Rev. bras. hematol. hemoter ; 31(3): 153-159, 2009. ilus, graf, tab
Artículo en Portugués | LILACS | ID: lil-523134

RESUMEN

Foi investigada a viabilidade da aplicação da técnica de fluorescência de raios X (XRF) como alternativa para acompanhamento dos níveis de ferro em pacientes portadores de talassemia maior (beta-thalassemia) e hemocromatose hereditária (HH). As medidas foram realizadas no Hemocentro do Hospital Universitário e no Laboratório de Física Nuclear Aplicada da Universidade Estadual de Londrina. Foi acompanhada uma portadora de talassemia maior e quatro pessoas sadias. Foi utilizado um sistema portátil de XRF constituído de uma fonte de Raios X de 238Pu e um detector de SiPIN diodo, para as medidas in vivo na mão. O sistema foi calibrado medindo simulados de solução aquosa com 15 a 150 ppm de ferro. A duração de cada medida foi de 50 s. O limite de detecção (LLD) atingido foi de 13 ppm de ferro. A dose de radiação na pele foi de 10 mSv. A paciente de talassemia apresentou 74 ± 6 ppm de ferro, enquanto pessoas sadias apresentaram valor médio de 53 ± 5 ppm de ferro. Os resultados estão de acordo com a literatura, que informa níveis de ferro na pele de 15 a 60 ppm em pessoas sadias e de 70 a 150 ppm em pacientes portadores da talassemia maior. Foi concluído ser viável a aplicação da XRF para acompanhamento de pacientes de talassemia maior e HH.


The viability of the X-ray fluorescence technique as an alternative to follow up iron levels in patients suffering from thalassemia major (beta-thalassemia) and hereditary hemochromatosis was investigated. The measurements were carried out in the University Hospital Blood Center and in the Laboratory of Applied Nuclear Physics of the State University of Londrina. One thalassemia major patient and four healthy individuals were enrolled in the study. A portable X-ray fluorescence system consisting in a 238Pu X-ray source and a Si PIN diode detector was used for in vivo measurements of the hand. The system was calibrated using 15 to 150 ppm concentrations of iron in an aqueous solution. The duration of each measurement was 50 seconds. The achieved detection limit was 13 ppm of iron. The radiation dose on the skin was 10 mSv. The thalassemia patient presented with 74 ± 6 ppm of iron, whereas the healthy individuals presented with an average of 53 ± 5 ppm of iron. The results are in accordance with prior publications that reported iron levels in the skin of between 15 and 60 ppm in healthy people and between 70 and 150 ppm in thalassemia major patients. In conclusion the X-ray Fluorescence technique is viable in the follow- up of thalassemia major and Hereditary Hemochromatosis patients.


Asunto(s)
Humanos , Talasemia beta , Fluorescencia , Hemocromatosis , Sobrecarga de Hierro , Mediciones Luminiscentes
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA