças entre os tratamentos em relação a remoção ou mascaramento das LCMB; a cor das manchas quando transiluminadas não estão relacionadas a resolução estética das mesmas; "in vitro", dentes fortemente manchados, submetidos ao tratamento com RI, o produto parece se comportar como uma barreira semipermeável à penetração do peróxido. Por fim, ambas as técnicas podem ser indicadas para reduzir ou suavizar as áreas de mancha. A ME apresentou redução das áreas de mancha no período avaliado (12 meses). Clinicamente, o clareamento dental pode ser indicado para melhorar a cor dos dentes, independentemente do protocolo pré-estabelecido


The aim of this study was to compare enamel microabrasion (EM) and resin infiltration (RI) techniques in relation to the esthetic resolution of white spot carious lesions (WSL) and to evaluate the correlation between the luminosity of the lesions when transilluminated and the resolution of the problem (study 1); To evaluate in an "in vitro" study, the effectiveness of dental bleaching in samples of teeth previously submitted to RI (study 2); to evaluate the effectiveness of dental bleaching 12 months after the minimal intervention protocols were performed, in a case series study (study 3). For study 1, 17 patients were selected and divided into 2 groups: ME (N=8) and IR (N=9). One tooth from each patient was photographed under normal condition and the same tooth with the aid of a translume device. Then the patients were subjected to the minimal intervention techniques. After 7 days of follow-up, the same photographic protocol was performed. For esthetic resolution, the area of the tooth was delimited in relation to the area of the stain using software. To evaluate the color of the stain when evidenced, the luminosity values (L*) of the coordinates L*a*b* were evaluated before and after the intervention, being measured values of the healthy areas and area of the darker stain. The correlation data were submitted to Person's test. The resolution by the treatments was analyzed by Student's t-test, and the difference in luminosity before and after treatments was analyzed by 2-way repeated measures Anova (p<0.05). For study 2, forty bovine enamel surfaces were subjected to demineralization. Two staining protocols were established. Twenty specimens were immersed in staining broth for 24 hours (Lab 1) or 7 days (Lab 2). Ten specimens from each group received IR application. All specimens were bleached with 15% carbamide peroxide gel for 14 days (8 hours daily). Color measurement was performed by spectrophotometry at three periods: bselien, after staining, and after bleaching. Data (CIEDE00) were analyzed by Student's T test (p <0.05). For study 3, 4 volunteers with WSL in the maxillary teeth were selected. The patients were randomly divided into EM or RI for treating lesions. For esthetic resolution of WSL, the spot area relative to tooth area and the percentage of reduction after protocols were determined. After 12 months of follow-up, the patients received dental bleaching with 10% carbamide peroxide for 21 days. The data from study 1 show that there was no correlation between the stain areas (transilluminated or not) and the esthetic resolution (p>0.05). Regarding resolution, there was no difference between treatments (p=0.403). The Luminosity value increased after the procedures were performed (p=0.001). For study 2, no significant difference was observed in Lab 1 (p=0.560). For Lab 2, significant differences were detected (p=0.031), and whitening was more effective in the group not subjected to IR (Lab2). The results of study 3 show that both protocols reduced and/or softened the areas of the stains. After 12 months of follow-up, the EM technique showed a reduction in the stain area value. Finally, dental bleaching was effective with both protocols, with no differences between the techniques. Based on the proposed methodologies, it can be concluded that: there were no differences between the treatments regarding the removal or masking of WSL; the color of the stains when transilluminated is not related to their esthetic resolution; "in vitro", heavily stained teeth submitted to treatment with RI, the product seems to behave as a semi-permeable barrier to peroxide penetration. Finally, both techniques can be indicated to reduce or soften stained areas. The EM showed a reduction of stained areas in the evaluated period (12 months). Clinically, dental bleaching can be indicated to improve the color of teeth, regardless of the pre-established protocol


Subject(s)
Humans , Animals , Cattle , Tooth Bleaching , Enamel Microabrasion , Dental Caries , Dental Leakage , Esthetics, Dental , Spectrophotometers , Analysis of Variance , Color
4.
Article in English | LILACS, BBO | ID: biblio-1287487

ABSTRACT

ABSTRACT Objective: To assess the 6-month efficacy of natural tooth color change in in-office bleaching treatment in terms of time by using a spectrophotometer. Material and Methods: A total of 20 participants were chairside treated with 40% hydrogen peroxide (HP), three applications each 20 minutes, in one appointment. Instrumental color measurement was performed on six anterior maxillary teeth before bleaching (baseline-t0), immediately after in-office bleaching and rehydration of the teeth (t1), 3 months (t2), and 6 months after bleaching treatment (t3). The spectrophotometer measured the tooth shades based on the CIE L*a*b* color notation system and Bleach index during the period of observation. CIE L*a*b* (ΔEab) color differences were calculated. Results: The color change at t1 was ΔEab = 3.2, at t2 was ΔEab = 1.8, at t3 was ΔEab = 1.2 and overall color change of in-office method was ΔEab = 3.6 (p<0.05). A significant effect for the mean CIEL*a*b* values was detected as within time b* values decreased significantly (p<0.05). Bleach index values significantly decreased during the time of observation, too (p<0.05). Conclusion: The in-office bleaching treatment using 40% hydrogen peroxide was effective, and the results showed a statistically significant decrease in color change during the period of 6-month observation.


Subject(s)
Humans , Male , Female , Adult , Tooth Bleaching , Spectrophotometers , Dental Offices , Tooth Bleaching Agents/chemistry , Hydrogen Peroxide/therapeutic use , Analysis of Variance , Data Interpretation, Statistical , Treatment Outcome , Bosnia and Herzegovina , Statistics, Nonparametric
5.
Braz. dent. sci ; 24(4, suppl 1): 1-9, 2021. tab, ilus
Article in English | LILACS, BBO | ID: biblio-1352598

ABSTRACT

Objective: To compare the color stability and translucency of aged and unaged experimental zirconia reinforced rice husk nanohybrid composite resin (Zr-Hybrid) with a commercialized nanofilled and a microhybrid composite resin after immersion in four different infusion media. Material and Methods: Three groups of standardized disc-shaped composite resin with 80 samples per group were prepared as follow: Group 1 (Filtek-Z350-XT), Group 2 (Zmack-Comp), and Group 3 (Zr-Hybrid). Each group was further subdivided into aged (n=40) and unaged (n=40) groups. Initial color measurements were taken using a digital spectrophotometer based on CIE L*a*b* color system. Samples in aged subgroup were subjected to 2500 thermal cycles. Subsequently, all samples were immersed in four different types of infusion media (n=10): T1 - Distilled water, T2 - Soft drink, T3 - Tea and T4 - Coffee. After 15 days, color measurements of all samples were measured again. Data were analyzed using two-way ANOVA followed by Bonferroni and paired sample t-tests with a significance level set at P=0.05. Results: Unaged Zr-Hybrid showed comparable color change to Zmack-Comp and Filtek-Z350-XT (P=0.181), but aged Zr-Hybrid demonstrated the lowest color change (P<0.001). Zr-Hybrid exhibited the lowest translucency value (P<0.001), but no significant color and translucency changes (P=0.051 and P=0.069, respectively) were observed between unaged and aged Zr-Hybrid. Soft drink had the greatest effect (P<0.001) on color change, while coffee showed the greatest effect (P<0.001) on translucency. Conclusion: Although Zr-Hybrid showed greater opacity, it still retained its color stability and translucency after accelerated aging compared to commercialized microhybrid and nanofilled composite resins. All infusion media caused discoloration and affected the composite resins' translucency. (AU)


Objetivo: Comparar a estabilidade de cor e translucidez de uma resina composta nanohíbrida de casca de arroz reforçada com zircônia experimental envelhecida e não envelhecida (Zr-Hybrid) com uma resina composta comercial nanoparticulada e microhíbrida após a imersão em quatro meios de infusão diferentes. Material e Métodos: Três grupos de resina composta em forma de disco padronizado com 80 amostras por grupo foram preparados da seguinte forma: Grupo 1 (Filtek-Z350-XT), Grupo 2 (Zmack-Comp) e Grupo 3 (Zr-Hybrid). Cada grupo foi subdividido em grupos de envelhecimento (n = 40) e não envelhecimento (n = 40). As medições iniciais de cor foram feitas usando um espectrofotômetro digital baseado no sistema de cores CIE L * a * b *. As amostras do subgrupo envelhecido foram submetidas a 2500 ciclos térmicos. Posteriormente, todas as amostras foram imersas em quatro tipos diferentes de meios de infusão (n = 10): T1 - Água destilada, T2 - Refrigerante,T3 - Chá e T4 - Café. Após 15 dias, as medições de cor de todas as amostras foram medidas novamente. Os dados foram analisados usando ANOVA dois fatores seguido por Bonferroni e testes t pareados com nível de significância estabelecido em P = 0,05. Resultados: O grupo Zr-Hybrid não envelhecido mostrou uma mudança de cor comparável a Zmack-Comp e Filtek-Z350-XT (P = 0,181), mas o grupo Zr-Hybrid envelhecido demonstrou a menor mudança de cor (P <0,001). Zr-Hybrid exibiu o menor valor de translucidez (P <0,001), mas nenhuma mudança significativa de cor e translucidez (P = 0,051 e P = 0,069, respectivamente) foram observadas entre Zr-Hybrid não envelhecido e envelhecido. O refrigerante teve o maior efeito (P <0,001) na mudança de cor, enquanto o café apresentou o maior efeito (P <0,001) na translucidez. Conclusão: Apesar do grupo Zr-Hybrid tenha mostrado maior opacidade, ele ainda manteve sua estabilidade de cor e translucidez após envelhecimento acelerado em comparação com resinas compostas micro-híbridas e nanoparticuladas comercializadas. Todos os meios de infusão causaram descoloração e afetaram a translucidez das resinas compostas (AU)


Subject(s)
Spectrophotometers , Composite Resins
6.
Braz. dent. sci ; 24(3): 1-9, 2021. tab, graf
Article in English | LILACS, BBO | ID: biblio-1282216

ABSTRACT

Objective: The aim of this study is to evaluate the effect of varying thickness and artificial aging on the color and translucency of cubic zirconia and lithium disilicate ceramics. Material and Methods: A total of 30 square shaped disks (12 mm x 12 mm) were fabricated from the cubic zirconia (Bruxzir Anterior) blank and lithium disilicate blocks (E.max CAD), used in three thicknesses (0.5mm, 0.8mm and 1mm). Portable spectrophotometer Vita Easyshade Advance was used to obtain color coordinates, which were substituted in formulas and used to calculate color change and translucency parameter values before and after aging (thermocycling for lithium disilicate and hydrothermal aging for cubic zirconia). Repeated measures Analysis of Variance (ANOVA) was used to study the effect of ceramic type, thickness, aging and their interaction on mean translucency parameter. Two-way (ANOVA) was used to study the effect of ceramic type, thickness and their interaction on mean color change (ΔE). Results: Statistical analysis showed that E.max CAD HT is more translucent than Bruxzir Anterior. Translucency decreased as thickness increased. There was a statistically significant decrease in TP after aging for both materials. Lithium disilicate showed statistically significant greater ΔE when subjected to aging than cubic zirconia, with both ΔE values being clinically imperceptible. As thickness increased, ΔE decreased. Conclusions: Thickness highly affected translucency and color of ceramics. As thickness increases, translucency parameter decreases and color change becomes less evident. Aging also causes a significant decrease in translucency parameter and induces color change however color changes are imperceptible. (AU)


Objetivo: O objetivo deste estudo é avaliar o efeito de diferentes espessuras e do envelhecimento artificial na cor e translucidez de cerâmicas de zircônia cúbica e dissilicato de lítio. Material e Métodos: Um total de 30 discos (12 mm x 12 mm) foram fabricados a partir de um bloco branco de zircônia cúbica (Bruxzir Anterior) e blocos de dissilicato de lítio (E.max CAD) em três diferentes espessuras (0,5mm, 0,8mm e 1mm). Um espectrofotômetro portátil Vita Easyshade Advance foi utilizado para obter as coordenadas de cores, que foram substituídas nas fórmulas e usadas para calcular os valores dos parâmetros de mudança de cor e translucidez antes e depois do processo de envelhecimento (termo ciclagem para dissilicato de lítio e envelhecimento hidrotérmico para zircônia cúbica). A análise de variância de medidas repetidas (ANOVA) foi usada para estudar o efeito do tipo de cerâmica, a espessura, o envelhecimento e a sua interação no parâmetro de translucidez média. Two-way (ANOVA) foi usado para estudar o efeito do tipo da cerâmica, espessura e sua interação na alteração de cor média (ΔE). Resultados: a análise estatística mostrou que a cerâmica E.max CAD HT é mais translúcida que Bruxzir Anterior. A translucidez diminuiu com o aumento da espessura. Houve uma diminuição estatisticamente relevante no TP após o envelhecimento para ambos os materiais. O dissilicato de lítio apresentou maior ΔE estatisticamente relevante quando submetido ao envelhecimento quando comparado com a zircônia cúbica, sendo ambos os valores de ΔE clinicamente imperceptíveis. Conforme a espessura aumentou, o ΔE diminuiu. Conclusão: a espessura afetou expressivamente na translucidez e cor das cerâmicas. À medida que a espessura aumentou, os parâmetros de translucidez diminuíram e a mudança de coloração se tornou menos evidente. O envelhecimento também causou uma diminuição significativa no parâmetro de translucidez das cerâmicas de zircônia cúbica e dissilicato de lítio. (AU)


Subject(s)
Aging , Spectrophotometers
7.
Braz. dent. sci ; 24(2): 1-7, 2021. tab
Article in English | LILACS, BBO | ID: biblio-1178275

ABSTRACT

Objective: The objective of the present in-vitro study was to verify the efficacy of two spectrophotometer-based shade matching systems for color matching of ceramics after artificial accelerated aging (AAA). Material and Methods: The ceramics used were porcelain laminated veneers. Seventy standard-shaped discs (thickness x diameter: 0.5 mm x 10 mm) of B1 shades were used. Based upon the type of resin cement used, the specimens were divided into seven groups (10/group). The following light-cured cements were used: RelyX-Veneer (L-RV), Variolink-Veneer (L-VV), and Variolink-Esthetic (L-VE). The dual-cured cements were: RelyX Ultimate (D-RU), RelyX-Unicem (D-RC), and Variolink-Esthetics DC (D-VE). The control group consisted of ceramic only. All specimens were thermocycled in water for 3,500 cycles between 5 oC -55 oC, with dwell times of 30 s in each bath and a transfer time of 10 s between baths. All specimens were thermocycled in water for 3,500 cycles between 5 oC and 55 oC, and color measurement was done using the VITA Easyshade and ColorEye spectrophotometers. Baseline color reading was performed 24-hours after cementation. Differences in color (DE) of EasyShade and ColorEye before and after AAA were determined and compared statistically. Group comparisons were done using the paired t-tests. Level of significance was set at P< 0.05. Results: The mean differences in color (ΔE) values obtained from EasyShade spectrophotometer for light- and dual-cured cements, were 0.843±0.89 (L-RV ), 4.11±0.69 (L-VV) and 0.833±0.47 (L-VE); and 2.22±0.64 (D-RU), 3.37±0.83 (D-RC) and 0.38±0.92 (D-VE), respectively. The mean differences in color (ΔE) values obtained from ColorEye spectrophotometer for light- and dual-cured cements, were 0.68±0.86 (L-RV ), 4.55±0.83 (L-VV) and 2.68±0.26 (L-VE); and 2.06±0.84 (D-RU), 1.8±1.08 (D-RC) and 0.96±0.71 (D-VE), respectively. There was no significant difference in the mean DE values among the groups. Conclusion: The VITA Easyshade and ColorEye shade matching systems are comparable in terms of their efficacy for color matching of cerammics after AAA.(AU)


Objetivos: O objetivo do presente estudo in vitro foi verificar a eficácia de dois espectrofotômetros baseados em escalas de cor para avaliação de cor de cerâmicas após envelhecimento artificial acelerado (EAA). Material e Métodos: As cerâmicas utilizadas foram laminados cerâmicos. Foram usados setenta discos de formato padrão (0,5mm de espessura x 10 mm de diâmetro) de tonalidades B1. Com base no tipo de cimento resinoso utilizado, os corpos-de-prova foram divididos em sete grupos (10 / grupo). Foram utilizados os seguintes cimentos fotopolimerizáveis: RelyX-Veneer (L-RV), Variolink-Veneer (L-VV) e Variolink-Esthetic (L-VE). Os cimentos de cura dual foram: RelyX Ultimate (D-RU), RelyX-Unicem (D-RC) e Variolink-Esthetics DC (D-VE). O grupo controle consistia apenas de cerâmica. Todos os corpos-de-prova foram termociclados em água por 3.500 ciclos entre 5oC-55oC, com tempos de permanência de 30s em cada banho e um tempo de transferência de 10s entre os banhos. A medição da cor foi feita usando os espectrofotômetros VITA Easyshade e ColorEye. A leitura da cor inicial foi realizada 24 horas após a cimentação. As diferenças na cor (ΔE) do EasyShade e ColorEye antes e depois do EAA foram determinadas e comparadas estatisticamente. As comparações dos grupos foram feitas usando o teste t pareados. O nível de significância foi estabelecido em p <0,05. Resultados: os valores médios de diferenças na cor (ΔE) obtidos no espectrofotômetro EasyShade para cimentos fotopolimerizáveis e duais foram de 0,843 ± 0,89 (L-RV), 4,11 ± 0,69 (L-VV) e 0,833 ± 0,47 (L-VE ); e 2,22 ± 0,64 (D-RU), 3,37 ± 0,83 (D-RC) e 0,38 ± 0,92 (D-VE), respectivamente. os valores médios de diferenças na cor (ΔE) obtidos no espectrofotômetro ColorEye para cimentos fotopolimerizáveis e duais foram de 0,68 ± 0,86 (L-RV), 4,55 ± 0,83 (L-VV) e 2,68 ± 0,26 (L-VE); e 2,06 ± 0,84 (D-RU), 1,8 ± 1,08 (D-RC) e 0,96 ± 0,71 (D-VE), respectivamente. Não houve diferença significativa nos valores médios de ΔE entre os grupos. Conclusão: Os sistemas de combinação de cores VITA Easyshade e ColorEye são comparáveis em termos de eficácia para avaliação de cores de cerâmicas após EAA. (AU)


Subject(s)
In Vitro Techniques , Spectrophotometers , Dental Materials , Dental Veneers
8.
Rev. odontol. UNESP (Online) ; 49: e20200045, 2020. tab, ilus
Article in English | LILACS, BBO | ID: biblio-1139419

ABSTRACT

Introduction: Considering the increased search for esthetic procedures, questions emerge about the maintenance and regression of color, especially regarding the need to restrict dark foods during bleaching procedures or their influence on the stability and effectiveness of the treatment. Objective: To assess the influence of staining agents on tooth enamel during immediate bleaching treatment with 35% hydrogen peroxide. Material and method: Sixty bovine teeth were divided into six groups (G) (n=10): G1: distilled water (control); G2: coffee; G3: cola soft drink; G4: wine; G5: mate tea; and G6: industrialized açaí. The samples were subjected to immediate bleaching using 35% hydrogen peroxide for 21 days (three applications of 15 minutes per session, every seven days) and pigment immersion between each session for 15 minutes. The color was assessed before starting bleaching and after 21 days, using a spectrophotometer. The data obtained were subjected to one-way ANOVA and heteroscedasticity analysis by the Welch and Brown-Forsythe tests. The Tamhane test was used for group comparison. Result: The color change was visible to the naked eye, considering the mean ΔE in all groups tested was higher than 3.7. However, there was no statistical difference between the control group and the groups assessed. Conclusion: The contact of staining agents on bovine tooth enamel did not affect the final result of the immediate tooth bleaching.


Introdução: Com o aumento da procura por procedimentos estéticos, dúvidas surgem quanto à manutenção e regressão de cor, especialmente, no que tange a necessidade de restrição quanto à alimentos escuros durante o procedimento clareador ou a sua influência quanto à estabilidade e eficácia do tratamento. Objetivo: Avaliar a influência de agentes pigmentantes sobre o esmalte dental durante o tratamento clareador imediato com peróxido de hidrogênio a 35%. Material e método: 60 dentes bovinos foram divididos em 6 grupos (G) (n=10): G1: água destilada (controle), G2: café, G3: refrigerante à base de cola, G4: vinho, G5: chá-mate, e G6: açaí industrializado. As amostras foram submetidas ao clareamento imediato utilizando peróxido de hidrogênio a 35% durante 21 dias (3 aplicações de 15 minutos por sessão a cada 7 dias) e submetidas à imersão dos pigmentos entre cada sessão durante 15 minutos. A avaliação da cor foi realizada antes do inicio do clareamento e após 21 dias, mediante o uso do espectrofotômetro. Os dados obtidos foram submetidos ao ANOVA one-way e análise de heterocedasticidade pelos testes de Welch e Brown-Forsythe. O teste de Tamhane foi utilizado para a comparação entre os grupos. Resultado: Houve alteração de cor visível ao olho nu, uma vez que a média de ΔE em todos os grupos testados foi maior que 3,7. Contudo, não houve diferença estatística entre o grupo controle em relação aos grupos avaliados. Conclusão: O contato de agentes pigmentantes no esmalte dental bovino não influenciou o resultado final do clareamento dental imediato.


Subject(s)
Cattle , Tooth Bleaching , Pigmentation , Cattle , Spectrophotometers , Dental Enamel , Coloring Agents , Hydrogen Peroxide , Analysis of Variance , Color
9.
Article in English | LILACS, BBO | ID: biblio-1135509

ABSTRACT

Abstract Objective: To determine the total level of flavonoids in brown algae extract Padina sp., Sargassum sp., and Turbinaria sp., which could serve as an analgesic and anti-inflammatory drug. Material and Methods: This is an experimental study with a one-shot case study research design. The study sample consisted of three species of brown algae, namely, Padina sp., Sargassum sp., and Turbinaria sp. The study samples were obtained from Saugi Island, Pangkep, Regency. The sampling method used was convenience sampling. The total flavonoid level in the three extracts of brown algae samples was determined at three concentrations (150 ppm, 300 ppm, and 450 ppm) with three replicates. The analysis used a colorimetric method, a spectrophotometer and aluminium chloride as the reagent. Results: The total level of flavonoids in Padina sp. was the highest at 0.894 ± 0.027%, compared to the levels of 0.786 ± 0.075% in Sargassum sp. and 0.745 ± 0.016% in Turbinaria sp. Conclusion: Padina sp. had the highest total flavonoid levels compared to Sargassum sp. and Turbinaria sp. Flavonoid compounds from brown algae have the potential to be used as analgesic and anti-inflammatory drugs.


Subject(s)
Seaweed , Flavonoids , Phaeophyta , Phytochemicals , Anti-Inflammatory Agents/therapeutic use , Research Design , Pharmaceutical Preparations , Spectrophotometers/methods , Intervention Studies , Statistics, Nonparametric , Sargassum , Indonesia/epidemiology
10.
Braz. arch. biol. technol ; 62: e19180266, 2019. tab, graf
Article in English | LILACS | ID: biblio-1055379

ABSTRACT

Abstract Phytochemical content of plant extracts can be used effectively to reduce the metal ions to nanoparticles in one-step green synthesis process. In this study, six plant extracts were used for the synthesis of silver nanoparticles (AgNPs). Biologically synthesized AgNPs was characterized using UV-Vis Spectrophotometer, Field Emission Scanning Electron Microscope (FE-SEM), X-ray diffraction (XRD), Energy Dispersive X-ray spectroscopy (EDX) and Fourier Transform Infrared (FTIR) spectroscopy. The individual and combined effects of AgNPs and tetracycline against S. aureus and K. pneumoniae were assessed. Ginger, onion and sidr extracts supported AgNPs formation while arak, garlic and mint extracts failed to convert the silver ions to AgNPs. The present findings revealed significant differences between the tested plant extracts in supporting AgNPs synthesis. AgNPs synthesized by ginger showed the highest individual and combined activity against tested strains followed by AgNPs prepared by sidr then that synthesized by onion. AgNPs significantly enhanced tetracycline activity (p≤0.05) against S. aureus and K. pneumoniae. The results of this study demonstrated that the combination of tetracycline and biologically synthesized AgNPs presented a useful therapeutically method for the treatment of bacterial infection and counterattacking bacterial resistance.


Subject(s)
Silver/pharmacology , Staphylococcus aureus/drug effects , Tetracycline/biosynthesis , Plant Extracts/biosynthesis , Klebsiella pneumoniae/drug effects , Spectrometry, X-Ray Emission/instrumentation , X-Ray Diffraction/instrumentation , Spectrophotometers/methods , Spectroscopy, Fourier Transform Infrared/instrumentation
11.
Braz. dent. sci ; 22(2): 203-212, 2019. ilus, tab
Article in English | LILACS, BBO | ID: biblio-996690

ABSTRACT

Objective: Despite the higher translucency of nanocrystalline Y-TZP than the conventional Y-TZP, it couldn't be used in the anterior region of the mouth in its fully anatomical form without veneering for better esthetics. This study evaluated the color change (ΔE) and translucency parameter (TP) of the bilayered nano-crystalline zirconia restorations after different treatments of the zirconia surface before and after accelerated aging. Material and Methods: Forty samples of inCoris TZI were cut in the form of discs 15 mm (diameter) and 1mm (thickness) so that after sintering each disc dimensions' would be 12 mm (diameter) and 0.8 mm (thickness). All discs were colored by dipping in aqueous zirconia coloring solution of shade A2, then divided into four groups according to the type of surface treatment received before sintering; being tribochemical silica coating, zirconia powder deposition, glass grading, and a control untreated group. After sintering, all discs were veneered with a layer of porcelain 0.7 mm (thickness) and 12 mm (diameter). (ΔE) and TP were measured using VITA Easyshade Compact spectrophotometer before and after accelerated autoclave aging. Results: Different surface treatments applied had significant effect (P<0.05) over ΔE and TP. Glass graded group showed the highest ΔE value and the least TP value among both un-aged and aged sub-groups. Conclusion: Different surface treatments applied affected the color and translucency negatively where the control untreated group showed the highest TP and the least color deviation from the A2 color parameters. On the other hand, accelerated autoclave aging had no effect over translucency or color. (AU)


Objetivo: Apesar da maior translucidez da Y-TZP nanocristalina em relação à Y-TZP convencional, ela não pode ser usada na região anterior da boca em sua forma totalmente anatômica, sem o recobrimento cerâmico para uma melhor estética. Este estudo avaliou a mudança de cor (ΔE)eoparâmetrodetranslucidez(PT)das restauraçõesde zircônia nano-cristalina em duas camadas após diferentes tratamentos de superfície, antes e após o envelhecimento. Material e Métodos: Quarenta amostras de inCoris TZI foram cortadas na forma de discos de 15 mm (diâmetro) e 1 mm (espessura) para que, após sinterização, cada diâmetro dos discos fosse de 12 mm (diâmetro) e 0,8 mm (espessura). Todos os discos foram corados por imersão em solução aquosa de zircônia corante da sombra A2, divididos em quatro grupos de acordo com o tipo de tratamento de superfície recebido antes da sinterização; sendo revestimento de sílica químico-química, deposição de pó de zircônia, jateamento de vidro e um grupo de controle sem tratamento. Após a sinterização, todos os discos foram revestidos com uma camada de porcelana de 0,7 mm (espessura) e 12 mm (diâmetro). ΔE e TP foram medidos usando o espectrofotômetro VITA Easyshade Compact antes e depois do envelhecimento em autoclave. Resultados: Diferentes tratamentos de superfície aplicados tiveram efeito significativo (P <0,05) sobre ΔE o e maior TP. valor O grupo com de ∆E e o menor jateamento de vidro valor de TP apresentou entre os subgrupos não envelhecidos e envelhecidos. Conclusão: Diferentes tratamentos de superfície aplicados afetaram negativamente a cor e a translucidez, onde o grupo controle sem tratamento apresentou o maior TP e o menor desvio de cor dos parâmetros de coloração A2. Por outro lado, o envelhecimento acelerado da autoclave não teve efeito sobre a translucidez ou a cor. (AU)


Subject(s)
Aging , Spectrophotometers , Color
12.
Rev. odontol. UNESP (Online) ; 47(5): 298-304, Sept.-Oct. 2018. tab
Article in English | LILACS, BBO | ID: biblio-985723

ABSTRACT

Introduction: In order to simplify the technique, reduce the time required for direct adhesive restorations, bulk-fill resin composites have been developed be applied in bulk placement up to 4 mm increments. Objective: Evaluating the color change (ΔE) and the microtensile bond strength (μTBS) of bulk fill resin composites (BFRC) to dentin after the immersion in regular beverages and the application of bleaching systems. Method: Forty-five human molar teeth were randomly distributed in three groups according to the filling material (n=15): Filtek Bulk Fill, Tetric N Ceram Bulk Fill and Filtek Z100. The restored teeth were immersed in coffee, wine and distilled water (n=5) for 72 hours. The color parameters were measured using a spectrophotometer, having as basis the CIE L*a*b*, before and after tooth staining and application of bleaching processes. Subsequently, the teeth were sectioned to obtain the specimens for the microtensile testing. The ΔE values were analyzed applying the Kruskal-Wallis and the Wilcoxon tests, and the μTBS values were analyzed applying the ANOVA and the Bonferroni tests (p<0.05). Result: There were no significant differences in the ∆E values when comparing the BFRCs to the conventional resin composite (CRC) in most of the experimental groups. The ∆E values did not present significant differences before and after the application of bleaching processes for all the tested resin composites. The BFRCs presented higher μTBS values than the CRC after exposure to distilled water, wine and bleaching agent. Conclusion: The studied BFRCs presented similar color stability to the CRC. The BFRCs presented higher bond strength to the dentin than the CTC in most of the evaluated conditions. The bleaching agent was not effective in whitening the stained restored teeth.


Introdução: Em busca de simplificar a técnica, reduzir o tempo requerido para as restaurações adesivas, resinas compostas bulk-fill (RCBF) estão sendo desenvolvidas para serem aplicadas em incrementos com espessura de até 4 mm. Objetivo: Avaliar a alteração de cor (ΔE) e resistência de união (μTBS) de RCBF a dentina após imersão em bebidas e aplicação de um sistema clareador. Método: Foram utilizados 45 dentes molares humanos que foram distribuídos aleatoriamente em três grupos de acordo com o material restaurador (n=15): Filtek Bulk Fill, Tetric N Ceram Bulk Fill e Filtek Z100. Os dentes restaurados foram imersos em café, vinho e água destilada (n=5) durante 72 horas. Os parâmetros de cor foram mensurados utilizando um espectrofotômetro, tendo como base o CIE L*a*b*, antes e após o manchamento e aplicação dos agentes clareadores. Consequentemente, os dentes foram seccionados para a obtenção de espécimes para o teste de microtração. Os valores de ΔE foram analisados aplicando os testes de Kruskal-Wallis e Wilcoxon e os valores de μTBS foram analisados aplicando ANOVA e o teste de Bonferroni (p<0,05). Resultado: Não houve diferença significante nos valores de ∆E quando as RCBFs foram comparadas a resina composta convencional (RCC) na maioria dos grupos experimentais. Os valores de ∆E não apresentaram diferença estatística antes e após a aplicação do agente clareador para todas as resinas testadas. As RCBFs demonstraram maiores valores de μTBS comparado a RCC após exposição a água destilada, vinho e agente clareador. Conclusão: As RCBFs demonstraram uma similar estabilidade de cor quando comparado a RCC. As RCBFs apresentaram maior resistência de união a dentina que a RCC na maioria das condições avaliadas. O agente clareador não foi efetivo no clareamento dos dentes restaurados.


Subject(s)
Humans , Tensile Strength , Tooth Bleaching , Spectrophotometers , Color , Composite Resins , Tooth Bleaching Agents , Analysis of Variance , Dentin , Molar
13.
Rev. odontol. UNESP (Online) ; 47(5): 333-339, Sept.-Oct. 2018. tab
Article in English | LILACS, BBO | ID: biblio-985722

ABSTRACT

Introduction: The color stability of resin cements, whether dual-pre-cured or photopolymerizable, as well as the color of the dental substrate, are fundamental for the aesthetic success of ceramic restorations, since the ceramic presents a high level of translucency due to its small thickness. Objective: The aim of this in vitro study was to evaluate the color of a resin cement light polymerized by different light sources and immersed in potentially staining beverages. Material and method: Were made 42 specimens of resin cement Variolink-Esthetic (2×6mm) (n=7), being half polymerized with LED light (F1) and half with Halogen light (F2). The specimens were stored in artificial saliva at 37 °C±1 °C. After 24 hours, they were polished with abrasive discs, and divided for the purpose of being submitted to the different solutions for 2 minutes per day, for 28 days, as follows: S1 - Coca-Cola; S2 - Red Wine; and S3 - Distilled Water (Control). Five color readouts were taken: T0 - initial; T1 - 7 days; T2 - 14 days; T3 - 21 days; and T4 - 28 days; with a spectrophotometer (Model SP62S). The color change data (ΔE*) were submitted to statistical analysis, ANOVA and Tukey (p≤0.05). Result: Analyzing the factor solution, S2 (5.89 (±0.02)), produced a higher ΔE* value than S1 (3.79 (±0.02)) and (S1), a higher value than S3 (1.41 (±0.02)). Analyzing the factor light source, F2 (4.05 (±0.12)), produced a higher ΔE* value than F1 (3.33 (±0.12)). When analyzing the factor time, ΔE* values were found to increase gradually over the course of time: T1(2.36 (±0.08)); T2(3.27 (±0.08)); T3(4.06 (±0.08)); and T4(5.09 (±0.08)). Conclusion: It was concluded that red wine produced a greater color change; Halogen light promoted highest degree of pigmentation; and the longer the time of immersion, the greater the color change of the material.


Introdução: A estabilidade de cor dos cimentos resinosos, sejam eles de presa dual ou fotopolimerizáveis, assim como a cor do substrato dental, são fundamentais para o sucesso estético das restaurações cerâmicas uma vez que a cerâmica apresenta alto nível de translucidez devido a sua pequena espessura. Objetivo: O objetivo deste estudo in vitro foi avaliar a cor de um cimento resinoso fotopolimerizado por diferentes fontes de luz e imersos em bebidas potencialmente corantes. Material e método: Foram confeccionados 42 espécimes do cimento resinoso Variolink-Esthetic (2×6mm) (n=7), sendo metade fotopolimerizado com luz LED (F1) e metade com luz Halógena (F2). Os espécimes foram mantidos em saliva artificial à 37 °C±1 °C. Após 24 horas, foram polidos com discos abrasivos e subdivididos para serem imersos 2 minutos por dia, durante 28 dias, nas diferentes soluções: S1 - Coca-Cola; S2 - Vinho Tinto; e S3 - Água destilada (controle). Foram realizadas 5 leituras de cor: T0 - inicial; T1 - 7 dias; T2 - 14 dias; T3 - 21 dias; e T4 - 28 dias; com auxílio de um espectrofotômetro (modelo SP62S). Os dados de alteração de cor (ΔE*) foram submetidos a análise estatística, ANOVA e Tukey (p≤0,05). Resultado: Analisando o fator solução, S2 (5,89 (±0,02)), proporcionou maior ΔE* que S1 (3,79 (±0,02)) e este (S1), maior que S3 (1,41 (±0,02)). Analisando o fator fonte de luz, F2 (4,05 (±0,12)), proporcionou maior ΔE* que F1 (3,33 (±0,12)). E analisando o fator tempo, obteve-se que ΔE* foi gradativamente aumentando no decorrer do tempo: T1(2,36 (±0,08)); T2(3,27 (±0,08)); T3(4,06 (±0,08)); e T4(5,09 (±0,08)). Conclusão: Conclui-se que o vinho tinto promoveu maior alteração de cor; a luz Halógena promoveu maior pigmentação e; quanto maior o tempo de imersão, maior alteração de cor do material.


Subject(s)
Saliva , In Vitro Techniques , Color , Resin Cements , Light-Curing of Dental Adhesives , Dental Restoration Repair , Light , Wine , Pigmentation , Spectrophotometers , Analysis of Variance , Coloring Agents
14.
Rev. odontol. UNESP (Online) ; 47(3): 137-142, maio-jun. 2018. tab
Article in Portuguese | LILACS, BBO | ID: biblio-961511

ABSTRACT

Introdução: Em uma sociedade de alta competitividade social, os padrões estéticos estão cada vez mais refinados e, dentro destes, a concepção e o desejo de se ter o sorriso perfeito aumentaram consideravelmente a busca pelos tratamentos dentários e, consequentemente, o desenvolvimento de materiais que possam propiciar tais resultados. O sucesso clínico de uma restauração engloba sua longevidade, do ponto de vista funcional, incluindo ausência de infiltrações, e sua função estética, por meio da manutenção de coloração e lisura superficial adequada. Objetivo: O presente trabalho busca analisar a alteração de cor de duas marcas de compósitos odontológicos nanoparticulados ‒ Z350 e Bulk Fill (3M ESPE) ‒ e dois sistemas de polimento ‒ Disco SofLex e Disco SofLex espiral emborrachado (3M ESPE) ‒, com as subdivisões em grupos controle (água destilada) e experimental (café), em um período de 21 dias. Material e método: Os espécimes foram confeccionados de modo padronizado e armazenados por sete dias em água deionizada a 37 °C, em estufa para análise da cor inicial, seguido do armazenamento nas respectivas soluções para a análise cromática, ao final do período de estudo, sendo ambas as análises realizadas através de espectrofotômetro (CM-700d, Konica Minolta, Osaka, Japão) e escala ΔE CIELAB. Resultado: Observou-se que ambas as resinas tiveram sua coloração alterada na presença do café, entretanto a resina Z350 apresentou maiores variações em comparação à Bulk Fill. Conclusão: Apesar de a solução corante café ser capaz de promover mudança de cor nas resinas estudadas, os sistemas de polimento, isoladamente, não apresentam efeito final sobre a alteração cromática desses materiais restauradores.


Introduction: In a highly social competitive society, aesthetic standards are increasingly refined as the conception and desire of a perfect smile considerably increased the search for dental treatment, with the developing of materials that could propitiate those results. Restorations clinical success includes its longevity, from the functional point of view, with no infiltrations, and aesthetic, through the color conservation and proper surface smoothness. Aim: This work analyzes the color change of two nanoparticulate resins: Z350 and Bulk Fill (3M ESPE) and two polishing systems: SofLex Disk and rubber spiral SofLex Disk (3M ESPE), divided in control group (deionized water) and experimental group (coffe), during 21 days. Material and method: The resin discs were prepared by a standardized mode and submerged in deionized water for 7 days at 37 °C in incubator before initial color evaluation, followed by the immersion in each solution to final color analysis. Both used a spectrophotometer (CM-700d, Konica Minolta, Osaka, Japan) and ΔE CIELAB scale. Result: It was seen that both resins presented color change when exposed to coffee, however the Z350 resin presented a greater variation compared to Bulk Fill resin. Conclusion: Although coffee is a dye solution, the polishing systems did not present any effect on chromatic alteration.


Subject(s)
Smiling , Spectrophotometers , Coffee , Color , Dental Restoration, Permanent , Esthetics, Dental , Coloring Agents
15.
Pesqui. bras. odontopediatria clín. integr ; 18(1): 4124, 15/01/2018. tab
Article in English | LILACS, BBO | ID: biblio-967061

ABSTRACT

Objective: To investigate the color matching of the composite resin used for repaired with initial composite resin restoration after the aging process. Material and Methods: After preparation of 30 composite resin samples, their color were determined using the spectrophotometer four times and the average was recorded. After the initial aging, the color of the samples was measured again. Then, the repair process was performed with an appropriate composite resin color for each sample and the aging process was performed again. After the second aging, the color of the initial and the repaired composite resins were measured. Then, the data were analyzed by paired T-test. The level of significance was set at 5%. Results: The color difference of the initial composite resin between before and after initial aging, as well as the color difference of repaired composite resins between before and after second aging, were significant (p<0.001). Also, after the second aging, the color difference between initial and repaired composite resin restoration were significant (p<0.001). Conclusion: The color matching of the repaired composite resin with the initial one is not acceptable. In this way, replacement of initial composite suggested instead of repaired.


Subject(s)
Tooth Bleaching/methods , Color , Composite Resins , Light-Curing of Dental Adhesives , Spectrophotometers/methods , Statistics, Nonparametric , Iran
16.
Rev. odontol. UNESP (Online) ; 46(5): 267-272, Sept.-Oct. 2017. ilus
Article in English | LILACS, BBO | ID: biblio-902670

ABSTRACT

Introduction: patients have been submitted to tooth bleaching during orthodontic treatment for aesthetic purposes or to anticipate the replacement of restorations after completion of the treatment. Objective: to evaluate the effectiveness of tooth bleaching under orthodontic brackets bonded with different materials. Material and method: a hundred bovine enamel blocks were divided into two groups, at-home and in-office tooth bleaching. In-office bleaching was subdivided into five groups (n = 10): HP (control - without brackets); SA(t) - brackets bonded with Transbond XT, without bleaching; SA(fm) - brackets bonded with Orthodontic Fill Magic, without bleaching; HP(t) - brackets bonded with Transbond XT subjected to bleaching; and HP(fm) - brackets bonded with Orthodontic Fill Magic subjected to bleaching. At-home bleaching followed the same treatments, only replacing the bleaching agent. Spectrophotometric assessment was used for tooth color determination at three moments: 1) before staining (baseline); 2) after staining; 3) after bonding the brackets and bleaching procedures. Data were submitted to ANOVA and analyzed by Tukey's test (p < 0.05). Result: For both types of bleaching, the control group had an effective bleaching action. Groups using Transbond XT presented greater bleaching potential among the groups with orthodontic accessory, but the bleaching action differed from the positive control. Groups using Orthodontic Fill Magic presented no bleaching action, resembling the negative control groups (artificial saliva). Conclusion: the orthodontic bracket impaired the effectiveness of the at-home and in-office bleaching treatment, regardless of the resin used for bonding.


Introdução: pacientes estão sendo submetidos ao clareamento durante tratamento ortodôntico com finalidade estética ou para antecipar a troca de restaurações após finalização do tratamento ortodôntico. Objetivo: avaliar a efetividade do clareamento dentário sob braquete ortodôntico fixado com diferentes materiais. Material e método: cem blocos de esmalte bovino foram divididos em dois grupos, clareamento de consultório e clareamento caseiro. O de clareamento de consultório foi subdividido em cinco (n=10): HP (controle - sem braquetes); SA(t) - braquetes fixados com Transbond XT, sem clareamento; SA(fm) - braquetes fixados com Fill Magic Ortodôntico, sem clareamento; HP(t) - braquetes fixados com Transbond XT submetidos ao clareamento e HP(fm) - braquetes fixados com Fill Magic Ortodôntico submetidos ao clareamento. O clareamento caseiro seguiu a mesma divisão descrita para o clareamento de consultório substituindo-se o agente clareador. Foram realizadas avaliações da cor através do espectrofotômetro nos tempos: 1) antes do manchamento (baseline); 2) após o manchamento; 3) após fixação dos braquetes e procedimentos clareadores. Os dados foram submetidos à ANOVA e diferenças analisadas através do teste de Tukey (p˂0,05). Resultado: Para os dois tipos de clareamento o grupo controle teve ação clareadora efetiva. Grupos fixados com Transbond XT apresentaram maior potencial clareador dentre os grupos que apresentaram acessório ortodôntico, mas com ação clareadora diferente do controle positivo. Grupos fixados com Fill Magic Ortodôntico não apresentaram ação clareadora, assemelhando-se aos grupos controle negativo (saliva artificial). Conclusão: o braquete ortodôntico prejudicou a efetividade do tratamento clareador caseiro e de consultório, independente da resina utilizada para a fixação.


Subject(s)
Cattle , Tooth Bleaching , Analysis of Variance , Orthodontic Brackets , Dental Materials , Spectrophotometers , Dental Bonding
17.
Rev. odontol. UNESP (Online) ; 46(4): 203-207, July-Aug. 2017. tab, ilus
Article in English | LILACS, BBO | ID: biblio-902660

ABSTRACT

Introduction: Light-cured resin cements are the first choice for the cementation of laminate veneers. Ideally, they should be biocompatible and offer minimum risks to patients. Objective: The aim of this study was to evaluate, in vitro, the cytotoxicity of three resin cements: Variolink II, Ivoclar Vivadent (C1), Allcem Veneer, FGM (C2), and Rely X Veneer, 3M ESPE (C3). Material and method: Twenty four samples of each of the cements were fabricated in a standardized metal mold, light activated, and transferred to a 96-well cell plate with culture of fibroblasts. After 24, 48, and 72h of incubation, cytotoxicity was assessed and cell viability was calculated by the methyl-thiazol-tetrazolium (MTT) colorimetric assay. Absorbance was measured at 570 nm using a microplate spectrophotometer. Result: The following results were found: Variolink II presented viability of 72.24% (SD 6.80) after 24h, 83.92% (SD 5.26) after 48h, and 92.77% (SD 5.59) after 72h; Allcem Veneer exhibited viability of 70.46% (SD 12.91) after 24h, 85.03% (SD 21.4) after 48h, and 70.46% (SD 12.91) after 72h; Rely X Veneer showed viability of 5.06% (SD 0.88) after 24h, 5.84% (SD 1.18) after 48h, and 6.99% (SD 1.34) after 72h. Conclusion: Under these testing conditions, Rely X Veneer presented significantly higher cytotoxicity compared with those of the other light-cured resin cements assessed.


Introdução: Cimentos resinosos fotopolimerizáveis são materiais de eleição para a cimentação de facetas laminadas. Devem ser biocompatíveis oferencendo riscos mínimos ao uso clínico em pacientes. Objetivo: O objetivo desse trabalho foi avaliar in vitro a citotoxicidade de três cimentos resinosos: Variolink II (Ivoclar Vivadent), Allcem Veneer, (FGM) e Rely X Veneer (3M ESPE). Material e método: Vinte e quatro corpos de prova de cada cimento foram confeccionados em matrizes metálicas padronizadas e inseridos em placa de cultura de células de noventa e seis poços contendo fibroblastos da linhagem 3T3. As células foram cultivadas em meio de cultivo celular RPMI 1640 com 5% de soro fetal bovino, com 0,1% de penicilina/estreptomicina em estufa a 37◦C, em atmosfera úmida com 5% de CO2. O grau de citotoxicidade de cada cimento foi avaliado após os tempos de contato de 24h, 48h e 72h através do método MTT (3-(4,5-dimetiltiazol-2yl)-2,5- difenil brometo de tetrazolina), que avalia a viabilidade celular pela função mitocondrial. Após os tempos estabelecidos, as amostras foram removidas, tratadas e levadas ao espectofotômetro de microplaca para leitura da absorbância em 570nm. Resultado: O cimento Variolink apresentou em 24h viabilidade de 72,24% (±6,80), em 48h de 83,92% (± 5,26) e de 92,77% (±5,59) em 72h. Allcem Veneer apresentou viabilidade de 70,46% (± 12,91) em 24h; 85,03% (± 21,4) em 48h e 70,46% (± 12,91) em 72h. O RelyX Veneer demonstrou viabilidade de 5,06% (± 0,88) em 24h; 5,84% (± 1,18) em 48h e 6,99% (± 1,34) em 72h. Conclusão: Estes resultados demonstraram que o cimento Rely-X se apresentou significativamente mais citotóxico nas condições testadas.


Subject(s)
In Vitro Techniques , Cell Survival , Spectrophotometers , Composite Resins , Resin Cements , Dental Veneers
18.
Braz. j. oral sci ; 15(3)July-Sept. 2016. tab
Article in English | LILACS, BBO | ID: biblio-875034

ABSTRACT

Aim: This study investigated the effect of an in-office bleaching technique on lightness, color and surface roughness of two commercially available materials: a resin-modified glass-ionomer cement and a nanohybrid resin composite. Methods: Twelve disk-shaped specimens were prepared with both materials. The samples were bleached with 35% hydrogen peroxide. Bleaching was tested initially onto a smooth surface and later onto a polished one of the same specimens. The effect of the treatments on lightness and color was verified with a spectrophotometer. Surface roughness was measured with a digital surface roughness tester. The data were statistically analyzed by repeated measures ANOVA and post hoc Tukey's test (alpha = 0.05). Results: Significant variation in lightness and color was observed on the resin-modified glass-ionomer cement after the first bleaching procedure. Roughness increased significantly only after polishing the resin-modified glass-ionomer cement surface. Composite color variation was evident in the last observation period, but roughness and lightness variation due to bleaching and polishing was not significant. Conclusion: The bleaching treatment caused significant color alterations on the materials tested. This study observed that the application of in-office bleaching onto the glass-ionomer cement promoted clinically observable color alteration, and polishing after bleaching is contraindicated for this material. (AU)


Subject(s)
Composite Resins , Glass Ionomer Cements , Hydrogen Peroxide , Spectrophotometers , Tooth Bleaching
19.
Rev. odontol. UNESP (Online) ; 45(4): 195-200, July-Aug. 2016. tab, ilus
Article in English | LILACS, BBO | ID: lil-795233

ABSTRACT

Introduction: The staining of artificial teeth can be related to the acrylic resin abrasion caused by brushing, resulting in higher deposition of dyes from the beverage, and consequently higher aesthetic damage. Objective: The aim of this in vitro study was to evaluate methods for removal of stains from acrylic denture teeth using spectrophotometric analysis. Material and method: Artificial teeth were divided into twelve groups (n=10) according to the type of treatment (re-polishing - Re or immersion in Corega Tabs - Sp), staining solutions, coffee (Cf) and Coca-Cola® (Cc) or water (W) and with/without toothbrushing (B). The Sp specimens were submitted to seven immersion cycles (5 min each). The Re specimens were polished with pumice stone followed by Spain white paste. Color differences (ΔE) were captured by a spectrophotometer: T0 (baseline), T1 (after brushing/immersion in solutions) and T2 (after Re or Sp). Result: Statistically significant color change between T1 and T2 (paired T-test; α =.05) was observed for the group CfSp (p=.032); and for the groups BWRe (p=.000), BCfRe (p=.049) and CcRe (p=.042). Higher color changes were observed for the specimens submitted to toothbrushing (ANOVA two way; p<.001). Conclusion: It could be concluded that the immersion in sodium perborate (Corega Tabs) can be used for removal of coffee stains from denture teeth, and re-polishing for removal of Coca-Cola® stains. Still, toothbrushing produced greater color changes on denture teeth, regardless of the immersion solution.


Introdução: O manchamento dos dentes artificiais pode estar relacionado à abrasão da resina acrílica provocada pela escovação, resultando na maior deposição de corantes provenientes de bebidas, e consequentemente maior prejuízo estético. Objetivo: O objetivo do presente estudo foi avaliar métodos de remoção de manchas extrínsecas por meio de analise com espectofotômetro. Material e método: Dentes artificiais foram divididos em 12 grupos (n=10), de acordo com o tipo de tratamento (repolimento – Re ou imersão em perborato de sódio, Corega Tabs – Sp), tipo de solução de manchamento, café (Cf) ou Coca-Cola® (Cc) ou água (W) e com/sem escovação (B). Os métodos de remoção de manchas propostos (Re e Sp) foram realizados de acordo com protocolos pré-estabelecidos. Os espécimes Sp foram submetidos a 7 ciclos de imersão (5 minutos cada). O repolimento foi realizado com pastas de pedra pomes e branco de espanha, utilizando escovas de cerdas macias e rodas de feltro. As leituras de estabilidade de cor (ΔE) foram realizadas por meio de um espectrofotômetro: T0 (baseline), T1 (após escovação/imersão em bebidas), e T2 (após Re ou Sp). Resultado: Alterações de cor entre T1 e T2 (teste T pareado; α=0,05) foram observadas para o grupo CfSp (p=.032); e para os grupos BWRe (p=.000), BCfRe (p=.049) e CcRe (p=.042). Os dentes artificiais submetidos à escovação mostraram maior alteração de cor (ANOVA 2 fatores; p<0,001). Conclusão: Conclui-se que a imersão em perborato de sódio (Corega Tabs) pode ser utilizada para remoção de manchas de café e o repolimento para remoção de manchas de Coca-Cola®. Ainda, a escovação produziu as maiores alterações de cor nos dentes artificiais, independentemente da solução de imersão.


Subject(s)
Tooth, Artificial , Toothbrushing , Acrylic Resins , In Vitro Techniques , Color , Denture, Complete , Esthetics, Dental , Tooth Abrasion , Beverages , Spectrophotometers , Coffee , Coloring Agents
20.
Full dent. sci ; 7(25): 64-69, jan.2016. tab
Article in Portuguese | LILACS | ID: lil-790080

ABSTRACT

O objetivo deste estudo foi avaliar a correlação entre as cores nomeadas com identificações iguais de dentes artificiais de resina acrílica de diferentes marcas comerciais. Foram selecionadas cinco marcas: Vipi Dent Plus (VIPI), Biolux OMC (VIPI), Biocler G II (Dentbrás), Natus Dent (Dentbrás) e Tritone (VIPI), todas utilizando o mesmo padrão de nomenclatura. De cada marca comercial foram utilizadas as cores: 60, 62, 65, 66, 67 e 69. Para realizar as comparações de cor foi utilizado o aparelho espectrofotômetro Vita Easy Shade. Após três medições de cada cor, foi obtida a média das leituras, todas realizadas no centro do dente, no mesmo horário e com fundo cinza claro padronizado. Assim, os valores de L*, a* e b* foram obtidos. Esses valores foram tabulados para cálculos do ∆E, onde ∆E< ou = 3 representa diferença de cor significativa e perceptível. Observou-se correlação entre as marcas comerciais na cor 60 Biocler GII e Natus Dent (ΔE= 3); Biocler GII e Tritone (ΔE= 2,87), cor 62 Biolux OMC e Natus Dent (ΔE=1,33), cor 67 Natus Dent e Tritone (ΔE=2,06) e Tritone e Vipi Dent Plus (ΔE=1,92). Concluiu-se que os resultados demonstraram poucas correlações entre as marcas avaliadas e as correlações existentes não ocorreram de forma igual para todas as cores, dificultando o sucesso dos tratamentos protéticos, assim como a comunicação entre o cirurgião dentista e o técnico em prótese dentária...


The objective of this study was to evaluate the correlation between colors of artificial acrylic resin teeth from different brands with the same name and identification. Five brands were selected: Vipi Dent Plus (VIPI), Biolux WTO (VIPI), Biocler G II (Dentbrás), Natus Dent (Dentbrás), and Tritone (VIPI), all using the same naming pattern. The used colors from each brand were: 60, 62, 65, 66, 67, and 69. To perform comparisons of color the Vita Easy Shade spectrophotometer was used. After three measurements of each color a mean was obtained All readings were performed on the central area of the tooth, at the same time and with clear standard gray background, obtaining the values of L*, a*, and b*. These values were tabulated for ΔE calculations, where ΔE < or = 3 represented significant and noticeable color difference. There is a correlation between the trademarks in color 60 Biocler GII and Natus Dent (ΔE = 3); Biocler GII and Tritone (ΔE = 2.87), color 62 Biolux WTO and Natus Dent (ΔE = 1.33), color 67 Natus Dent and Tritone (ΔE = 2.06), and Tritone and Vipi Dent Plus (ΔE = 1, 92). It was concluded that the results showed little correlation between the evaluated brands and correlation did not occur equally to all colors, hindering the success of prosthetic treatments as well as communication between the dental surgeon and dental technician...


Subject(s)
Humans , Spectrophotometers/methods , Dental Prosthesis , Composite Resins/chemistry , Tooth, Artificial , Color