Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Añadir filtros








Intervalo de año
1.
Rev. bras. ortop ; 58(3): 507-513, May-June 2023. tab, graf
Artículo en Inglés | LILACS | ID: biblio-1449817

RESUMEN

Abstract Objective To evaluate the biomechanical capacity of two forms of fixation for Pipkin type-II fractures, describing the vertical fracture deviation, the maximum and minimum principal stresses, and the Von Mises equivalent stress in the syntheses used. Materials and Methods Two internal fasteners were developed to treat Pipkin type-II fractures through finite elements: a 3.5-mm cortical screw and a Herbert screw. Under the same conditions, the vertical fracture deviation, the maximum and minimum principal stresses, and the Von Mises equivalent stress in the syntheses used were evaluated. Results The vertical displacements evaluated were of 1.5mm and 0.5mm. The maximum principal stress values obtained in the upper region of the femoral neck were of 9.7 KPa and 1.3 Kpa, and the minimum principal stress values obtained in the lower region of the femoral neck were of-8.7 KPa and -9.3 KPa. Finally, the peak values for Von Mises stress were of 7.2 GPa and 2.0 GPa for the fixation models with the use of the 3.5-mm cortical screw and the Herbert screw respectively. Conclusion The fixation system with the Herbert screw generated the best results in terms of reduction of vertical displacement, distribution of the maximum principal stress, and the peak Von Mises equivalent stress, demonstrating mechanical superiority compared to that of the 3.5-mm cortical screw in the treatment of Pipkin type-II fractures.


Resumo Objetivo Avaliar a capacidade biomecánica de duas formas de fixação de fraturas tipo II de Pipkin descrevendo o desvio da fratura no sentido vertical, as tensões máxima e mínima principais, e a tensão equivalente de Von Mises nas sínteses utilizadas. Materiais e Métodos Dois fixadores internos foram desenvolvidos para tratar a fratura tipo II de Pipkin por meio de elementos finitos: parafuso cortical de 3,5 mm e parafuso de Herbert. Sob as mesmas condições, foram avaliados o desvio da fratura no sentido vertical, as tensões máxima e mínima principais, e a tensão equivalente de Von Mises nas sínteses utilizadas. Resultados Os deslocamentos verticais avaliados foram de 1,5 mm e 0,5 mm. Os valores de tensão máxima obtidos na região superior do colo femoral foram de 9,7 KPa e 1,3 KPa, e os valores de tensão mínima obtidos na região inferior do colo femoral foram de -8,7KPa e -9,3 KPa. Por fim, os valores de pico da tensão equivalente de Von Misesforam de 7,2 GPa e2,0 GPa paraosmodelos de fixação com o uso do parafuso cortical de 3,5 mm e do parafuso de Herbert, respectivamente. Conclusão Osistema de fixação com parafuso de Herbert gerou os melhores resultados em termos de redução do deslocamento vertical, distribuição da tensão máxima e do pico da tensão equivalente de Von Mises, o que demonstra sua superioridade mecânica comparada à do parafuso cortical de 3,5 mm no tratamento da fratura tipo II de Pipkin.


Asunto(s)
Humanos , Tornillos Óseos , Cabeza Femoral/cirugía , Fracturas de Cadera/cirugía
2.
Acta ortop. bras ; 30(2): e241045, 2022. tab, graf
Artículo en Inglés | LILACS-Express | LILACS | ID: biblio-1374139

RESUMEN

ABSTRACT Objective: This study aims to describe a simple and accurate semiological method executing a specific maneuver with the lower limb to direct the semiological investigation towards the tendinopathies in the gluteus medius and minimus. Methods: Fifty patients participated in the study, with a mean age of 44.1 ± 13 years, with persistent pain on the side of the hip for more than three months. To compare the FABREX (proposed test) and Lequesne semiological tests, in the diagnosis of tendinopathies in the gluteus medius and minimus, Magnetic Resonance Imaging (MRI) was adopted as the gold standard. Results: FABREX presented high sensitivity and moderate specificity for tendinopathy in the gluteus medius and high sensitivity and specificity for tendinopathy in the gluteus minimus. Conclusion: The proposed test, when positive, can be used to determine the diagnosis of gluteal tendinopathies (high specificity). Moreover, it has high sensitivity, excluding the diagnosis when negative. This study represents the initial step for validating the FABREX test, and can therefore be considered a simple and accurate procedure to identify patients with or without gluteal tendinopathies. Level of Evidence III, Case Control Study.


RESUMO Objetivo: Esse estudo propõe descrever um método semiológico simples e acurado, por meio de uma manobra específica com o membro inferior, a fim de direcionar a investigação semiológica para as tendinopatias dos glúteos médio e mínimo. Métodos: Participaram do estudo 50 pacientes, com média de idade de 44,1 ± 13,0 anos, apresentando dor persistente na face lateral do quadril há mais de 3 meses. A RM foi adotada como padrão ouro, para fins de comparação entre as duas manobras semiológicas (FABREX (teste proposto) e teste de Lequesne) no diagnóstico das tendinopatias do glúteo médio e mínimo. Resultados: O FABREX apresentou alta sensibilidade e moderada especificidade para tendinopatia de glúteo médio e alta sensibilidade e especificidade para tendinopatia do glúteo mínimo. Conclusão: A manobra proposta, quando positiva, pode ser utilizada para determinar o diagnóstico de tendinopatias glútea (alta especificidade). Além disso, possui alta sensibilidade, descartando o diagnóstico quando negativa. O presente trabalho constitui o passo inicial para validação do teste de FABREX, podendo assim, ser considerado um procedimento simples e acurado para identificar pacientes com ou sem tendinopatias glúteas. Nível de Evidência III, Estudo de Caso Controle.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA