Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 107
Filtrar
1.
Braz. j. oral sci ; 23: e243355, 2024. ilus
Artículo en Inglés | LILACS, BBO | ID: biblio-1551649

RESUMEN

Aim: This study aimed to perform an in vitro comparative analysis of the antifungal activity of different calcium silicate-based endodontic sealers against three fungal species. Methods: The antifungal properties of three calcium silicate-based sealers were tested: Bio-C Sealer, Cambiar a Sealer Plus BC, and MTA-Fillapex. Two commonly used sealers were used as controls: AH Plus and Endomethasone. An agar diffusion test was performed to analyze the antifungal activity of the sealers against Candida albicans, Candida glabrata, Candida tropicalis, and a mixed microbial culture medium. The results were analyzed using ANOVA (p <0.05). Results: Endomethasone exhibited the highest inhibition against all strains examined, maintaining a consistent level of inhibition throughout 7 days. MTA-Fillapex demonstrated the best performance among the calcium silicate-based sealers for the three fungal species (p < 0.05), maintaining stable values over the 7 days, surpassing that of Endomethasone. Nevertheless, MTA-Fillapex only exhibited antimicrobial effect against the mixed culture for the first 24 hours, and no antimicrobial activity was observed at 48 hours, being surpassed by all tested sealers (p < 0.05). Conclusion: Of all silicate-based sealers tested, only MTA-Fillapex exhibited promising antifungal activity. Nevertheless, care must be taken when extrapolating these results, as MTA-Fillapex exhibited poor antimicrobial activity when tested in mixed microbial cultures


Asunto(s)
Materiales de Obturación del Conducto Radicular , Cemento de Silicato , Bacterias , Candida albicans , Candida glabrata , Candida tropicalis , Endodoncia , Antifúngicos/análisis
2.
Braz. dent. j ; 34(3): 33-41, May-June 2023. tab, graf
Artículo en Inglés | LILACS-Express | LILACS, BBO | ID: biblio-1447599

RESUMEN

Abstract This in vitro study compared the antimicrobial efficacy of 2.5% sodium hypochlorite (NaOCl) and 8 µg/mL ozonated water agitated by passive ultrasonic irrigation (PUI) or PUI combined with EndoActivator (EA) against mature multispecies biofilm. One hundred and five oval-shaped mandibular premolars were instrumented, sterilized, and inoculated with Enterococcus faecalis, Candida albicans, and Staphylococcus aureus, divided into: control group - saline; O3 group - ozonated water; O3 PUI group - ozonated water with PUI agitation; O3 PUI+EA group - ozonated water with PUI+EA agitation; NaOCl group - NaOCl; NaOCl PUI group - NaOCl with PUI agitation; and NaOCl PUI+EA group - NaOCl with PUI+EA agitation. Microbiological samples were collected before (S1) and after (S2) the disinfection procedures and the data were statistically analyzed using the Kruskal-Wallis test. In the culture method, there was significant disinfection in the O3 PUI+EA, NaOCl, NaOCl PUI, and NaOCl PUI+EA groups (p˂0.05). The combination of NaOCl with PUI+EA reduced microbial counts to zero (p˂0.05). In the qPCR method, there was a significant reduction in the total count of viable microorganisms in the O3 PUI, O3 PUI+EA, NaOCl, NaOCl PUI, and NaOCl PUI+EA groups (p˂0.05). It can be concluded that 2.5% NaOCl with and without agitation, as well as 8 µg/mL ozonated water with its action enhanced by the agitation techniques, were effective in root canal disinfection, and their antimicrobial efficacy is related to the microorganisms present in the biofilm.


Resumo Este estudo in vitro comparou a desinfecção do hipoclorito de sódio 2,5% (NaOCl) e da água ozonizada 8 µg/mL agitados pela irrigação ultrassônica passiva (PUI) e por associação da PUI com EndoActivator (EA) na redução de biofilme misto maduro. Cento e cinco pré-molares inferiores ovalados foram instrumentados, esterilizados e inoculados com Enterococcus faecalis, Candida albicans e Staphylococcus aureus, divididos em: Grupo controle: soro; Grupo O3: água ozonizada; Grupo O3 PUI: água ozonizada agitada por PUI; Grupo O3 PUI + EA: água ozonizada agitada por PUI e EA: Grupo NaOCl: hipoclorito de sódio; Grupo NaOCl PUI: hipoclorito de sódio agitado por PUI; Grupo NaOCl PUI + EA: hipoclorito de sódio agitado por PUI e EA. Amostras microbiológicas foram coletadas antes (S1) e após (S2) os procedimentos de desinfecção e os dados foram analisados estatisticamente pelo teste de Kruskal-Wallis. No método de cultura, houve desinfecção significativa nos grupos O3 PUI + EA, NaOCl, NaOCl PUI e NaOCl PUI + EA (p˂0.05), sendo que no grupo NaOCl PUI + EA não houve crescimento de microrganismo (p˂0.05). No método de qPCR, nas contagens dos microrganismos antes e após os protocolos de desinfecção, houve redução microbiana nos grupos O3 PUI, O3 PUI + EA, NaOCl, NaOCl PUI, NaOCl PUI + EA (p˂0.05). Concluiu-se que o NaOCl 2,5% com e sem agitação foi eficiente, assim como a água ozonizada 8 µg/mL potencializada pelos métodos de agitação na desinfecção e que a mesma está relacionada com os microrganismos presentes no biofilme.

3.
Rev. odontol. UNESP (Online) ; 51: e20220046, 2022. tab, ilus
Artículo en Portugués | LILACS, BBO | ID: biblio-1424236

RESUMEN

Introdução: É importante saber se o hipoclorito de sódio (NaOCl) influencia a resistência à fadiga cíclica das limas de níquel-titânio (NiTi). Objetivo: Avaliar a influência de NaOCl 2,5% na resistência à fadiga cíclica de dois sistemas de NiTi. Material e método: 40 instrumentos rotatórios - 20 TruNatomy® (TRU, Dentsply Sirona, Maillefer, Ballaigues, Suíça) e 20 Prodesing Logic2® (PDL2, Bassi, Belo Horizonte, Minas Gerais, Brasil) - foram aleatoriamente distribuídos em 4 grupos experimentais (n = 10) imersos em água destilada (H2O) e NaOCl 2,5% em temperatura a 37°C. Foram submetidos a testes de fadiga cíclica mensurando o número de ciclos para fratura (NCF) e análise dessas superfícies pós-teste em microscópio eletrônico por varredura. Para a análise estatística entre os grupos, foi aplicada a análise de variância (ANOVA), complementada com o pós-teste de Tukey. Resultado: Houve diferença estatística em todos os grupos (P<0.05). Os instrumentos PDL2 obtiveram maior resistência à fratura nas condições em H2O e em NaOCl 2,5% comparados aos instrumentos TRU. Na análise de grupos de instrumentos nas soluções de NaOCl e H2O, foi observado que o NaOCl 2,5% diminuiu o NCF. Conclusão: A resistência à fadiga cíclica dos instrumentos TRU e PDL2 diminuiu com NaOCl 2,5%. Os instrumentos PDL2 foram mais resistentes à fratura em relação aos instrumentos TRU.


Introduction: It is important to know whether sodium hypochlorite (NaOCl) influences the cyclic fatigue resistance of nickel-titanium (NiTi) files. Objective: To evaluate the influence of NaOCl 2.5% on the cyclic fatigue resistance of two NiTi systems. Material and method: Forty rotary instruments - 20 TruNatomy® (TRU, Dentsply Sirona, Maillefer, Ballaigues, Switzerland) and 20 Prodesign Logic2® (PDL2, Bassi, Belo Horizonte, Minas Gerais, Brazil) - were distributed randomly across four experimental groups (n=10) and submerged in distilled water (H2O) or 2.5% NaOCl at 37°C according to allocation. Cyclic fatigue testing was then performed, measuring the number of cycles to fracture (NCF), and post-test surfaces were analysed by scanning electron microscopy (SEM). Statistical Analysis: Analysis of variance (ANOVA) was applied for between-group analysis, followed by Tukey's post-hoc test. Result: A significant difference was observed in all groups (P<0.05). PDL2 instruments showed higher fracture resistance under H2O and 2.5% NaOCl conditions compared to TRU. Analysis of all instrument groups showed that exposure to 2.5% NaOCl decreased the NCF compared to H2O. Conclusion: Cyclic fatigue resistance of the TRU and PDL2 instruments was decreased by exposure to 2.5% NaOCl. PDL2 instruments were more resistant to fracture than TRU instruments.


Asunto(s)
Hipoclorito de Sodio , Titanio , Microscopía Electrónica de Rastreo , Análisis de Varianza , Instrumentos Dentales , Níquel , Tratamiento Térmico , Corrosión
4.
Dent. press endod ; 11(3): 31-39, Sept-Dec.2021. Tab, Ilus
Artículo en Inglés | LILACS | ID: biblio-1378948

RESUMEN

Introdução: O estudo da anatomia da raiz e do canal radicular tem importância relevante para o tratamento endodôntico. Portanto, o conhecimento da morfologia do canal radicular é essencial para se realizar um tratamento que resulte em sucesso. No entanto, o profissional tem limitada informação desses conhecimentos, e um acesso difícil ao local de atuação. Objetivo: O presente estudo teve por objetivo avaliar o número de canais de incisivos inferiores, visto que estudos realizados sobre o assunto apresentam uma alta taxa de incisivos inferiores com dois canais radiculares. Métodos: Para avaliar com detalhes a anatomia interna das raízes dos incisivos inferiores, foi utilizada a tomografia computadorizada de feixe cônico (TCFC) na observação dos canais radiculares, em dentes permanentes humanos. Foram analisadas 97 imagens tomográficas obtidas com um tomógrafo Orthopantomograph OP 300 (Instrumentarium, Tuusula, Finlândia) de pacientes que se submeteram ao exame por motivos diversos. Todos os grupos dentários foram avaliados individualmente, e sua morfologia interna foi determinada conforme a Classificação de Vertucci (1984). Resultados: Os resultados observados por meio do teste estatístico do qui-quadrado apresentaram maior frequência dos Tipos I e III (Classificação de Vertucci), em comparação aos outros tipos (p<0,001). Conclusão: Conclui-se que a TCFC é o recurso viável para auxiliar a prática endodôntica, especialmente em casos complexos, como a localização de canais radiculares. A ocorrência de mais de um canal em incisivos inferiores centrais e laterais foi de 23,71% nesse estudo realizado na população brasileira (AU).


Introduction: The study of root and rood canal anatomy is relevant for endodontic treatment. Therefore, knowledge of the root canal morphology is essential to achieve an end- odontic that results in success. However, the professional has limited information of this knowledge and difficult access to the place of performance. Objective: The present study aimed to evaluate the number of the canals of the mandibular incisors, since studies carried out on the subject present a high rate of mandibular incisors with two canals. Methods: In order to evaluate in detail the internal anatomy of the roots of incisors, the accuracy of the cone beam computed tomography in the observation of the root canals in human permanent teeth was evidenced in this study. We analized 97 tomographic images obtained using ORTHO-PANTOMOGRAPH OP 300 (Instrumentarium, Tuusula, FI) of patients who underwent the diagnostic procedure for several reasons. All dental groups were analyzed individually and the morphology was determined according Vertucci Classification (1984). Results: The results observed the Chi-Square statistical test presented higher frequency of Types I and III (Vertucci Criterion) in relation to the other types (p<0.001). Conclusion: It was concluded that computed tomography is the viable resource to aid endodontic practice, especially in complex cases, such as the location of the root canals. The occurrence of more than one canal in central and lateral lower incisors was 23,71% in this study performed in the Brazilian population (AU).


Asunto(s)
Humanos , Dentición Permanente , Cavidad Pulpar , Tomografía Computarizada de Haz Cónico , Incisivo , Proyectos de Investigación , Brasil , Anatomía
5.
Braz. dent. j ; 32(6): 16-27, Nov.-Dec. 2021. tab, graf
Artículo en Inglés | LILACS-Express | LILACS, BBO | ID: biblio-1355838

RESUMEN

Abstract This study assessed the influence of apical preparation size and final irrigation protocol on the debridement of the apical third of oval root canals of mandibular molars. Seventy-seven distal roots were divided into 7 groups (n = 11): Control: without instrumentation or irrigation; Group 30CI: ProTaper Next (up to size 30; PTN) + conventional irrigation (CI); Group 30UAI: PTN + ultrasonically activated irrigation (UAI); Group 30XPF: PTN + XP-endo Finisher (XPF); Group 40CI: PTN + ProDesign Logic (up to size 40; PDL) + CI; Group 40UAI: PTN + PDL + UAI; and Group 40XPF: PTN + PDL + XPF. The total volume of irrigating solutions used per root canal in all the experimental groups was 33 mL of 2.5% sodium hypochlorite (NaOCl) and 6 mL of 17% ethylenediaminetetraacetic acid (EDTA). After specimen processing and histological analysis under a digital microscope (100x), the percentages of untouched canal walls (UCW) and remaining debris (RD) were assessed using Image J software. A descriptive and exploratory analysis was conducted, indicating that the data failed to meet the assumptions of an analysis of variance. Therefore, generalized linear models were used to assess the effects of the different instrumentation and irrigation protocols, as well as the interaction among them, on the percentage of UCW and RD. No significant difference was found among the irrigation protocols regarding the percentage of UCW, irrespective of apical preparation size (p>0.05). However, UCW and RD were significantly lower in groups 40CI, 40UAI and 40XPF than in groups 30CI, 30UAI and 30XPF (p<0.05). The percentage of RD was significantly lower in the UAI and XPF groups than in the CI groups, irrespective of apical preparation size (p<0.05). The difference between preparation sizes 30 and 40, with respect to RD, was higher when CI was used (p<0.05). In conclusion, instrumentation up to apical preparation size 40 resulted in lower percentages of UCW and RD than up to apical preparation size 30. Use of UAI or XPF resulted in lower percentages of RD than CI.


Resumo Este estudo avaliou a influência do tamanho do preparo apical e do protocolo de irrigação final sobre o debridamento do terço apical de canais radiculares ovais de molares inferiores. Setenta e sete raízes distais foram selecionadas e divididas em 7 grupos (n = 11): Grupo controle: sem instrumentação nem irrigação; Grupo 30IC, ProTaper Next (até o tamanho 30; PTN) + irrigação convencional (IC); Grupo 30IAU, PTN + irrigação ativada ultrassonicamente (IAU); Grupo 30XPF, PTN + XP-endo Finisher (XPF); Grupo 40IC, PTN + ProDesign Logic (até o tamanho 40; PDL) + IC; Grupo 40IAU, PTN + PDL + IAU; e Grupo 40XPF, PTN + PDL + XPF. Os volumes totais dos irrigantes utilizados por canal radicular em todos os grupos experimentais foram 33 mL de hipoclorito de sódio (NaOCl) a 2,5% e 6 mL de ácido etilenodiamino tetracético (EDTA) a 17%. Após o processamento dos espécimes e a análise das secções histológicas sob um microscópio digital (100x), as porcentagens de paredes não instrumentadas (PNI) e detritos remanescentes (DR) foram avaliadas utilizando-se o software Image J. Uma análise descritiva e exploratória foi realizada, indicando que os dados não atenderam aos pressupostos de uma análise de variância. Modelos lineares generalizados foram, portanto, utilizados para avaliar os efeitos dos diferentes protocolos de instrumentação e irrigação, bem como da interação entre eles, sobre as porcentagens de PNI e DR. Não houve diferença significativa entre os protocolos de irrigação final quanto à porcentagem de PNI, independentemente do tamanho do preparo apical (p>0,05). Entretanto, as porcentagens de PNI e DR foram significativamente menores nos grupos 40IC, 40IAU e 40XPF do que nos grupos 30IC, 30IAU e 30XPF (p<0,05). A porcentagem de DR foi significativamente menor nos grupos em que se utilizou a IAU ou o XPF do que naqueles em que se utilizou a IC, independentemente do tamanho do preparo apical (p<0,05). A diferença entre os tamanhos de preparo apical 30 e 40 com relação aos DR foi maior quando se utilizou a IC (p<0,05). Concluiu-se que a instrumentação até um preparo apical de tamanho 40 resultou em menores porcentagens de PNI e DR do que até um preparo apical de tamanho 30. A utilização da IAU ou do XPF resultou em uma menor porcentagem de DR do que a utilização da IC.

6.
Dent. press endod ; 11(1): 46-53, Jan-Apr2021. Tab, Ilus
Artículo en Inglés | LILACS | ID: biblio-1348176

RESUMEN

Introdução: De todas as especialidades na Odontologia, uma das mais favorecidas nos últimos anos com o desenvolvimento de novas tecnologias tem sido a Endodontia. Objetivo: O presente estudo visou obter informações sobre os aspectos técnicos dos tratamentos endodônticos realizados por cirurgiões-dentistas da Polícia Militar do Estado de São Paulo (PMESP), dando ênfase aos materiais, técnicas e equipamentos empregados. Métodos: Um questionário com 25 questões de múltipla escolha foi enviado aos 147 dentistas da PMESP, e o critério de inclusão foi que os profissionais realizassem tratamentos endodônticos. Resultados: A análise estatística foi feita por meio do teste qui-quadrado, com p<0,05. Entre os 42 profissionais avaliados, 59,5% eram do sexo masculino, o dique de borracha foi utilizado em 54,8% dos casos, o comprimento de trabalho foi obtido por meio de radiografias em 71,4%, o sensor digital foi utilizado em 28,6%, a magnificação visual foi utilizada em 23,8% e a técnica de condensação lateral foi a mais utilizada, com 90,2%. Outra análise foi realizada com 10 especialistas do Centro Odontológico da PMESP que efetuavam unicamente tratamento endodôntico, sendo que 50% eram do sexo masculino e tratavam mais de 15 casos/mês: o dique de borracha foi utilizado em 80% dos casos; o comprimento de trabalho foi obtido com localizador foraminal em 50% dos casos; o sensor digital foi utilizado em 90%, assim como o motor elétrico; a técnica de condensação lateral foi utilizada em 60% dos casos e o ultrassom, em 20%. Conclusões: Conclui-se que os especialistas utilizaram mais as novas tecnologias, e que o ultrassom e a magnificação visual foram pouco utilizados em ambos os grupos (AU).


Introduction: Of all the specialties in dentistry, one of the most favored in recent years with the development of new technologies has been endodontics. Objective: This study aimed to obtain information on the technical aspects of endodontic treatments performed by dentists from the Military Police of the State of São Paulo, emphasizing the materials, equipment, and techniques used. Methods: A questionnaire with 25 multiple choice questions was sent to 147 dentists from PMESP and the inclusion criterion was professionals who performed endodontic treatment. Results: The statistical analysis was done through the chi-square test, with p< 0.05. The professionals evaluated 59.5% were male, the rubber dam was used in 54.8% of the cases, the working length by means of radiographs was obtained in 71.4%, the digital sensor was used in 28.6%, the visual magnification was used in 23.8% and the lateral condensation technique was the most used with 90.2%. Another analysis was performed with 10 specialists of the Dental Center who performed only endodontic treatment, 50% were male, treated more than 15 cases/month, the rubber dike was used in 80% of the cases, the working length was performed in 50% of the cases by foraminal locator, the digital sensor was used in 90%, as well as the electric motor, the technique of lateral condensation was used in 60% of the cases and ultrasound 20%. Conclusion: It was concluded that the specialists used more new technologies and that the use of ultrasound and visual magnification was little used in both groups (AU).


Asunto(s)
Humanos , Masculino , Femenino , Tecnología , Encuestas y Cuestionarios , Odontólogos , Endodoncia , Dique de Goma
7.
Braz. oral res. (Online) ; 35: e080, 2021. graf
Artículo en Inglés | LILACS, BBO | ID: biblio-1278598

RESUMEN

Abstract: This research evaluated, in vivo, the accuracy of three electronic apex locators - EALs (Root ZXII, E-PEX and FIND) in teeth with vital pulp submitted to biopulpectomy, preserving the periodontal stump. For this study, 90 single-rooted teeth with extraction indication were selected. After positive pulpal cold sensitivity test, pulp chamber access was performed. The cervical and middle thirds of root canals were instrumented with Reciproc R25, and the K#15 file was used as a standard instrument to determine working length, forming 2 groups: Constriction (insertion of the instrument until the apical constriction limit) and Foramen (insertion of the instrument until the foramen and then repositioning at constriction, without removing the file from the canal). The hand file was stabilized with a light-cured flow resin. After extraction, the samples were analyzed through microCT SkyScan 1272, with CTAN software, which evaluated the proximity between the tip of the file to the apical constriction, providing data for comparative analysis using Kruskal-Wallis and Dunn tests (p<0.05). There was a statistically significant difference in the abilities of the EALs to detect the apical constriction after reaching the foramen with Root ZX II showing higher accuracy (89%). However, there was no difference in the accuracy of the three EALs in detecting the apical constriction without reaching the foramen. Based on the present results, we conclude that EALs may show accurate measures in detecting apical constriction and foramen, even without damaging the periodontal stump in biopulpectomy.


Asunto(s)
Ápice del Diente/diagnóstico por imagen , Cavidad Pulpar , Raíz del Diente , Preparación del Conducto Radicular , Microtomografía por Rayos X , Odontometría
8.
Braz. dent. j ; 31(5): 477-484, Sept.-Oct. 2020. tab, graf
Artículo en Inglés | LILACS, BBO | ID: biblio-1132331

RESUMEN

Abstract This study evaluated the biocompatibility, biomineralization, and collagen fiber maturation induced by Resorbable Tissue Replacement (RTR®; β-tricalcium phosphate [TCP]), Bioglass (BIOG; bioactive glass), and DM Bone® (DMB; hydroxyapatite and β-TCP) in vivo. Sixty-four polyethylene tubes with or without (control group; CG) materials (n=8/group/period) were randomly implanted in the subcutaneous tissue of 16 male Wistar rats (four per rat), weighting 250 to 280 g. The rats were killed after 7 and 30 days (n=8), and the specimens were removed for analysis of inflammation using hematoxylin-eosin; biomineralization assay using von Kossa (VK) staining and polarized light (PL); and collagen fiber maturation using picrosirius red (PSR). Nonparametric data were statistically analyzed by Kruskal-Wallis and Dunn tests, and parametric data by one-way ANOVA test (p<0.05). At 7 days, all groups induced moderate inflammation (p>0.05). At 30 days, there was mild inflammation in the BIOG and CG, and moderate inflammation in the RTR and DMB groups, with a significant difference between the CG and RTR (p<0.05). The fibrous capsule was thick at 7 days and predominantly thin at 30 days in all groups. All materials exhibited structures that stained positively for VK and PL. Immature collagen fibers were predominant at 7 and 30 days in all groups (p>0.05), although DMB exhibited more mature fibers than BIOG at 30 days (p<0.05). RTR, BIOG, and DMB were biocompatible, inducing inflammation that reduced over time and biomineralization in the subcutaneous tissue of rats. DMB exhibited more mature collagen fibers than BIOG over a longer period.


Resumo Este estudo avaliou a biocompatibilidade, biomineralização e maturação das fibras de colágeno induzidas por Resorbable Tissue Replacement (RTR®; fosfato β-tricálcico [TCP]), Bioglass (BIOG; vidro bioativo) e DM Bone® (DMB; hidroxiapatita e β-TCP) in vivo. Sessenta e quatro tubos de polietileno com ou sem (grupo controle; GC) os materiais (n=8/grupo/período) foram implantados aleatoriamente em tecido subcutâneo de 16 ratos machos Wistar (quatro por rato), pesando entre 250 a 280g. Os ratos foram mortos após 7 e 30 dias (n=8), e as amostras foram removidas para análise da inflamação utilizando hematoxilina-eosina; avaliação da biomineralização utilizando coloração de von Kossa (VK) e luz polarizada (LP); e maturação das fibras colágenas, utilizando picrosirius red (PSR). Os dados não-paramétricos foram analisados pelos testes de Kruskal-Wallis e Dunn, e os paramétricos pelo teste de one-way ANOVA (p<0.05). Aos 7 dias, todos os grupos induziram inflamação moderada (p>0,05). Aos 30 dias, houve inflamação leve nos grupos BIOG e GC, e inflamação moderada nos grupos RTR e DMB, com diferença significativa entre os GC e RTR (p<0,05). A cápsula fibrosa foi espessa aos 7 dias, e predominantemente fina aos 30 dias em todos os grupos. Todos os materiais exibiram estruturas positivas para VK e LP. Fibras colágenas imaturas foram predominantes aos 7 e 30 dias em todos os grupos (p>0,05), embora o DMB exibiu fibras mais maduras do que o BIOG aos 30 dias (p<0,05). RTR, BIOG e DMB foram biocompatíveis, induzindo inflamação que reduziu com o tempo, e biomineralização no tecido subcutâneo de ratos. O DMB exibiu mais fibras colágenas maduras do que o BIOG em período mais longo.


Asunto(s)
Animales , Masculino , Ratas , Materiales de Obturación del Conducto Radicular , Biomineralización , Óxidos , Materiales Biocompatibles , Ensayo de Materiales , Cerámica , Colágeno , Ratas Wistar , Silicatos , Compuestos de Calcio , Compuestos de Aluminio , Tejido Subcutáneo
9.
Dent. press endod ; 10(2): 34-41, maio-ago.2020. Tab, Ilus
Artículo en Inglés | LILACS | ID: biblio-1344542

RESUMEN

Objetivo: Avaliar a influência de diferentes plugs de proteção, acomodados sobre o remanescente da obturação após preparo para pino, na retenção de pinos metálicos fundidos. Métodos: Cinquenta dentes bovinos foram decoronados, manualmente instrumentados até a lima manual Kerr #80 e obturados. A desobturação parcial de 10mm do conduto foi realizada com uma broca Largo e os grupos foram divididos de acordo com os diferentes materiais utilizados como plugs (n=10): Grupo I (Controle, sem plug); Grupo II (plug de Coltosol®); Grupo III (plug, em consistência de massa, de Sealapex® + óxido de zinco); Grupo IV (plug de etil-cianoacrilato); e Grupo V (plug de fosfato de zinco). Uma camada de 1mm de espessura dos diferentes plugs (Grupos II, III, IV ou V) foi acomodada sobre a obturação remanescente. Os espécimes foram selados e armazenados em 100% de umidade, por 7 dias. Após moldagem do conduto, foram confeccionados pinos metálicos fundidos e cimentados com fosfato de zinco. Os espécimes permaneceram em câmara úmida por 45 dias antes do teste de tração, realizado em uma máquina universal de ensaios. Os valores foram expressos em Mega pascal (MPa) e submetidos aos testes ANOVA e Tukey (p<0,05). Resultados: O etilcianoacrilato diminuiu a retenção dos pinos metálicos fundidos (p<0,01). Não houve diferença entre os outros grupos (p>0,05), semelhante- mente ao controle. Conclusão: A proteção da obturação com plugs confeccionados com etil-cianoacrilato prejudica a retenção de pinos metálicos fundidos cimentados com fosfato de zinco, enquanto Sealapex® acrescido de óxido de zinco, fosfato de zinco endurecido ou Coltosol® não interferem na adesividade (AU).


Asunto(s)
Animales , Bovinos , Cementación , Cavidad Pulpar , Endodoncia , Tracción , Óxido de Zinc , Técnicas In Vitro , Adhesividad
10.
Medicina (B.Aires) ; 80(supl.2): 2-6, mar. 2020. ilus
Artículo en Español | LILACS | ID: biblio-1125097

RESUMEN

Los trastornos heredados del metabolismo son enfermedades graves de la infancia que cursan con un gran deterioro cognitivo y del desarrollo psicomotor. La fisiopatología del progresivo deterioro del sistema nervioso suele estar asociada a una severa neuroinflamación y desmielinización, y como consecuencia, neurodegeneración. Por el momento no tienen cura y precisan de actitudes terapéuticas precoces y agresivas, que conllevan altas tasas de mortalidad y, muy frecuentemente, escasos grados de mejoría funcional y supervivencia. El trasplante de médula ósea y de células mesenquimales de médula ósea son terapias de elección y experimentales que consiguen mejorar el curso de estas enfermedades mediante diferentes mecanismos de acción: remplazo de enzima deficiente, intercambio de membranas y regulación del proceso inflamatorio.


Inherited metabolism disorders are serious childhood diseases that lead to significant cognitive impairment and regression of psychomotor development. The pathophysiology of the neural progressive deterioration is usually associated with severe neuroinflammation and demyelination, and as a consequence, neurodegeneration. At the moment they have no adequate treatment and require early and aggressive therapeutic approaches, which entail high mortality rates and, very frequently, low degrees of functional improvement and survival. Bone marrow transplantation and bone marrow mesenchymal cells grafts are therapeutic and experimental therapies that improve the course of these diseases through different mechanisms of action: enzyme replacement, membrane exchange and regulation of the inflammatory process.


Asunto(s)
Humanos , Trasplante de Médula Ósea/métodos , Enfermedades por Almacenamiento Lisosomal/terapia , Trastorno Peroxisomal/terapia , Enfermedades por Almacenamiento Lisosomal/fisiopatología , Trastorno Peroxisomal/fisiopatología , Trasplante de Células Madre Mesenquimatosas/métodos
11.
Dent. press endod ; 9(3): 82-88, Sept-Dec.2019. Ilus
Artículo en Inglés | LILACS | ID: biblio-1343991

RESUMEN

Objetivo: apresentar o relato de um caso de tratamento viável para molar inferior permanente endodonticamente tratado que apresentou sintomatologia após 6 meses do tratamento endodôntico. Uma vez que retratamento endodôntico ou cirurgia parendodôntica não eram indicados, o reimplante intencional foi a técnica escolhida. Relato de caso: uma hora antes do procedimento, o paciente fez bochecho com gluconato de clorexidina a 0,12% e foi preparado para cirurgia com anestesia dos nervos alveolar inferior e lingual, realizada com mepivacaína 2% contendo 1:100.000 de adrenalina. O procedimento teve início com extração menos traumática possível, envolvendo-se imediatamente o dente extraído em gaze umedecida com soro fisiológico, enquanto as raízes foram avaliadas para presença de fraturas, seguida da apicectomia. As cavidades foram retroinstrumentadas com broca de alta rotação sob irrigação com soro fisiológico e, para a retro-obturação, foi utilizado agregado de trióxido mineral (MTA) branco. Imediatamente, o dente foi reposicionado no alvéolo e estabilizado por suturas com fio de seda 4-0. Após um ano, o paciente retornou para controle radiográfico e clínico, o qual não revelou mais resposta à percussão vertical. Após 10 anos, a imagem radiográfica mostra reparo apical, sem indícios de reabsorção radicular ou lesão periapical. Conclusão: o exame clínico, associado à ausência dor e mobilidade normal do dente, confirmou o sucesso do tratamento, indicando esse como uma alternativa válida quando o implante não for acessível para o paciente. Essa técnica pode ajudar a restaurar a função de um dente original, em vez de substituí-lo por prótese ou implante dentário (AU).


Objective: This case report shows a successful viable treatment for an endodontically treated permanent mandibular molar which presented clinical symptoms 6 months after the endodontic treatment. Since endodontic retreatment or paraendodontic surgery were not indicated, the chosen technique was intentional replantation. Case Report: One hour before the procedure, the patient rinsed his mouth with chlorhexidine gluconate 0.12%. The patient was prepared for surgery and profound inferior alveolar and lingual nerve block anesthesia was achieved with 2% mepivacaine containing 1/100,000 adrenaline. The procedure started with the least traumatic extraction as possible and immediately wrapping the extracted tooth in physiological saline-moistened gauze, while the roots were evaluated for vertical fractures, followed by apicoectomy. The cavities were retro-prepared with high-speed bur under irrigation with physiological saline and white mineral trioxide aggregate (MTA) was used for retrofilling. Immediately, the tooth was repositioned in the alveolus. Two 4-0 silk sutures were used to suture and stabilize the tooth. After one year, the patient returned for radiographic and clinical control, which revealed no more response to vertical percussion. After 10 years, the images show radiographic apical repair, without evidence of root resorption or periapical lesion. Conclusion: Clinical examination associated with the reported absence of pain and normal mobility confirmed the procedure's success, indicating this treatment as a valid alternative when an implant is not viable. This technique may help restore an original tooth to function instead of replacing it with a prosthetic or a dental implant (AU).


Asunto(s)
Humanos , Apicectomía , Reimplante Dental , Clorhexidina , Prótesis e Implantes , Ápice del Diente , Diente Molar
12.
Rev. bras. ciênc. esporte ; 41(3): 284-289, jul.-set. 2019.
Artículo en Portugués | LILACS | ID: biblio-1042072

RESUMEN

Resumo Em meio às obras que tomam parte no corpo de conhecimentos produzido pelo confucionismo figuram o Registro dos ritos (Liji) e Discursos (Zhonglun). No presente estudo, buscamos investigar como manifestações da cultura corporal são apresentadas nas referidas obras e o que tais formas de atividades poderiam representar frente ao processo formativo de um indivíduo no contexto de produção desses escritos, conforme o prisma confuciano. Foram identificadas como relevantes para essa discussão informações a respeito da prática de arquearia, presentes no Registro dos ritos, assim como o conceito das Seis Artes, presente na obra Discursos.


Abstract Among the writings that constitute the body of knowledge produced by the Confucianism, one can mention the "Book of Rites" (Liji) and "Discourses" (Zhonglun). In this study, we aim to investigate how these books portray physical culture manifestations and what such type of activities could represent to the formative process of an individual, accordingly with the confucian approach, in the context in which these works were first written. We have considered as relevant issues for this discussion the information regarding the practice of archery included in the Book of Rites, as well as the concept of the "Six Arts", included in the Discourses.


Resumen Entre las obras que forman parte del conjunto de conocimientos producido por el confucianismo se encuentran el Libro de los ritos (Liji) y Discursos (Zhonglun). En el presente estudio queremos investigar cómo las manifestaciones de la cultura corporal se presentan en estas obras y lo que podrían representar estas formas de actividades en el proceso formativo de un individuo en el contexto en que se escribieron estas obras, conforme al prisma confuciano. Se identificaron como relevantes para esa discusión informaciones acerca de la práctica del tiro con arco, presente en el Libro de los ritos, así como el concepto de las «seis artes¼, presente en la obra Discursos.

13.
Medicina (B.Aires) ; 79(1,supl.1): 27-32, abr. 2019. ilus, tab
Artículo en Español | LILACS | ID: biblio-1002601

RESUMEN

Los trastornos del espectro autista (TEA) son una alteración funcional de la corteza cerebral, que presenta anomalías estructurales del neurodesarrollo que afectan fundamentalmente a la función sináptica y el patrón de conexiones dentro y entre columnas corticales. Desde su aspecto etiológico, el TEA tiene una importante carga genética, considerándose un desorden derivado de una combinación de mutaciones "de novo", asociadas a una predisposición derivada de variaciones comunes heredadas. Las principales anomalías genéticas asociadas a TEA implican genes que codifican proteínas de la sinapsis. Así, en pacientes con TEA se han descrito alteraciones del desarrollo inicial de las sinapsis en los circuitos de conexión entre áreas corticales de procesamiento complejo. La complejidad molecular observada en la predisposición a desarrollar un TEA, junto con la diversidad de fenotipos estructurales neuronales, ha hecho que los modelos animales reproduzcan solo parcialmente el TEA. Para avanzar en el estudio experimental se hace pues necesario desarrollar modelos más representativos, como son los modelos celulares derivados de células humanas. En las últimas décadas, el desarrollo de la biología de las células madre nos da medios para acceder a paradigmas experimentales sobre células derivadas de individuos con TEA. Actualmente, los modelos de células plutipotentes inducidas (IPs) derivadas de células humanas permiten profundizar en el estudio de las bases moleculares y celulares del TEA. Sin embargo, presentan problemas inherentes derivados de la manipulación experimental que conlleva la reprogramación de la expresión génica, por lo que otros modelos celulares se están también postulando como válidos.


Autism Spectrum Disorders (ASD) are a functional alteration of the cerebral cortex, which presents structural neurodevelopmental anomalies that affect synaptic function and the pattern of connections within and between cortical columns. From its etiological aspect, ASD has an important genetic load, considering a polygenic disorder, derived from a combination of "de novo" genetic mutations, associated to a predisposition derived from common inherited variations. The main genetic anomalies associated with ASD involve genes that encode proteins of the synapse. Thus, in patients with ASD, alterations in the initial development of the synapses have been described in the connection circuits between complex processing cortical areas. The molecular complexity observed in the predisposition to develop an ASD, together with the diversity of structural phenotypes, has made animal models reproduce only partially the ASD. To advance in the experimental study it is therefore necessary to develop representative models, such as cellular models derived from human cells. In recent decades, the advances in stem cell biology give us a way to apply experimental paradigms in cells derived from individuals with ASD. Currently, induced pluripotent cells (IPs) derived from human adult cells allow deepening the study of molecular and cellular bases of the neuronal development in humans, as well as the anomalies in this development, which give rise to disorders such as ASD. However, they present inherent problems derived from the experimental manipulation that involves the reprogramming of gene expression, therefore other models are also been explored.


Asunto(s)
Humanos , Trastorno del Espectro Autista/fisiopatología , Modelos Biológicos , Sinapsis/fisiología , Sinapsis/genética , Expresión Génica , Predisposición Genética a la Enfermedad/genética , Epigénesis Genética/genética , Células Madre Pluripotentes Inducidas/citología , Trastornos del Neurodesarrollo/fisiopatología , Trastorno del Espectro Autista/genética
14.
Araçatuba; s.n; 2019. 72 p. ilus, tab.
Tesis en Inglés, Portugués | LILACS, BBO | ID: biblio-1051325

RESUMEN

Introdução: O tratamento endodôntico visa manter ou restabelecer a saúde do periodonto através do preparo biomecânico, utilizando instrumentos de níqueltitânio automatizados e associados com insertos ultrassônicos para potencializar a ação dos irrigantes. Os materiais empregados na endodontia que permanecerão em contato com tecidos devem apresentar biocompatibilidade e preferencialmente ser biomineralizador, a fim de selar comunicações (fisiológicas/iatrogênicas), isolando o sistema de canais radiculares. Objetivos: 1- Avaliar a resistência à fadiga cíclica das limas reciprocantes Genius e EdgeFile X1 Small, comparados à lima WaveOne Gold Primary; 2- Avaliar a capacidade de limpeza de um inserto ultrassônico de níquel titânio em ativação da irrigação de forma contínua e passiva; 3- Avaliar a biocompatiblidade e biomineralização do cimento reparador MTA Flow. Material e Métodos: Para avaliar a resistência à fadiga cíclica dos sistemas Genius, EdgeFile e WaveOne Gold, 80 instrumentos foram utilizados (n=20), divididos em 4 grupos experimentais: Genius 25.04, Genius 30.04; EdgeFile X1 Small e Wave One Gold Primary, acionados em um canal artificial de aço inoxidável com ângulo de curvatura de 60o e raio de curvatura de 5 mm. O tempo decorrido da ativação do motor foi gravado em um cronômetro digital e parado assim que a fratura foi detectada. O número de ciclos até a falha (NCF) e o tempo para fratura (TF) foram calculados e os comprimentos dos segmentos fraturados medidos. Para avaliar a capacidade de limpeza do inserto ultrassônico, 45 prémolares inferiores, padronizados em 16 mm foram utilizados. A instrumentação foi realizada até lima 50.04 sob irrigação com hipoclorito de sódio e foram divididos em 3 grupos (n = 15) de acordo com a técnica de ativação final da solução irrigadora: irrigação convencional (IC) (passiva com pressão positiva/sucção concomitante) como controle; ativação ultrassônica passiva (PUI) e ativação ultrassônica contínua (CUI) do irrigante. Os três grupos tiveram os protocolos de ativação/irrigação final em soluções de hipoclorito de sódio e EDTA. As amostras foram clivadas, as imagens obtidas com microscopia eletrônica de varredura (MEV) e avaliadas quanto à capacidade de remoção da camada de smear layer no terço cervical, médio e apical, por um sistema de escores. Para análise biológica do material reparador MTA Flow, os materiais MTA Angelus e ProRoot MTA foram utilizados para comparação. Quarenta ratos receberam implantes subcutâneo de tubos de polietileno contendo os 3 materiais e tubo vazio como controle (n=10). Após 7, 15, 30 e 60 dias, os animais foram eutanasiados e os tubos removidos com o tecido conjuntivo circundantes. Infiltrado inflamatório e espessura da cápsula fibrosa foram avaliados histologicamente e indução da mineralização analisada por Von Kossa e sob luz polarizada. Os dados foram analisados com testes estatísticos específicos (p<5%). Resultados: Quanto à fadiga cíclica, os instrumentos EdgeFile X1 Small apresentaram maior resistência (NCF: 6175.74 ± 1608.99; TF: 1058.7 ± 275.82), seguido por ambos instrumentos Genius (p<0.05), de forma significativa comparados ao Waveone Gold Primary. O inserto de NiTi aumentou a limpeza, comparado com IC, principalmente no terço apical e CUI mostrou os melhores resultados (p<0.05). Nos resultados biológicos, MTA Angelus induziu a reação mais leve após 15 dias (p<0.05), seguido do MTA Flow. ProRoot MTA induziu uma inflamação severa no dia 7, reduzindo após 15 dias. Nenhuma diferença foi observada entre os materiais após 30 ou 60 dias (p>0.05). Estruturas coradas por Von Kossa e birrefringentes foram positivas para todos os materiais. Conclusões: 1- Os instrumentos EdgeFile X1 Small demonstraram maior resistência à fadiga cíclica que Genius e WaveOne Gold Primary. Ambos instrumentos Genius apresentaram resistência superior à WaveOne Gold Primary. 2- A ativação final do irrigante com o inserto NiTi melhorou a remoção de smear layer, com protocolo CUI superior à PUI ou IC. 3- O MTA Flow mostrou biocompatibilidade e induziu a biomineralização em todos os períodos observados(AU)


Introduction: The endodontic treatment aims to maintain or restore periodontal health through biomechanical instrumentation with nickel-titanium automatized instruments, associated with an ultrasonic tip to activate the irrigant, enhancing cleanness. Materials used in endodontics that will remain in contact with tissues, should demonstrate properties as biocompatibility and biomineralization ability, in order to seal communications (physiological/iatrogenic) isolating the root canal system. Objectives: 1- Evaluate the cyclic fatigue resistance of reciprocating Genius and EdgeFile X1 Small instruments compared to Waveone Gold Primary instruments; 2- Evaluate the cleaning effectiveness of a nickel-titanium ultrasonic tip in continuous and passive irrigant activation; 3-Evaluate the biocompatibility and biomineralization of MTA Flow repair cement. Materials and Methods: To evaluate the cyclic fatigue resistance of Genius, EdgeFile and WaveOne Gold, 80 instruments were used (n = 20), divided into 4 experimental groups: Genius 25.04, Genius 30.04; EdgeFile X1 Small and Wave One Gold Primary, reciprocating in a stainless steel artificial canal with a 60° angle of curvature and 5mm radius of curvature. The elapsed time of the motor activation was recorded in a digital timer and stopped as soon as the fracture was detected. The number of cycles to fracture (NCF) and time to fracture (TF) were calculated and the fractured segments lengths measured. To evaluate the ultrasonic tip cleanness capacity, forty-five mandibular premolars, standardized at 16 mm were used. The instrumentation was performed until file 50.04 under irrigation with sodium hypochlorite. The specimens were divided into 3 groups (n = 15) according to the final irrigant activation protocol: conventional irrigation (CI) (passive, with positive pressure/simultaneous aspiration) as control; passive ultrasonic irrigant activation (PUI) and continuous ultrasonic irrigant activation (CUI). All groups had the final activation / irrigation protocols with solutions of sodium hypochlorite and EDTA, standardized with same volume. Samples were sodium hypochlorite and EDTA, standardized with same volume. Samples were cleaved and images obtained through scanning electron microscopy (SEM) to assess smear layer removal in the cervical, middle and apical thirds, via a score system. To biologically analyze MTA Flow repair cement, MTA Angelus and ProRoot MTA cements were used as comparison. Forty rats received subcutaneous implants of polyethylene tubes containing the 3 cements and empty tube as control (n = 10). After days 7, 15, 30 and 60, the animals were euthanized and the tubes removed with the surrounding tissues. Inflammatory infiltrate and fibrous capsule thickness were histologically evaluated and mineralization induction assessed by Von Kossa staining and under polarized light. The data were analyzed with specific statistical tests (p<5%). Results: The cyclic fatigue test showed EdgeFile X1 Small with the highest resistance (NCF: 6175.74 ± 1608.99; TF: 1058.7 ± 275.82), followed by both Genius instruments (p<0.05). The nickel-titanium tip enhanced cleanness, compared to CI, mainly in the apical area, whereas CUI showed the best results (p<0.05). In the biological results, MTA Angelus induced the mildest reaction after 7 (p>0.05) and 15 days (p<0.05), followed by MTA Flow. ProRoot MTA induced severe inflammation on day 7, reducing after day 15 (p>0.05). No difference was observed after 30 or 60 days (p>0.05). Von Kossa staining and birefringents structures were positive for all materials. Conclusion: 1- EdgeFile X1 Small instruments demonstrated superior cyclic fatigue resistance than Genius and WaveOne Gold Primary. In addition, both Genius instruments showed superior resistance than WaveOne Gold Primary. 2- The final irrigant activation with the NiTi tip improved smear layer removal, with CUI protocol superior to PUI or CI. 3 - MTA Flow showed biocompatibility and induced biomineralization in all observed periods(AU)


Asunto(s)
Ratas , Tratamiento del Conducto Radicular , Ensayo de Materiales , Ultrasonido , Materiales Biocompatibles , Ratas Wistar , Endodoncia , Biomineralización , Inflamación
15.
Braz. oral res. (Online) ; 33: e017, 2019. tab, graf
Artículo en Inglés | LILACS | ID: biblio-989481

RESUMEN

Abstract In endodontic treatment, regardless of the instrumentation technique, the presence of a smear layer covering contaminated dentin walls is always a concern. Thus, irrigation plays an essential role in reducing bacterial load. To enhance irrigation effectiveness, different ultrasonic activation methods and the use of different tips have been studied. This study assessed the cleaning capacity of the novel NiTi ultrasonic tip for smear layer removal using ultrasonically activated irrigation (UAI) with passive or continuous ultrasonic irrigation (PUI or CUI, respectively), compared with conventional irrigation. Forty-five single-rooted human mandibular premolars were decoronated to a standardized length of 16 mm. Instrumentation was performed using the Genius system up to size 50.04 and irrigated with 3% NaOCl. The specimens were divided into three groups (n = 15) according to the final irrigation activation technique: conventional irrigation (CI), as control group; PUI; and CUI, following the manufacturer's protocol. The samples were longitudinally cleaved and analyzed under a scanning electron microscope for smear layer removal according to a cleanliness score for the cervical, middle, and apical thirds. Data were evaluated by means of the Kruskal-Wallis and Tukey's tests, with a 5% level of significance. UAI enhanced cleaning compared to conventional irrigation, mainly at the apical third. CUI showed the best results, with statistically significant lower scores than PUI and CI (p < 0.05). Final irrigant activation with the NiTi tip showed better cleaning capacity than conventional irrigation. In addition, CUI resulted in better smear layer removal than PUI.


Asunto(s)
Humanos , Irrigantes del Conducto Radicular/uso terapéutico , Terapéutica/métodos , Titanio , Profilaxis Dental/métodos , Cavidad Pulpar , Níquel , Irrigación Terapéutica/instrumentación , Irrigación Terapéutica/métodos
16.
Acta odontol. latinoam ; 31(1): 11-15, 2018. tab, graf
Artículo en Inglés | LILACS | ID: biblio-909925

RESUMEN

The aim of this study was to evaluate the cytotoxic effects of 2.5% sodium hypochlorite (NaOCl), 17% ethylenediamine tetraacetic acid (EDTA), and 1% peracetic acid (PAA) on human fibroblasts. FG11 and FG15 cell lines were cultured in 24well cell culture plates for cell proliferation assessment and 96well cell culture plates for the methylthiazolyldiphenyltetrazolium bromide (MTT) assay; Dulbecco's modified Eagle's medium (DMEM) was used as control data. The experimental solutions were used at 0.01%, 0.05%, and 0.1% dilutions and assessed at 1, 2, and 4hour intervals. Data were subjected to statistical analysis by twoway analysis of variance (ANOVA), followed by the Bonferroni test at a significance level of p <0.05. The assessment of cell proliferation in this study showed cytotoxicity to the fibroblasts with 2.5% NaOCl for all three dilutions at all time intervals, 17% EDTA for the 0.05% and 0.1% dilutions at the 2and 4hour intervals, and 1% PAA for all three dilutions at the 4hour interval. The cell viability assay (MTT assay) for fibroblasts showed 2.5% NaOCl to be cytotoxic at the 0.05% and 0.1% dilutions at all time intervals, 17% EDTA to be cytotoxic at the 0.1% dilution at the 2and 4hour intervals, and 1% PAA to be cytotoxic at the 0.1% dilution at the 2and 4hour intervals. In conclusion, 1% PAA was less cytotoxic than 2.5% NaOCl and 17% EDTA (AU)


O objetivo do presente estudo foi o de avaliar os efeitos citotóxicos de hipoclorito de sódio (NaOCl) a 2,5%, ácido etilenodiaminotetracético (EDTA) a 17% e ácido peracético (PAA) a 1% em fibroblastos humanos. As linhagens celulares FG11 e FG15 foram colonizadas em 24well cell plates para avaliação da proliferação celularr e em 96well cell plates para o ensaio de MTT; O médio modificado Dulbecco's Eagle's (DMEM) foi usado como controle. As soluções experimentais foram usadas com diluições de 0,01%, 0.05%, e 0,1% e avaliadas com 1, 2 e 4 horas de intervalo. Os dados foram submetidos à análise estatística pelo twoway ANOVA, seguido do teste de Bonferroni com nível de significância de p <0.05. A avaliação da proliferação celular neste estudo mostrou o NaOCL a 2,5% como citotóxico nas 3 diluições e 3 intervalos de tempo, o EDTA a 17% nas diluições de 0,05% e 0,1% nos intervalos de 2 e 4 horas, e o PAA a 1% em todas as diluições no intervalo de 4 horas. O teste de viabilidade cellular (MTT) mostrou o NaOCl a 2,5% citotóxico a 0,05% e 0,1% em todos os intervalos, o EDTA a 17% citotóxico nas diluições de 0,1% nos intervalos de 2 e 4 horas e o PAA a 1% citotóxico na diluição de 0,1% nos intervalos de 2 e 4 horas. Como conclusão o PAA a 1% mostrouse menos citotóxico que o NaOCl a 2,5% e o EDTA a 17% (AU)


Asunto(s)
Humanos , Ácido Peracético , Hipoclorito de Sodio , Ácido Edético , Citotoxinas , Fibroblastos , Factores de Tiempo , Supervivencia Celular , Interpretación Estadística de Datos , Análisis de Varianza , Medios de Cultivo
17.
Braz. oral res. (Online) ; 32: e42, 2018. tab, graf
Artículo en Inglés | LILACS | ID: biblio-889494

RESUMEN

Abstract: Based on aroeira's (Myracrodruon urundeuva) antimicrobial activity and a future trend to compose intracanal medication, the aim of this study was to assess in vivo inflamatory tissue response to the extracts by edemogenic and histological analysis containing inactivated facultative and anaerobic microorganisms. For edema quantification, eighteen animals were divided into three groups (n = 3, periods: 3 and 6 hours) and 0.2 mL of 1% Evans blue per 100 g of body weight was injected into the penile vein under general anesthesia. After 30 min the animals received a subcutaneous injection in the dorsal region of aqueous or ethanolic extract of aroeira or saline (control) containing inactivated bacteria. Samples were collected, immersed in formamide for 72h, and evaluated by spectrophotometry (630 m). For histological analysis, polyethylene tubes with the extracts were implanted in the dorsal of 30 male rats. Analysis of the fibrous capsule and inflammatory infiltrate were performed after 7 and 30 days. The aqueous extract group induced less edema in both postoperative periods compared to the other groups, but the differences were not significant (p > 0.05). Tissue repair was significantly better after 30 days than after 7 days (p < 0.01). The aqueous solution showed less inflammatory response than the ethanolic solution (p < 0.05), with tendency for better results than control after 7 days. After 30 days, the response to both extracts was similar to control. The aqueous and ethanolic aroeira extracts containing inactivated microorganisms showed a trend for better results than saline, even when associated with microorganisms, and facilitated the tissue repair process.


Asunto(s)
Animales , Masculino , Ratas , Anacardiaceae/química , Edema/prevención & control , Bacterias Gramnegativas/efectos de los fármacos , Bacterias Grampositivas/efectos de los fármacos , Inflamación/prevención & control , Extractos Vegetales/farmacología , Tejido Subcutáneo/microbiología , Edema/patología , Bacterias Gramnegativas/clasificación , Bacterias Grampositivas/clasificación , Inflamación/patología , Ratas Wistar , Tejido Subcutáneo/efectos de los fármacos , Tejido Subcutáneo/patología , Factores de Tiempo
18.
Braz. dent. sci ; 21(2): 157-163, 2018. tab, ilus
Artículo en Inglés | LILACS, BBO | ID: biblio-906057

RESUMEN

Objective: The at-home bleaching technique leads to the intimate contact of the bleaching gel with gingival tissues, so this study evaluated the immediate inflammatory response, through the edemogenic test, induced by at-home bleaching gels of 10% carbamide peroxide with different desensitizing agents, the quantification of hydrogen peroxide released and bleaching gels pH. Material and Methods: Forty-eight rats were divided into groups (n=12): CTRL-control group, WP-Whiteness Perfect 10% (FGM Produtos Odontológicos, Joinville, SC, Brazil), OPA-Opalescence 10% (Ultradent Products Inc., South Jordan, IT, USA), and PB-Power Bleaching (BM4, Palhoça, SC, Brazil). For the edemogenic test, all rats received an intravenous injection of Evan's Blue; after 30 min, 0.2 mL of each bleaching gels was injected into the subcutaneous tissue of the rats, and the results of the vascular permeability were assessed after 3 and 6h. The amount of HP released and pH of each product was also determined. Data were submitted to statistical test (p <0.05 ). Results: At 3h, the PB showed higher vascular permeability than the other groups. At 6h, the PB produced similar vascular permeability than WHI, and higher than OPA and CTRL groups. The OPA group had a higher vascular permeability at 6h compared to 3h; there is no difference in other groups. The PB group had higher HP concentrations than the other groups. Conclusion: In general, the PB caused a more considerable amount of inflammatory edema and higher amount of HP released. This results suggesting that these bleaching gels cause greater aggression in soft gingival tissues that eventually ends up in contact with bleaching products. (AU)


Objetivo: A técnica de clareamento domiciliar leva ao contato íntimo do gel clareador com tecidos gengivais, assim, este estudo avaliou a resposta inflamatória imediata, através do teste edemogênico, induzido por gel de clareamento caseiro à base de peróxido de carbamida a 10% com diferentes agentes dessensibilizantes, a quantificação de peróxido de hidrogênio liberado e o pH dos géis branqueadores. Material e Métodos: Quarenta e oito ratos foram divididos em 4 grupos (n = 12): grupocontrole CTRL, WP-Whiteness Perfect 10% (FGM Produtos Odontológicos, Joinville, SC, Brasil), OPA-Opalescence 10% (Ultradent Products Inc., South Jordan, IT, EUA) e PB-Power Bleaching (BM4, Palhoça, SC, Brasil). Para o teste edemogênico, todos os ratos receberam uma injeção intravenosa de Evan's Blue; após 30 min, 0,2 mL de cada gel clareador foi injetado no tecido subcutâneo dos ratos, e os resultados da permeabilidade vascular foram avaliados após 3 e 6 horas. A quantidade de HP liberada e o pH de cada produto também foram determinados. Os dados foram submetidos ao teste estatístico (P <0,05). Resultados: Às 3h, o PB apresentou maior permeabilidade vascular que os demais grupos. Às 6h, o PB produziu permeabilidade vascular semelhante ao WHI e maior que os grupos OPA e CTRL. O grupo OPA apresentou maior permeabilidade vascular às 6h em relação às 3h; Não existe essa diferença em outros grupos. O grupo PB apresentou maiores concentrações de HP que os demais grupos. Conclusão: Em geral, o PB causou maior quantidade de edema inflamatório e maior quantidade de HP liberado. Estes resultados sugerem que estes géis branqueadores causam maior agressividade nos tecidos gengivais moles que eventualmente acabam em contato com produtos de branqueamento. (AU)


Asunto(s)
Animales , Ratas , Permeabilidad Capilar , Estética Dental , Peróxido de Hidrógeno , Peróxidos , Blanqueamiento de Dientes
19.
Dent. press endod ; 7(2): 67-71, May-Aug. 2017. ilus, tab
Artículo en Portugués | LILACS, BBO | ID: biblio-859403

RESUMEN

Objetivo: o objetivo desse trabalho foi estudar, in vitro, o nível de escoamento dos cimentos Endofill, AH Plus, MTA Fillapex, Sealer 26 e Pulp Canal Sealer EWT. Métodos: os cimentos foram manipulados de acordo com as recomendações dos fabricantes. A determinação do escoamento foi conseguida em conformidade com a especificação #57 da ADA (American Dental Association). Na comparação entre os grupos, foi realizada a ANOVA (análise de variância) e posterior teste de Tukey, com nível de confiança de 95%. Resultados: os resultados mostraram que o cimento MTA Fillapex apresentou o maior escoamento entre os cimentos estudados e o cimento AH Plus foi o único que apresentou escoamento estatisticamente significativo após 24 e 48 horas. Conclusão: concluiu-se que todos os cimentos avaliados estão em conformidade com a especificação #57 da ADA. No entanto, o cimento MTA Fillapex foi superior aos outros cimentos analisados, no que se refere ao poder de escoamento. O desempenho clínico do cimento obturador está diretamente relacionado à sua capacidade de penetrar nos túbulos dentinários e canais laterais; daí a importância do estudo do escoamento dos cimentos endodônticos.


Asunto(s)
Materiales Biocompatibles/uso terapéutico , Cementos Dentales/clasificación , Cementos Dentales/uso terapéutico , Endodoncia , Obturación del Conducto Radicular , Tratamiento del Conducto Radicular
20.
Rev. Assoc. Paul. Cir. Dent ; 71(1): 36-40, Jan.Fev.Mar.2017.
Artículo en Portugués | LILACS, BBO | ID: biblio-832087

RESUMEN

Este estudo teve como objetivo avaliar a acurácia de quatro localizadores apicais eletrônicos durante o retratamento endodôntico. Quarenta pré-molares unirradiculares com apenas um canal, ápice completamente formado, foram divididos em quatro grupos e analisados: Grupo 1: Root ZX ll. Grupo 2: Mini Root. Grupo 3: Propex ll e Grupo 4: Mini Apex. Todos os elementos foram padronizados no comprimento de 22 mm, instrumentados com limas Wave One Primary (25.08), obturados e armazenados. Após um mês, foram desobturados com limas reciprocantes Wave One Primary (25.08) e, em seguida, montados em blocos de esponja vegetal, embebida em solução de cloreto de sódio a 0,9%. A acurácia eletrônica de cada elemento foi realizada, utilizando-se uma lima manual do tipo K#20, até que a mesma fosse ultrapassada pelo forame e recuada até o comprimento real do dente, onde, então, as medidas de cada elemento eram anotadas. Todas as medidas obtidas de cada grupo passaram por análise estatística. Não houve diferença estatisticamente significante entre os localizadores apicais eletrônicos analisados, quando utilizados durante o retratamento endodôntico, sendo possível concluir que, os quatro modelos de localizadores apicais analisados mostraram-se eficientes durante o retratamento endodôntico, dentro dos limites estabelecidos, não havendo diferença entre eles.


This study aimed to evaluate the accuracy of four electronic apex locators during endodontic retreatment. Forty single-rooted premolars, with a root canal, with fully formed apex, were divided into four groups and analyzed: Group 1: Root ZX II. Group 2: Mini Root. Group 3: Propex II and Group 4: Mini Apex. All elements have been standardized in the length of 22 mm, instrumented with Wave One Primary (25.08) files, sealed and stored. After a month, the desobturation with reciprocating Wave One Primaty (25.08) files off and then assembled into blocks vegetable sponge, soaked in 0.9% sodium chloride solution. Electronic accuracy of each element was performed using a manual file type K#20, until it was overtaken by the foramen and retracted to the actual length of the tooth, which then measures each element were noted. All measurements obtained from each group passed by statistical analysis. There was no statistically significant difference between the electronic apex locators analyzed when used during endodontic retreatment it is possible to conclude that the four models analyzed apex locators were effective during endodontic retreatment wirhin the established timits, there is no difference between them.


Asunto(s)
Endodoncia , Retratamiento , Ápice del Diente
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA