Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
1.
Indian Heart J ; 2018 Jan; 70(1): 185-190
Artículo | IMSEAR | ID: sea-191762

RESUMEN

Our previous research found seven specific factors that cause system delays in ST-elevation Myocardial infarction management in developing countries. These delays, in conjunction with a lack of organized STEMI systems of care, result in inefficient processes to treat AMI in developing countries. In our present opinion paper, we have specifically explored the three most pertinent causes that afflict the seven specific factors responsible for system delays. In doing so, we incorporated a unique strategy of global STEMI expertise. With this methodology, the recommendations were provided by expert Indian cardiologist and final guidelines were drafted after comprehensive discussions by the entire group of submitting authors. We expect these recommendations to be utilitarian in improving STEMI care in developing countries.

3.
Rev. bras. cardiol. invasiva ; 23(1): 22-27, abr.-jun.2015. tab
Artículo en Portugués | LILACS, SES-SP, SESSP-IDPCPROD, SES-SP | ID: lil-782171

RESUMEN

O stent liberador de everolimus XIENCE V® é um stent farmacológico de nova geração que incorpora uma plataforma de cromo-cobalto de baixo perfil (81 m) e um polímero de elevada biocompatibilidade (fluoropolímero), o qual carreia e controla a liberação do fármaco everolimus. Estudos recentes demonstram segurança e eficácia sustentadas do dispositivo XIENCE V® no tratamento de populações da prática clínica. Nosso objetivo foi reportar resultados clínicos de 12 meses do protocolo brasileiro BRAVO. Métodos: O registro BRAVO foi um estudo prospectivo, não randomizado, de braço único, multicêntrico (25centros), que avaliou os resultados clínicos tardios de 535 pacientes minimamente selecionados, tratados com o stent farmacológico XIENCE V®.Resultados: Cerca de 40% dos pacientes tinham diabetes, 25% infarto agudo do miocárdio prévio e 42% apresentaram-se com síndrome coronária aguda. A maioria das lesões (69%) era de elevada complexidade(ACC/AHA tipo B2/C). As médias da extensão e do diâmetro nominais dos stents foram, respectivamente, 19,9 ± 5,3 mm e 3,0 ± 0,4 mm. Os sucessos angiográfico e de procedimento foram de 99,7 e 98%, respectivamente. Aos 12 meses, a taxa cumulativa de eventos cardíacos adversos maiores, disponível em 100% dos pacientes, foi de 5,6% (morte cardíaca: 1,3%; infarto agudo do miocárdio: 3,0%; revascularização da lesão-alvo: 2,2%). Já a trombose de stent ocorreu em cinco pacientes (0,9%), sendo reportada apenas uma ocorrência entre 6 e 12 meses. Conclusões: O stent farmacológico XIENCE V® demonstrou segurança e eficácia sustentadas ao final de 12meses no tratamento de lesões coronárias complexas em pacientes da prática diária...


The Xience VTM everolimus-eluting stents is a new generation drug-eluting stent (DES)that incorporates a low profile cobalt-chromium platform (81 m) and a highly biocompatible polymer(fluoropolymer), which carries and controls the release of everolimus. Recent studies have demonstrated sustained safety and efficacy of the Xience VTM in the treatment of real-world populations. Our aim was to report the clinical results of 12 months of the BRAVO Brazilian protocol. Methods: The BRAVO Registry was a prospective, non-randomized, single-arm, multicenter (25 centers) study that evaluated the late clinical results of 535 minimally selected patients treated with the drug eluting stent Xience VTM in Brazilian daily practice. Results: Overall, 40% of patients had diabetes, 25% prior myocardial infarction, and 42% presented with acute coronary artery syndrome. The majority of lesions (69%) was highly complex (ACC/AHA type B2 or C).The mean length and the nominal stent diameter were 19.9 ± 5.3 mm and 3.0 ± 0.4 mm, respectively.The angiographic and procedural successes were 99.7 and 98%, respectively. At 12 months, the cumulative rate of major adverse cardiac events, available in 100% of patients, was 5.6% (cardiac death: 1.3%; acute myocardial infarction: 3.0%; revascularization of the target lesion: 2.2%). Stent thrombosis occurred in 5 patients (0,9%), and only 1 case was reported between 6 and 12 months. Conclusions: The drug-eluting stent Xience V™ demonstrated sustained safety and efficacy up to 12 months in the treatment of complex coronary lesions in patients from daily practice...


Asunto(s)
Humanos , Masculino , Femenino , Persona de Mediana Edad , Enfermedad Coronaria , Intervención Coronaria Percutánea/métodos , Pacientes , Stents Liberadores de Fármacos , Trombosis/complicaciones , Trombosis/diagnóstico , Interpretación Estadística de Datos , Estudios Prospectivos , Factores de Riesgo , Prótesis e Implantes/métodos , Resultado del Tratamiento
4.
Rev. bras. cardiol. invasiva ; 22(1): 81-86, Jan-Mar/2014.
Artículo en Portugués | LILACS | ID: lil-712737

RESUMEN

Introdução: A intervenção coronária percutânea primária é hoje o método preferencial de reperfusão na abordagem de pacientes com infarto agudo do miocárdio com supradesnivelamento do segmento ST. Em boa parte desses casos, ocorre o fenômeno de não reperfusão, que é a incapacidade de se reperfundir uma região do miocárdio após o restabelecimento da patência de uma artéria coronária epicárdica previamente ocluída. O benefício de inibidores da glicoproteína IIb/IIIa, bloqueando a via final comum da agregação plaquetária, tem sido sugerido em estudos de síndromes coronárias agudas, mas persistem pontos obscuros quanto à sua real eficácia, no contexto da não reperfusão, em pacientes tratados com intervenção coronária percutânea primária. Métodos: Investigação multicêntrica que avaliou o impacto da administração precoce do inibidor da glicoproteína IIb/IIIa de baixo peso molecular tirofiban, em forma duplo-mascarada, controlada por placebo, sobre a ocorrência de não reperfusão, empregando métodos angiográficos e eletrocardiográfico para documentar (1) os fluxos coronário epicárdico, pelo escore TIMI, e microcirculatório, pelo escore MBG de opacificação e escoamento miocárdicos; (2) a resolução do supradesnivelamento do segmento ST, como índice final do sucesso da reperfusão. Conclusões: Se comprovada redução da incidência de não reperfusão tanto 90 minutos como 24 horas após a intervenção coronária percutânea primária, este estudo-piloto, deve nortear a implementação de estudo mais abrangente, para investigar o possível impacto do bloqueio sistemático ...


Background: Primary percutaneous coronary intervention is currently the preferred method to treat patients with ST-segment elevation acute myocardial infarction. The no-reflow phenomenon, which is the inability to reperfuse a region of the myocardium after restoration of patency of a previously occluded epicardial coronary artery, is observed in a considerable proportion of these patients. The benefit of IIb/IIIa glycoprotein inhibitors, blocking the final common pathway of platelet aggregation, has been suggested in studies of acute coronary syndromes, but their actual efficacy in the context of no-reflow in patients treated with primary percutaneous coronary intervention remains unclear. Methods: The aim of this multicenter, double-blinded, placebo controlled study is to assess the impact of the early administration of the low molecular weight glycoprotein IIb/ IIIa inhibitor tirofiban on the incidence of no-reflow using angiographic and electrocardiographic methods to determine: (1) the epicardial coronary flow, using the TIMI score, and the microcirculatory flow, using the MBG score of opacification and myocardial flow; (2) the resolution of the ST segment elevation, as the final index of the success of reperfusion. Conclusions: If the decrease in no-reflow incidence at 90 minutes and 24 hours after primary percutaneous coronary intervention is confirmed, this pilot study should guide the implementation of a larger study to investigate the possible impact of the systematic inhibition of the final common pathway of platelet aggregation on the mortality of ST-segment elevation acute myocardial infarction patients. .


Asunto(s)
Humanos , Infarto del Miocardio/complicaciones , Infarto del Miocardio/fisiopatología , Intervención Coronaria Percutánea/métodos , Agregación Plaquetaria , Reperfusión Miocárdica/métodos , Inhibidores de Agregación Plaquetaria/administración & dosificación , Resultado del Tratamiento , Terapia Trombolítica/métodos
5.
Arq. bras. cardiol ; 101(5): 379-387, nov. 2013. ilus, tab
Artículo en Portugués | LILACS | ID: lil-696881

RESUMEN

FUNDAMENTO: Na angioplastia coronária percutânea (ACP), os vasos de fino calibre representam um fator de risco para reestenose. O stent farmacológico (SF) autoexpansível Sparrow®, de perfil menor que os sistemas atuais, nunca foi testado nesse cenário. OBJETIVOS: Avaliar a eficácia tardia do SF Sparrow®, com relação à perda luminal tardia intrastent (PLT intrastent) aos oito meses. MÉTODOS: Estudo prospectivo, randomizado, em P com doença arterial coronária (DAC) sintomática ou com isquemia documentada, submetido à ACP em vasos de calibre < 2,75 mm, dividido em dois grupos quanto ao tipo de stent Sparrow®: grupo 1, SF; grupo 2, stent não farmacológico (SNF). O seguimento clínico foi de 12 meses. De imediato e aos oito meses, avaliação pela angiografia coronária quantitativa (ACQ). Para o cálculo da amostra estimou-se diminuição de mais de 65% de PLT intrastent com o SF. Para análise estatística utilizou-se o programa IBM SPSS Statistics® versão 19 (Chicago, Illinois, EUA). RESULTADOS: Foram incluídos 24 p, 12 em cada grupo. Os grupos SF e SNF foram semelhantes quanto à idade (63,25 ± 10,01 versus 64,58 ± 11,54, p = 0,765), sexo masculino (58,3% versus 33,3%, p = 0,412), fatores de risco e todos os aspectos angiográficos. Os resultados imediatos foram satisfatórios em ambos os grupos. Aos oito meses, a PLT intrastent foi significativamente menor no SF do que no SNF (SF 0,25 ± 0,16 versus SNF 0,97 ± 0,76, p = 0,008). CONCLUSÃO: Em ACP de vasos de calibre < 2,75 mm, o SF Sparrow® determinou significativa redução da PLT intrastent, em comparação ao SNF Sparrow®.


BACKGROUND: Small vessels represent a risk factor for restenosis in percutaneous coronary angioplasty (PCA). The Sparrow® self-expanding drug-eluting stent, which has a lower profile than the current systems, has never been tested in this scenario. OBJECTIVES: To evaluate the late effectiveness of the Sparrow® drug-eluting stent, regarding in-stent late lumen loss (LLL). METHODS: Patients with ischemia, symptomatic or documented, were submitted to PCA in vessels with reference diameter < 2.75 mm, divided into two groups regarding Sparrow® stent type: group 1: Sparrow® drug-eluting stent (DES), group 2: Sparrow® bare metal stent (BMS). Clinical follow-up duration was 12 months. Evaluation using quantitative coronary angiography (QCA) was performed immediately and at 8 months. A decrease of over 65% of in-stent LLL with DES was estimated to calculate sample size. IBM® SPSS software, release 19 (Chicago, Illinois, USA) was used for the statistical analysis. RESULTS: A total of 24 patients were randomized, 12 in each group. The DES and BMS groups were similar in age (63.25 ± 10.01 vs. 64.58 ± 11.54, p = 0.765), male gender (58.3% vs. 33.3%, p = 0.412), risk factors and all angiographs aspects. Immediate results were satisfactory in both groups. At 8 months in-stent late lumen loss was significantly lower in DES than in BMS group (DES vs. BMS 0.25 ± 0.16 0.97 ± 0.76, p = 0.008). CONCLUSION: In small-vessel PCA, the Sparrow® DES determined significant reduction in in-stent LLL, when compared to Sparrow® BMS.


Asunto(s)
Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Reestenosis Coronaria/prevención & control , Vasos Coronarios/fisiopatología , Stents Liberadores de Fármacos , Miniaturización , Angioplastia Coronaria con Balón , Estenosis Coronaria , Stents , Sirolimus/administración & dosificación , Resultado del Tratamiento
7.
São Paulo; s.n; 2008. 95 p. ilus, tab, graf.
Tesis en Portugués | LILACS | ID: lil-587257

RESUMEN

O presente estudo procurou avaliar, prospectivamente, a segurança do sistema de tele-eletrocardiografia para a liberação de pacientes que se apresentem a postos de saúde com queixa de dor torácica. Avaliamos a incidência de infarto do miocárdio dessa população ao longo de seis meses. Como objetivo secundário, correlacionamos, retrospectivamente, a razão das probabilidades entre diferentes indicadores clínicos e eletrocardiográficos e a ocorrência do infarto do miocárdio. Entre junho e dezembro de 2006, 32444 pacientes foram atendidos em postos de saúde pública, carentes de cardiologistas e tiveram o seu tele-eletrocardiograma transmitido até uma central de telemedicina, através de linha telefônica fixa. Selecionaram-se 1535 pacientes atendidos devido a dor torácica, que tinham mais de 50 anos e apresentavam exame clínico, laboratorial (troponina I ou creatino fosfoquinase fração MB-CKMB) e tele-eletrocardiográfico normais além de consentirem em repetir o tele-eletrocardiograma após um e seis meses. Todos os pacientes foram seguidos durante seis meses. Não houve eventos durante o primeiro mês. No segundo mês houve 12 (0,8%) infartos; no terceiro mês, 18 (1,2%); no quarto mês, 38 (2,4%) e no sexto, 18 (1,2%). Ao longo dos seis meses houve 15(1%) óbitos, sendo 9(0,6%) de origem cardíaca; 9 (0,6%) acidentes vasculares encefálicos e 86 (5,6%) infartos agudos do miocárdio. Entre as variáveis que se correlacionaram, independentemente, com maior chance de infarto agudo do miocárdio, encontrou-se a obesidade grau I [p=0,009 RC 4,5 IC 95%(1,5-13,8)], a dislipidemia [p< 0,0001 RC 3,4 IC 95%(2,0-5,8)], a baixa amplitude da onda T em V2 [p<0,001 RC 2,9 IC 95%(2,4-3,5)] e o sobrepeso [p=0,019 RC 2,6 IC 95%(1,2-5,7)]...


The present study aimed at prospectively evaluating the reliability of teleeletrocardiography for the discharge of chest pain patients who present themselves at remote medical centers. The incidence of acute myocardial infarction among this population was evaluated during a period of six months. As a secondary objective, the correlation between different clinical and electrocardiographic features and the occurrence of myocardial infarction was retrospectively checked. Between June and December of 2006, 32.444 patients were treated in public medical centers which lacked the assistance of cardiologists. Those patients had their electrocardiogram transmitted to a telemedicine center over a fixed-wired telephone line. Among them 1535 patients who had been assisted due to chest pain were selected. Those patients were all older than 50 years and showed normal clinical and laboratorial (troponine I or creatine phosphokinase MB-CKMB fraction) exams, as well as normal tele-electrocardiograms. They also agreed to repeat the teleelectrocardiogram in a six-month period. All patients were followed up to the sixth-month. In the second month, there were 12 (0,8%) infarctions; in the third month there were 18 (1,2%) infarctions; in the fourth month there were 38 (2,4%) infarctions, and in the sixth month there were 18 (1,2%) infarctions. Over that six month period, there were 15 (1%) deaths, 9 (0,6%) of which were related to cardiac causes; 9 (0,6%) strokes, and 86 (5,6%) acute myocardial infarctions. Among the variables which independently correlated with greater risk of acute myocardial infarction, we found grade I obesity [p=0,009 RC 4,5 IC95%(1,5-13,8)]; dyslipidemia [p<0,0001 RC 3,4 IC 95%(2,0-5,8)]; low T-wave amplitude in V2 [p<0,001 RC 2,9 IC 95%(2,4-3,5)], and overweight [p=0,019 RC 2,6 IC 95%(1,2-5,7)]...


Asunto(s)
Humanos , Electrocardiografía , Infarto del Miocardio , Telemedicina
9.
Arq. bras. cardiol ; 65(4): 313-315, Out. 1995.
Artículo en Portugués | LILACS | ID: lil-319320

RESUMEN

PURPOSE: To evaluate the vasodilation effect of intracoronary isosorbide mononitrate (ISMN) on the coronary arteries, systolic aortic pressure (SAP) and cardiac rhythms. METHODS: Forty patients aged 61 (40-72) years, 30 (75) male, were randomized to receive on a double blind fashion, 20 mg of ISMN or placebo. The two groups had similar baseline characteristics. Quantitative coronary arteriography [by cardiovascular measurement system (CMS)] and SAP were compared before and after ISMN. We also observed the cardiac rhythm. RESULTS: There were no arrhythmias. Reference vessel diameter increased from 2.6 +/- 0.5 mm before to 2.9 +/- 0.4 mm after ISMN and did not change, mean 2.9 +/- 0.5 mm, before and after placebo. There was a difference between ISMN and placebo (p < 0.0001). There was no difference in the SAP change between the two groups, 4.2 +/- 0.7 mmHg with ISMN and 1.8 +/- 0.5 mmHg with placebo (p = NS). CONCLUSION: ISMN promotes a safe and effective vasodilation of the coronary arteries with no major effects in cardiac rhythm and systolic aortic pressure.


Objetivo - Avaliar o efeito do mononitrato-5 de isossorbida (MNIS) sobre as artérias coronárias, pressão arterial sistêmica média (PAS) e ritmo cardíaco, quando injetado intracoronário. Métodos - Quarenta pacientes, idade entre 40 a 72 (média 61) anos, 30 (75%) homens, foram sorteados para receber, de maneira cega, 20mg de MNIS ou placebo (PL). Os dois grupos tinham características basais semelhantes. A angiografia coronária quantitativa (através do sistema CMS - cardiovascular measurement system) a PAS e o ritmo cardíaco foram comparados antes e após a injeção de MNIS/PL. Resultados -Não houve arritmias. O diâmetro coronário variou de 2,6± 0,5mm, antes, para 2,9±0,4mm, após oMNIS, e nuo variou com a injeção de PL, permanecendo 2,9±0,5mm antes e após, havendo diferença significativa entre o MNIS e o PL (p<0,0001). A variação da PAS não foi diferente entre os 2 grupos, sendo 4,2±0,7mmHg no grupo MNIS e 1,85±0,5mmHg no grupo PL (p=NS). Conclusão - O MNIS promove eficaz e segura dilatação coronária, pois não induz à hipotensão arterial sistêmica ou alteração no ritmo cardíaco


Asunto(s)
Humanos , Masculino , Femenino , Adulto , Persona de Mediana Edad , Vasodilatadores , Vasos Coronarios , Dinitrato de Isosorbide , Presión Arterial/efectos de los fármacos , Dinitrato de Isosorbide , Angiografía Coronaria , Inyecciones Intraarteriales , Método Doble Ciego
10.
Arq. bras. endocrinol. metab ; 37(1): 34-6, mar. 1993. ilus
Artículo en Portugués | LILACS | ID: lil-162704

RESUMEN

Os autores apresentam um caso de diabetes pancreático fibrocalculoso que evoluiu por 12 anos sem cetose, mas com complicaçoes crônicas oculares, neurológicas e insuficiência pancreática exócrina. A histologia do pâncreas evidenciou calcificaçoes, fibrose e despopulaçao de ilhotas de Langerhans. Chamam a atençao para os múltiplos fatores que poderiam estar implicados na etiologia desta forma de diabetes, como o consumo de alimentos de baixo valor proteico (mandioca), a desnutriçao crônica, parasitoses intestinais, associados a uma predisposiçao familiar ao diabetes. Trata-se de uma forma incomum de diabetes na América do Sul.


Asunto(s)
Humanos , Masculino , Adulto , Calcinosis/patología , Diabetes Mellitus/complicaciones , Páncreas/patología , Desnutrición Proteico-Calórica , Diabetes Mellitus/clasificación , Diabetes Mellitus/genética , Enfermedades Parasitarias/complicaciones , Trastornos Nutricionales , Retinopatía Diabética/complicaciones , Factores Socioeconómicos
11.
Arq. bras. cardiol ; 50(5): 335-337, maio 1988. ilus
Artículo en Portugués | LILACS | ID: lil-59398

RESUMEN

Os autores apresentam um caso de cor triatriatum dexter, diagnosticado por ecodoplercardiografia bidimensional, associado a comuniçäo interatrial e estenose pulmonar valvar. A anomalia näo foi detectada no estudo hemodinâmico. O ecodopplercardiograma mostrou uma ampla membrana dividindo o átrio em duas cavidades, estendendo-se de sua porçäo inferior, imediatamente acima do anel tricúspide, até os orifícios da veias cavas. Esses achados foram confirmados pela necrópsia


Asunto(s)
Humanos , Masculino , Adulto , Corazón Triatrial/diagnóstico , Estenosis de la Válvula Pulmonar/complicaciones , Corazón Triatrial/complicaciones , Ecocardiografía , Defectos del Tabique Interatrial/complicaciones
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA