Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Artículo en Inglés | WPRIM | ID: wpr-211470

RESUMEN

PURPOSE: This in vitro study investigated and compared the durability and retention of three types of attachments. MATERIALS AND METHODS: Three commercially available attachments were investigated: Clix(R), Dalbo-Plus(R) and Locator(R). In total, 72 samples of these attachments were placed in the acrylic resin forms and subjected to mechanical testing (5400 cycles of insertion and removal) over the respective ball or Locator abutments immersed in artificial saliva at pH 7 and 37degrees C. The abutments were placed at angulations of 0degrees, 10degrees and 20degrees. The retention force was recorded at the beginning and after 540, 1080, 2160, 3240, 4320 and 5400 insertion-removal cycles. RESULTS: The results revealed that there were significant differences in the average values of the insertion/removal force due to angulation (F (2.48) = 343619, P<.05) and the type of attachment (F (7.48) = 23.220, P<.05). CONCLUSION: Greater angulation of the abutments was found to influence the retention capacity of the attachments, and the fatigue test simulating 5 years of denture insertion and removal did not produce wear in the metal abutments.


Asunto(s)
Implantes Dentales , Prótesis de Recubrimiento , Dentaduras , Fatiga , Concentración de Iones de Hidrógeno , Saliva Artificial
2.
Artículo en Inglés | WPRIM | ID: wpr-225520

RESUMEN

OBJECTIVE: To quantify, for each activation, the effect of preactivations of differing distribution and intensity on the neutral position of T-loops (7-mm height), specifically the horizontal force, moment to force (M/F) ratio, and load to deflection ratio. METHODS: A total 100 loops measuring 0.017 x 0.025 inches in cross-section were divided into two groups (n = 50 each) according to composition, either stainless steel or beta-titanium. The two groups were further divided into five subgroups, 10 loops each, corresponding to the five preactivations tested: preactivations with occlusal distribution (0degrees, 20degrees, and 40degrees), gingival distribution (20degrees), and occlusal-gingival distribution (40degrees). The loops were subjected to a total activation of 6-mm with 0.5-mm iterations. Statistical analysis was performed using comprised ANOVA and Bonferoni multiple comparison tests, with a significance level of 5%. RESULTS: The location and intensity of preactivation influenced the force intensity. For the M/F ratio, the highest value achieved without preactivation was lower than the height of the loop. Without preactivation, the M/F ratio increased with activation, while the opposite effect was observed with preactivation. The increase in the M/F ratio was greater when the preactivation distribution was partially or fully gingival. CONCLUSIONS: Depending on the preactivation distribution, displacement of uprights is higher or lower than the activation, which is a factor to consider in clinical practice.


Asunto(s)
Análisis de Varianza , Acero Inoxidable
3.
Artículo en Inglés | WPRIM | ID: wpr-220556

RESUMEN

PURPOSE: The aim of this study was to compare the durability and retention of 4 types of attachments placed over computer aided design/computer aided manufacturing (CAD/CAM) titanium bars when subjected to different pH conditions. MATERIALS AND METHODS: Four commercially available attachments were investigated: Hader Yellow, Hader Red, Ackerman Gold and Ackerman Stainless Steel. These attachments and Ackerman CAD/CAM titanium bars were placed in 2 vessels containing different artificial saliva solutions (pH 7/pH 4) at 37degrees C for one month to simulate corrosion conditions, and they were then subjected to mechanical testing (5400 cycles of insertion and removal). RESULTS: The results revealed that there were significant differences in the average values of insertion/removal force due to the pH (F (1, 24)=9.207, P<.05) and the type of attachment (F (3, 24)=11.742, P<.05). CONCLUSION: More acidic pH values were found to have a negative influence on the retention capacity of the attachments.


Asunto(s)
Corrosión , Implantes Dentales , Prótesis de Recubrimiento , Concentración de Iones de Hidrógeno , Saliva , Saliva Artificial , Acero Inoxidable , Titanio
4.
Saúde Soc ; 22(2): 351-364, abr.-jun. 2013. tab
Artículo en Portugués | LILACS, SES-SP | ID: lil-684171

RESUMEN

A atual ampliação dos fluxos migratórios internacionais coloca em debate a responsabilização dos Estados pela garantia de direitos sociais básicos às populações imigrantes, dentre eles, o acesso à saúde. Este trabalho busca contribuir para a compreensão do Brasil neste novo quadro, por meio de uma pesquisa qualitativa sobre o acesso à saúde de imigrantes recentes na cidade de São Paulo. Foram realizadas vinte e três entrevistas em profundidade com imigrantes bolivianos, por meio de um roteiro semiestruturado. A intermitente insatisfação dos brasileiros quanto ao atendimento prestado pelo Sistema Único de Saúde no Brasil torna surpreendente a constatação de que, entre os bolivianos entrevistados, os serviços de saúde a que têm acesso são positivamente valorizados, ao contrário do que ocorre em seu próprio país de origem. Tal avaliação positiva só pode ser compreendida se analisada sua condição de imigrantes de primeira geração. Revelou-se fundamental compreender a perspectiva comparativa Brasil-Bolívia, utilizada pelos entrevistados para avaliar o acesso à saúde em São Paulo. Para contextualizar os dados coletados, foram delineados os principais componentes institucionais dos sistemas de saúde nos dois países e apresentado um conjunto sistematizado de dados macrossociais comparativos entre Brasil e Bolívia. Nas considerações finais, discutimos em que medida as experiências relatadas reafirmam ou não as principais teses apresentadas na literatura, à luz dos achados da pesquisa de campo. Destaca-se o papel desempenhado pelos proprietários das oficinas e pelos agentes comunitários de saúde, que aparecem como elementos facilitadores do acesso, além das redes familiares e de conacionais.


Asunto(s)
Humanos , Accesibilidad a los Servicios de Salud , Acceso Universal a los Servicios de Salud , Emigración e Inmigración , Sistemas de Salud , Recolección de Datos , Entrevistas como Asunto , Investigación Cualitativa
5.
Estud. av ; Estud. av;20(57): 41-54, maio-ago. 2006. ilus
Artículo en Portugués | LILACS | ID: lil-433588

RESUMEN

As remessas contribuem para o desenvolvimento local e para redução da pobreza? Essa é a pergunta-chave que os estudos recentes sobre migrações internacionais têm levantado. O que se está procurando compreender é de que modo as remessas poderiam afetar positiva ou negativamente a economia dos países de origem dos imigrantes. Discutir o papel e o significado das remessas implica, assim, uma discussão em torno da existência (ou não) de um "campo de positividades" do fenômeno migratório internacional. O principal objetivo deste artigo é contribuir para essa discussão por meio de um estudo empírico do caso brasileiro que adota as remessas como foco. Para tanto, é identificado o perfil das remessas e dos remetentes, assim como os objetivos e os beneficiários do dinheiro enviado. A pesquisa usa uma abordagem baseada em entrevistas em profundidade e survey não-representativo (Boston e Governador Valadares).


Asunto(s)
Economía , Emigración e Inmigración , Brasil
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA