Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Añadir filtros








Intervalo de año
1.
Annals of the Academy of Medicine, Singapore ; : 686-694, 2021.
Artículo en Inglés | WPRIM | ID: wpr-887558

RESUMEN

INTRODUCTION@#Acute respiratory distress syndrome (ARDS) in COVID-19 is associated with a high mortality rate, though outcomes of the different lung compliance phenotypes are unclear. We aimed to measure lung compliance and examine other factors associated with mortality in COVID-19 patients with ARDS.@*METHODS@#Adult patients with COVID-19 ARDS who required invasive mechanical ventilation at 8 hospitals in Singapore were prospectively enrolled. Factors associated with both mortality and differences between high (<40mL/cm H@*RESULTS@#A total of 102 patients with COVID-19 who required invasive mechanical ventilation were analysed; 15 (14.7%) did not survive. Non-survivors were older (median 70 years, interquartile range [IQR] 67-75 versus median 61 years, IQR 52-66; @*CONCLUSION@#COVID-19 ARDS patients with higher compliance on the day of intubation and a longitudinal decrease over time had a higher risk of death.


Asunto(s)
Humanos , COVID-19 , Rendimiento Pulmonar , Fenotipo , Síndrome de Dificultad Respiratoria del Recién Nacido/terapia , SARS-CoV-2
2.
Annals of the Academy of Medicine, Singapore ; : 467-473, 2021.
Artículo en Inglés | WPRIM | ID: wpr-887514

RESUMEN

INTRODUCTION@#Despite adhering to criteria for extubation, up to 20% of intensive care patients require re-intubation, even with use of post-extubation high-flow nasal cannula (HFNC). This study aims to identify independent predictors and outcomes of extubation failure in patients who failed post-extubation HFNC.@*METHODS@#We conducted a multicentre observational study involving 9 adult intensive care units (ICUs) across 5 public hospitals in Singapore. We included patients extubated to HFNC following spontaneous breathing trials. We compared patients who were successfully weaned off HFNC with those who failed HFNC (defined as re-intubation ≤7 days following extubation). Generalised additive logistic regression analysis was used to identify independent risk factors for failed HFNC.@*RESULTS@#Among 244 patients (mean age: 63.92±15.51 years, 65.2% male, median APACHE II score 23.55±7.35), 41 (16.8%) failed HFNC; hypoxia, hypercapnia and excessive secretions were primary reasons. Stroke was an independent predictor of HFNC failure (odds ratio 2.48, 95% confidence interval 1.83-3.37). Failed HFNC, as compared to successful HFNC, was associated with increased median ICU length of stay (14 versus 7 days, @*CONCLUSION@#Post-extubation HFNC failure, especially in patients with stroke as a comorbidity, remains a clinical challenge and predicts poorer clinical outcomes. Our observational study highlights the need for future prospective trials to better identify patients at high risk of post-extubation HFNC failure.


Asunto(s)
Adulto , Femenino , Humanos , Masculino , Persona de Mediana Edad , Extubación Traqueal , Cánula , Cuidados Críticos , Unidades de Cuidados Intensivos , Insuficiencia Respiratoria/terapia , Singapur/epidemiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA