Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Añadir filtros








Intervalo de año
1.
Rev. chil. obstet. ginecol ; 76(1): 15-20, 2011. tab
Artículo en Español | LILACS | ID: lil-627382

RESUMEN

INTRODUCCIÓN: Los dispositivos intrauterinos (DIU) son métodos de anticoncepción reversible, ampliamente usados en el mundo. Se estima que 120 millones de mujeres usan un DIU en el mundo como método anticonceptivo. OBJETIVO: Evaluar los factores de riesgo que puedan relacionarse con una incorrecta inserción del DIU. MÉTODO: 93 pacientes de un Centro de Salud Familiar de la ciudad de Talca, Chile. Utilizando tablas de contingencia se calcularon diferentes medidas de asociación y se compararon los casos de DIU mal posicionado con los casos con uno o más factores de riesgo identificados. RESULTADOS: Se encontró una incidencia de DIU incorrectamente posicionado de un 15,8%, de los cuales hubo un 2,1% de perforación uterina, 2,1% para DIU incrustado y 11,8% para DIU descendido. Se identificaron como factores de riesgo de DIU incorrectamente posicionado la cicatriz de cesárea (RR: 2,31), inserción dificultosa (RR: 3,31) y opinión de un resultado dudoso (RR: 3,64), con una sensibilidad de 73,3%. CONCLUSIONES: La ecotomografía transvaginal es una herramienta crucial para la confirmación de una correcta inserción del DIU y debería ser un examen de rutina ante la presencia de cualquiera de los factores de riesgo identificados.


BACKGROUND: Intrauterine devices (lUDs) are reversible birth control methods that are widely used throug-hout the world. It is estimated that 120 million women use an IUD in the world as a contraceptive. AIM: To assess the risk factors that may relate to incorrect insertion of the IUD. METHODS: The sample included 93 patients of a Family Health Center, Talca, Chile. Using contingency tables, various measures of association were calculated, and the cases of incorrectly positioned IUD were compared with the cases where one or more risk factors were identified. RESULTS: We found an incidence of 15.8% of incorrectly positioned IUD, of which 2.1% presented with uterine perforation, 2.1% with embedment of the IUD and 11.8% with a descended IUD. We identified the following risk factors for incorrectly positioned IUD: cesarean section (RR: 2.31), difficulty on insertion (RR: 3.31) and practitioner's opinión of an uncertain result (RR: 3.64), with a sensitivity of 73.3%. CONCLUSIONS: Transvaginal ultrasound is a crucial tool for confirmation of proper insertion of an IUD and should be considered a routine examination when any of the identified risk factors are present.


Asunto(s)
Humanos , Femenino , Atención Primaria de Salud , Ultrasonografía/métodos , Dispositivos Intrauterinos/efectos adversos , Vagina , Chile , Incidencia , Factores de Riesgo , Estudios de Cohortes , Migración de Cuerpo Extraño/diagnóstico por imagen
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA