Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Añadir filtros








Intervalo de año
1.
Chinese Journal of Microbiology and Immunology ; (12): 200-204, 2014.
Artículo en Chino | WPRIM | ID: wpr-448029

RESUMEN

Objective To explore the expression of early growth response gene-1 (EGR-1) in T cells that were positive for Tax protein of human T-cell leukemia virus type 1 (HTLV-1) and its possible reg-ulatory mechanism .Methods A series of expression structures carrying the regulatory elements of EGR-1 in different length and luciferase reporter genes were constructed .TaxP cells were transfected with the con-structs containing reporter genes and cultured with 5μmol/L of NF-κB inhibitor BAY 11-7082 or equal vol-ume of DMSO.After cultured for 24 hours the cells were collected to test the luciferase activity .BAY 11-7082 or equal volume of DMSO was added into the supernatant of TaxP cell culture to test the expression of EGR-1 protein by Western blot after 24 hours of culture .Tax and its mutants M22 and M47 were transfected into 293 T cells respectively to test the expression of EGR-1 protein by Western blot after 24 hours of culture . Results The expression structures carrying the regulatory elements of EGR-1 in different length and their mutants followed by luciferase reporter genes were successfully constructed .The luciferase activity in the cells transfected with the constructs containing the elements E 1 and E2 were higher than that transfected with E3, DelE and MutE, but the reporter gene expressions were decreased with the interference of BAY 11-7082 (P<0.01).However, there were no significant changes with the luciferase activity in the cells transfected by elements E3, DelE and MutE.Western blot analysis indicated that the expression of EGR-1 protein was significantly decreased with the interference of BAY 10-7082 .The expression of EGR-1 protein in M22 mu-tants-transfected 293 T cells were decreased significantly in comparison with those by wild type tax-and M47-transfected cells .Conclusion NF-κB was the key nuclear factor in regulating the expression of EGR-1 pro-tein in Tax-positive T cells .

2.
International Journal of Biomedical Engineering ; (6): 172-175,后插2, 2010.
Artículo en Chino | WPRIM | ID: wpr-540789

RESUMEN

Objective To explore the feasibility of clinical application of biodegradable polymer-coated drug-eluting stent. Methods Thirty each of the drug-eluting stent or bare-metal stents were implanted randomly into the anterior descending arteries, circumflex and right canine coronary arteries of thirty healthy pigs. The pathological examination was taken at 2 weeks to 6 months after coronary angiography to investigate the inflammation, thrombosis and endothelialization. Results Macroscopic observation of the stented arteries demonstrated complete incorporation of stent wires into the arterial wall and smooth vessel lumens. There were no significant differences existing between two kinds of the stents in terms of thrombosis, inflammation and endothelialization. The lumen loss in the biodegradable polymer-coated drug-eluting stent group is less than that in the bare-metal stent group. Conclusion The biodegradable polymer-coated drug-eluting stent is promising with good biocom-patibility, blood compatibility and phyaicochemical stability after being implanted into pig coronary arteries. The blood vessel transplanted with the drug-eluting stents maintains a high patency rate due to rapid endothelialization.

3.
Chinese Journal of Tissue Engineering Research ; (53): 7675-7678, 2009.
Artículo en Chino | WPRIM | ID: wpr-405776

RESUMEN

To make a portable apparatus for the patient self-doing joint voluntarily exercise that is keeping with the training demand of human body potential and muscle strong. Different kinds of spring belts are used for joint exercise apparatus according to the needs of joint exercise. Though active joint extension and flexion by using the method of Chinese physical and breathing exercises, the exercise was done by drawing the spring belt. The extremity multifunctional training box is easy for carrying and sutble for each mussel be trained. Because of the wide range of back spring power, it is easy to reach the best training mount and to do the continually training under the biggest training mount. It is beneficial to the joint active function improvement. From June 2006 to February 2008, this kind of apparatus was used in 30 patients with footdrop at the Beijing Tongren Hospital, Capital Medical University. The design of the extremity multifunctional training box is reasonable, and it is easy for carrying and operating. It is also helpful for the patient to do muscle exercise themselves, and the joint function can be persisted and improved by continual exercise using this apparatus.

4.
Chinese Journal of Tissue Engineering Research ; (53): 9455-9458, 2009.
Artículo en Chino | WPRIM | ID: wpr-404642

RESUMEN

A device for promoting normal locomotor activity recuperation was made, which was composed by frame, elastic bolt and normal gait mark carpet. The device has the effects of weight relieving, abnormal gait preventing, and safeguards providing. The patient could do gait training by he/her self or assistant self training under the weight reducing and protecting of the device in order to improve the walking ability and the normal gait formation. It is effective for preventing drop foot and leg adduction, and also helpful for the recovery of normal gait ability and the prevention of abnormal gait formation. It is applicable for the patient who can not be trained with ordinary weight relief walking training, such as severe cerebral palsy and severe spasmodic lower extremity and foot drop after brain injury. The results demonstrated that the device is effective in protecting, correcting, preventing abnormal gait as well as forming normal gait.

5.
Chinese Journal of Rehabilitation Theory and Practice ; (12): 922-924, 2008.
Artículo en Chino | WPRIM | ID: wpr-972064

RESUMEN

@#Objective To develop one kind of device that can not only reduce the body weight,but also provide a good condition for training lower extremity potentialities.Methods The body weight bearing support and protection system,body weight reducing system and scaled footboard were made respectively.The lower extremity potentialities,nervous conduction speed and leg motion coordination ability training were done under protection and body weight reducing.Results The potential training device could exactly protect the patient and reduce body weight,and make the training step by step.Under the effects of protecting and body weight reducing of the potential training device,the training could be performed together with the Chinese traditional medicine rehabilitation method;that was physical and breathing exercises.The lower extremity potentialities were developed nicely.Conclusion The lower extremity potentialities training device is a useful training device which can bear body weight,have protective effect,develop lower extremity potentialities and improve coordination ability of lower extremities.

6.
Chinese Journal of Rehabilitation Theory and Practice ; (12): 922-924, 2008.
Artículo en Chino | WPRIM | ID: wpr-972060

RESUMEN

@#Objective To develop one kind of device that can not only reduce the body weight,but also provide a good condition for training lower extremity potentialities.Methods The body weight bearing support and protection system,body weight reducing system and scaled footboard were made respectively.The lower extremity potentialities,nervous conduction speed and leg motion coordination ability training were done under protection and body weight reducing.Results The potential training device could exactly protect the patient and reduce body weight,and make the training step by step.Under the effects of protecting and body weight reducing of the potential training device,the training could be performed together with the Chinese traditional medicine rehabilitation method;that was physical and breathing exercises.The lower extremity potentialities were developed nicely.Conclusion The lower extremity potentialities training device is a useful training device which can bear body weight,have protective effect,develop lower extremity potentialities and improve coordination ability of lower extremities.

7.
China Pharmacy ; (12)2005.
Artículo en Chino | WPRIM | ID: wpr-532583

RESUMEN

OBJECTIVE: To establish a RP-HPLC method for the determination of the content of hesperidin in Yangweishu tablets.METHODS: The samples were separated on octadecyl silane bonded gel silica column(150 mm?4.6 mm,5 ?m) with the mobile phase consisted of methanol-7% acetic acid solution(32∶68) under a detection wavelength of 283nm.RESULTS: The linear range of hesperidin was 49.6~892.8 ng(r=0.999 9) with an average recovery rate of 99.02%(RSD=0.45%,n=9).CONCLUSION:The method is simple,accurate,reproducible and applicable for the quality control of Yangweishu tablets.

8.
China Pharmacy ; (12)2005.
Artículo en Chino | WPRIM | ID: wpr-532336

RESUMEN

OBJECTIVE:To optimize the extraction technology of Zishen yangyin granules.METHODS:The yield of the extractum and the content of the extraction using 80% alcohol as solvent were used as indexes to optimize the extraction technology of Zishen yangyin granules by orthogonal experiment with the times of extraction,the extraction time and the amount of water added as factors.RESULTS:The optimal extraction conditions were as follows:the extraction was carried out for 3 times by adding water at an amount of 9 times,6 times and 6 times,respectively that of solid substance with decoction time of 3 h,2 h and 1 h,respectively.CONCLUSION:The optimal extraction process was proved to be time-saving and energy-saving and suitable for large production.

9.
Chinese Traditional and Herbal Drugs ; (24)1994.
Artículo en Chino | WPRIM | ID: wpr-580195

RESUMEN

Objective To observe the effect of the different bore diameter membranes on technological parameters of Radix Polygoni Multiflori Granula and to optimize the process of membrane filtration.Methods Three different membranes were tested under different parameters of operation to observe the changes in membrane flux and the content of effective components by Radix Polygoni Multiflori Granula.Results The membrane(50 nm)had the great flux,the transfering rate of stilbene glucoside was the highest;The optimum conditions:the operation differential pressure was 0.8-1.2 MPa;The operation temperature was 50-60 ℃;the membrane surface flow rate was 3.0 m/s.When the volume of filtration solution was condensed to 1/10 of former,entering the same volume deionized water into it,and when the effective components transfering rate reached 80%,the filtration was finished.Using the strong acid and strong alkali to wash it in turn,the flux could revive above 90%.Conclusion It can be obtained a good result that adopts the technology of ceramic membranes microfiltration to refine Radix Polygoni Multiflori Granula.This can provide the foundation for the application of ceramic membrane microfiltration in the refinement of water extraction of other Chinese materia medica.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA