Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Biosci. j. (Online) ; 39: e39037, 2023. ilus, tab
Artículo en Inglés | LILACS | ID: biblio-1428172

RESUMEN

This study evaluated the effects of ultrasonic activation (US) associated to glycolic acid (GA) on smear layer, dentin structure and bond strength (BS) of filling/restorative material to root dentin. The roots were used for antimicrobial activity, dentin structure and BS evaluation, being distributed into seven groups, according to irrigation protocols: G1:DW+US; G2:17% EDTA; G3:QMix; G4:17% GA; G5:17% EDTA+US; G6:QMix+US; G7:17% GA+US. Scanning electronic microscopy, transmission electronic microscopy and push-out were performed, with specific statistical analysis for each evaluation. The highest smear layer removal occured in Groups 6 and 7 (p<0.05), and the largest collagen dispersion in Group 7, being similar to Group 2 and 5 (p>0.05). The highest BS of filling and restorative material occurred in Groups 6 and 7, and Groups 5, 6 and 7, respectively, being similars between them (p>0.05). The use of GA+US promoted effective smear layer removal and dentin structure preservation, improving the BS of filling/restorative material to root dentin.


Asunto(s)
Ácidos , Ácido Edético , Endodoncia
2.
Braz. dent. j ; 33(2): 91-98, Mar.-Apr. 2022. tab, graf
Artículo en Inglés | LILACS-Express | LILACS, BBO | ID: biblio-1374624

RESUMEN

Abstract This study aimed to evaluate the influence of calcium silicate-based sealers on the bond strength of fiber posts using conventional and self-adhesive resin cement. Sixty single-rooted teeth were selected. The canals were prepared with a reciprocating instrument 40.06. The roots were randomly distributed in six groups (n = 10) according to the strategies for root canal filling and fiber posts cementation: AH Plus/RelyX ARC; AH Plus/RelyX U200; Bio C Sealer/RelyX ARC; Bio C Sealer/RealyX U200; Sealer Plus BC/RelyX ARC; and Sealer Plus BC/RelyX U200. The roots were transversally sectioned, and one slice per post-third was obtained. The push-out test was performed at a crosshead speed of 1mm/min. The failure patterns were described after assessment with a stereomicroscope with a 10× magnification. Bond strength was calculated and analyzed using the ANOVA and Tukey test. AH Plus did not influence the bond strength of fiber posts cemented with conventional (RelyX ARC) or with self-adhesive resin cement (RelyX U200). The lowest bond strength values were obtained when calcium silicate-based sealers were associated with conventional resin cement (Bio C Sealer/RelyX ARC and Sealer Plus BC/RelyX ARC). Except for Sealer Plus BC/RelyX ARC, all groups presented lower bond strength at the apical portion compared to the cervical portion of the post. Adhesive failures between cement and post and cement and dentin were predominant (55.3%). Calcium silicate-based sealers decreased the bond strength of fiber posts cemented with conventional resin cement.


Resumo Este estudo teve como objetivo avaliar a influência de cimentos à base de silicato de cálcio na resistência de união de pinos de fibra utilizando cimentos resinosos convencionais e autoadesivos. Sessenta dentes humanos monorradiculares foram selecionados. Os canais foram preparados um instrumento reciprocante 40.06. As raízes foram distribuídas aleatoriamente em seis grupos (n = 10) de acordo com as estratégias de obturação do canal e cimentação dos pinos de fibra: AH Plus/RelyX ARC; AH Plus/RelyX U200; Bio C Sealer/RelyX ARC; Bio C Sealer/RealyX U200; Sealer Plus BC/RelyX ARC; e Sealer Plus BC/RelyX U200. As raízes foram seccionadas transversalmente e foi obtido um espécime por terço. O teste de push-out foi realizado em uma velocidade de 1mm/min. Os padrões de falha foram descritos após avaliação em estereomicroscópio com aumento de 10×. A resistência de união foi calculada e analisada por ANOVA e teste de Tukey. AH Plus não influenciou na resistência de união dos pinos de fibra cimentados com cimento resinoso convencional (RelyX ARC) ou autoadesivo (RelyX U200) (p > 0,05). Os menores valores de resistência de união foram obtidos quando os cimentos à base de silicato de cálcio foram associados ao cimento resinoso convencional (Bio C Sealer/RelyX ARC e Sealer Plus BC/RelyX ARC) (p < 0,05). Com exceção do Sealer Plus BC/RelyX ARC, todos os grupos apresentaram menor resistência de união na porção apical em comparação com a porção cervical do pino (p < 0,05). Falhas adesivas entre cimento e pino e cimento e dentina foram predominantes (55,3%). Cimentos a base de silicato de cálcio diminuíram a resistência de união de pinos de fibra cimentados com cimento resinoso convencional.

3.
RFO UPF ; 26(2): 206-212, 20210808. ilus, tab
Artículo en Portugués | LILACS, BBO | ID: biblio-1443776

RESUMEN

Objetivos: avaliar a sujidade de limas rotatórias e reciprocantes após instrumentação e procedimentos de limpeza pré-esterilização. Materiais e métodos: 24 limas rotatórias e as 24 limas reciprocantes foram divididas, aleatoriamente, em dois grandes grupos. No primeiro grupo, as 12 limas rotatórias e as 12 limas reciprocantes foram divididas, aleatoriamente, em seis subgrupos (SG): SG1 (controle negativo 1/n=1) ­ 1 lima rotatória não submetida à instrumentação; SG2 (controle negativo 2/n=1) ­ 1 lima reciprocante não submetida à instrumentação; SG3 (controle positivo 1/n=1) ­ 1 lima rotatória submetida à instrumentação e não submetida a qualquer protocolo de limpeza; SG4 (controle positivo 2/n=1) ­ 1 lima reciprocante submetida à instrumentação e não submetida a qualquer protocolo de limpeza; SG5 (grupo teste/n=10) ­ 10 limas rotatórias submetidas à instrumentação e submetidas ao protocolo de lavagem manual; SG6 (grupo teste/ n=10) ­ 10 limas reciprocantes submetidas à instrumentação e submetidas ao protocolo de lavagem manual. No segundo grupo, as 12 limas rotatórias e as 12 limas reciprocantes foram divididas, aleatoriamente, nos mesmos subgrupos, substituindo, nos subgrupos 5 e 6, a lavagem manual pela lavagem em cuba ultrassônica. A análise do nível de sujidade foi realizada por microscopia eletrônica de varredura (MEV), sendo os dados submetidos ao teste de Kruskal-Wallis, com nível de significância de 5%. Resultados: a menor média de sujidade entre os grupos experimentais foi encontrada no SG5 do G1, sem diferença significante em relação aos demais grupos testados (p>0,05). Conclusão: conclui-se que os protocolos de limpeza testados não foram completamente efetivos para a remoção de sujidade das limas endodônticas.(AU)


Objective: to evaluate the dirt of rotary and reciprocating files after instrumentation and pre- -sterilization cleaning procedures. Materials and Methods: 24 rotary files and the 24 reciprocating files were randomly divided into two groups. In the 1st group, 12 rotary files and 12 reciprocating files were randomly divided into six subgroups (SG): SG1 (negative control 1/n=1) ­ 1 rotary file not subjected to instrumentation; SG2 (negative control 2/n=1) ­ 1 reciprocating file not subjected to instrumentation; SG3 (positive control 1/n=1) ­ 1 rotary file submitted to instrumentation and not submitted to any cleaning protocol; SG4 (positive control 2/n=1) ­ 1 reciprocating file submitted to instrumentation and not submitted to any cleaning protocol; SG5 (test group/n=10) ­ 10 rotary files submitted to instrumentation and submitted to the manual cleaning protocol; SG6 (test group/n=10) ­ 10 reciprocating files submitted to instrumentation and submitted to the manual cleaning protocol. In the 2nd group, the 12 rotary files and the 12 reciprocating files were randomly divided into the same subgroups, substituting, in subgroups 5 and 6, manual with ultrasonic bath cleaning. The analysis of dirt levels was performed by scanning electron microscopy (SEM), being the data submitted to the Kruskal-Wallis test, with a significance level of 5%. Results: the lowest average of dirt between the experimental groups was found in SG5 of G1, with no significant difference when compared to the other groups (p>0.05). Conclusion: it could be concluded that the cleaning protocols were not completely effective in removing dirt from endodontic files.(AU)


Asunto(s)
Humanos , Esterilización/métodos , Preparación del Conducto Radicular/instrumentación , Instrumentos Dentales , Valores de Referencia , Microscopía Electrónica de Rastreo , Distribución Aleatoria , Contaminación de Equipos , Estadísticas no Paramétricas , Preparación del Conducto Radicular/métodos
4.
Biosci. j. (Online) ; 37: e37004, Jan.-Dec. 2021. ilus, tab
Artículo en Inglés | LILACS | ID: biblio-1359866

RESUMEN

The aim of this study was to evaluate apical transportation and apical root canal sealing after root canal filling in human teeth prepared with MTwo® Rotary System with and without apical foramen enlargement. Twenty mandibular premolars were divided into two groups (n=10). Group 1 had root canals prepared 1mm beyond the apical foramen. Group 2 had root canals prepared 1mm below the root canal length. After chemo-mechanical preparation, samples were submitted to scanning electronic microscopy. Apical foramen images had 75x magnification at standardized positions, allowing measurements from the apical foramen area before and after root canal preparation, and after root canal filling. Apical foramen shape and apical transportation, as well as its level of circumferential filling after root canal preparation were accessed using the Image Subtraction System. Scanning electronic microscopy analysis demonstrated that samples of Group 1 showed larger foraminal diameter than samples of Group 2 (p<0.05). Apical foramen transportation was statistically different between Groups 1 and 2 (p=0.0108). Furthermore, the apical foramen sealing also differed statistically between groups 1 and 2 (p=0.0007) and 100% of samples of Group 1 showed apical root canal sealing. Apical root canal sealing was more effective when the root canal was prepared with apical foramen enlargement, even when the apical transportation was detected.


Asunto(s)
Obturación del Conducto Radicular/instrumentación , Ápice del Diente
5.
RFO UPF ; 25(1): 42-49, 20200430. ilus, tab
Artículo en Inglés | LILACS, BBO | ID: biblio-1357721

RESUMEN

Purpose: evaluate the antimicrobial activity of intracanal dressings and their influence on dentinal colour changes. Material and methods: eighty single-rooted human extracted teeth were decoronated and divided into eight groups (n=10) according to intracanal dressing protocols inserted into the root canals: G1­distilled water (DW); G2­2% chlorhexidine gel (CHX); G3­calcium hydroxide (Ca[OH]2)+DW; G4­grape seed extract (GSE)+DW; G5­ginger extract (GE)+DW; G6­Ca(OH)2+CHX; G7­GSE+CHX; and G8­GE+CHX. The antimicrobial activity was evaluated by colony-forming units (CFUs) counting and dentinal colour changes was evaluated by digital spectrophotometry. Data were statistically analysed by One-way ANOVA followed by Tukey´s post hoc test (antimicrobial evaluation) and non-parametric Wilcoxon followed by the Mann- Whitney-U test (colour change evaluation) (α=0.05). Results: the highest bacterial reduction was observed in groups 4, 6, 7 and 8, with no significant difference between them (p<0.05). Groups 4 and 7 showed the highest medians of dentinal colour change (p<0.05). Conclusion: the addition of CHX improved the antimicrobial activity of GE-based intracanal dressing, with no effect in GSE-based intracanal dressing; moreover, these protocols induced significant dentinal colour changes. (AU)


Objetivo: avaliar a atividade antimicrobiana de medicações intracanais e sua influência na alteração da cor dentinária. Materiais e métodos: oitenta dentes humanos extraídos unirradiculares foram seccionados e divididos em oito grupos (n = 10), de acordo com os protocolos de medicação intracanal inseridos nos canais radiculares: água destilada G1 (DW); G2-2% de gel de clorexidina (CHX); hidróxido de cálcio G3 ­ (Ca [OH] 2) + DW; extrato de semente de uva G4 (GSE) + DW; extrato de gengibre G5 (GE) + DW; G6- Ca (OH) 2 + CHX; G7 ­ GSE + CHX; e G8-GE + CHX. A atividade antimicrobiana foi avaliada por contagem de unidades formadoras de colônias (UFCs) e as alterações de cor dentinária foram avaliadas por espectrofotometria digital. Os dados foram analisados estatisticamente por ANOVA one-way, seguida pelo teste post hoc de Tukey (avaliação antimicrobiana) e Wilcoxon não paramétrico, seguido pelo teste de Mann- Whitney-U (avaliação da mudança de cor) (α = 0,05). Resultados: a maior redução bacteriana foi observada nos grupos 4, 6, 7 e 8, sem diferença significativa entre eles (p < 0,05). Os grupos 4 e 7 apresentaram as maiores medianas da alteração da cor dentinária (p < 0,05). Conclusão: a adição de CHX melhorou a atividade antimicrobiana da medicação intracanal baseado em GE, sem efeito na medicação intracanal baseado em GSE; além disso, esses protocolos induziram alterações significativas na cor dentinária.(AU)


Asunto(s)
Humanos , Irrigantes del Conducto Radicular/farmacología , Irrigantes del Conducto Radicular/química , Extractos Vegetales/química , Clorhexidina/farmacología , Clorhexidina/química , Enterococcus faecalis/efectos de los fármacos , Dentina/efectos de los fármacos , Espectrofotometría/métodos , Hidróxido de Calcio/química , Recuento de Colonia Microbiana , Análisis de Varianza , Color , Estadísticas no Paramétricas , Zingiber officinale/química , Dentina/química , Extracto de Semillas de Uva/química
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA