Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 31
Filtrar
1.
J. bras. pneumol ; 49(3): e20230056, 2023. tab, graf
Artículo en Inglés | LILACS-Express | LILACS | ID: biblio-1440438

RESUMEN

ABSTRACT Objective: COVID-19 has been associated with a significant burden to those who survive the acute phase. We aimed to describe the quality of life and symptoms of anxiety, depression, and posttraumatic stress disorder (PTSD) at 90 days after hospital discharge of COVID-19 patients. Methods: Patients with COVID-19 admitted to a private hospital in the city of São Paulo, Brazil, between April of 2020 and April of 2021 were interviewed by telephone at 30 and 90 days after discharge to assess the quality of life and symptoms of depression, anxiety, and PTSD. Results: A total of 2,138 patients were included. The mean age was 58.6 ± 15.8 years, and the median length of hospital stay was 9.0 (5.0-15.8) days. Between the two time points, depression increased from 3.1% to 7.2% (p < 0.001), anxiety increased from 3.2% to 6.2% (p < 0.001), and PTSD increased from 2.3% to 5.0% (p < 0.001). At least one physical symptom related to COVID-19 diagnosis persisted in 32% of patients at day 90. Conclusions: Persistence of physical symptoms was high even at 90 days after discharge. Although the prevalence of symptoms of anxiety, depression, and PTSD was low, these symptoms persisted for three months, with a significant increase between the time points. This finding indicates the need to identify at-risk patients so that they can be given an appropriate referral at discharge.


RESUMO Objetivo: A COVID-19 tem sido associada a um fardo significativo para aqueles que sobrevivem à fase aguda. Nosso objetivo foi descrever a qualidade de vida e sintomas de ansiedade, depressão e transtorno de estresse pós-traumático (TEPT) 90 dias após a alta hospitalar em pacientes com COVID-19. Métodos: Pacientes com COVID-19 internados em um hospital privado na cidade de São Paulo (SP) entre abril de 2020 e abril de 2021 foram entrevistados por telefone 30 e 90 dias após a alta para avaliar a qualidade de vida e sintomas de depressão, ansiedade e TEPT. Resultados: Foram incluídos 2.138 pacientes. A média de idade foi de 58,6 ± 15,8 anos, e a mediana do tempo de internação hospitalar foi de 9,0 (5,0-15,8) dias. Entre os dois momentos, a depressão aumentou de 3,1% para 7,2% (p < 0,001), a ansiedade, de 3,2% para 6,2% (p < 0,001), e o TEPT, de 2,3% para 5,0% (p < 0,001). Pelo menos um sintoma físico relacionado ao diagnóstico de COVID-19 persistia em 32% dos pacientes no 90º dia. Conclusões: A persistência dos sintomas físicos foi elevada mesmo 90 dias após a alta. Embora a prevalência de sintomas de ansiedade, depressão e TEPT tenha sido baixa, esses sintomas persistiram por três meses, com aumento significativo entre os momentos. Esse achado indica a necessidade de identificar os pacientes de risco para que possam receber o encaminhamento adequado no momento da alta.

2.
Bernoche, Claudia; Timerman, Sergio; Polastri, Thatiane Facholi; Giannetti, Natali Schiavo; Siqueira, Adailson Wagner da Silva; Piscopo, Agnaldo; Soeiro, Alexandre de Matos; Reis, Amélia Gorete Afonso da Costa; Tanaka, Ana Cristina Sayuri; Thomaz, Ana Maria; Quilici, Ana Paula; Catarino, Andrei Hilário; Ribeiro, Anna Christina de Lima; Barreto, Antonio Carlos Pereira; Azevedo, Antonio Fernando Barros de Filho; Pazin, Antonio Filho; Timerman, Ari; Scarpa, Bruna Romanelli; Timerman, Bruno; Tavares, Caio de Assis Moura; Martins, Cantidio Soares Lemos; Serrano, Carlos Vicente Junior; Malaque, Ceila Maria Sant'Ana; Pisani, Cristiano Faria; Batista, Daniel Valente; Leandro, Daniela Luana Fernandes; Szpilman, David; Gonçalves, Diego Manoel; Paiva, Edison Ferreira de; Osawa, Eduardo Atsushi; Lima, Eduardo Gomes; Adam, Eduardo Leal; Peixoto, Elaine; Evaristo, Eli Faria; Azeka, Estela; Silva, Fabio Bruno da; Wen, Fan Hui; Ferreira, Fatima Gil; Lima, Felipe Gallego; Fernandes, Felipe Lourenço; Ganem, Fernando; Galas, Filomena Regina Barbosa Gomes; Tarasoutchi, Flavio; Souza, Germano Emilio Conceição; Feitosa, Gilson Soares Filho; Foronda, Gustavo; Guimarães, Helio Penna; Abud, Isabela Cristina Kirnew; Leite, Ivanhoé Stuart Lima; Linhares, Jaime Paula Pessoa Filho; Moraes, Junior João Batista de Moura Xavier; Falcão, João Luiz Alencar de Araripe; Ramires, Jose Antônio Franchini; Cavalini, José Fernando; Saraiva, José Francisco Kerr; Abrão, Karen Cristine; Pinto, Lecio Figueira; Bianchi, Leonardo Luís Torres; Lopes, Leonardo Nícolau Geisler Daud; Piegas, Leopoldo Soares; Kopel, Liliane; Godoy, Lucas Colombo; Tobase, Lucia; Hajjar, Ludhmila Abrahão; Dallan, Luís Augusto Palma; Caneo, Luiz Fernando; Cardoso, Luiz Francisco; Canesin, Manoel Fernandes; Park, Marcelo; Rabelo, Marcia Maria Noya; Malachias, Marcus Vinícius Bolívar; Gonçalves, Maria Aparecida Batistão; Almeida, Maria Fernanda Branco de; Souza, Maria Francilene Silva; Favarato, Maria Helena Sampaio; Carrion, Maria Julia Machline; Gonzalez, Maria Margarita; Bortolotto, Maria Rita de Figueiredo Lemos; Macatrão-Costa, Milena Frota; Shimoda, Mônica Satsuki; Oliveira-Junior, Mucio Tavares de; Ikari, Nana Miura; Dutra, Oscar Pereira; Berwanger, Otávio; Pinheiro, Patricia Ana Paiva Corrêa; Reis, Patrícia Feitosa Frota dos; Cellia, Pedro Henrique Moraes; Santos Filho, Raul Dias dos; Gianotto-Oliveira, Renan; Kalil Filho, Roberto; Guinsburg, Ruth; Managini, Sandrigo; Lage, Silvia Helena Gelas; Yeu, So Pei; Franchi, Sonia Meiken; Shimoda-Sakano, Tania; Accorsi, Tarso Duenhas; Leal, Tatiana de Carvalho Andreucci; Guimarães, Vanessa; Sallai, Vanessa Santos; Ávila, Walkiria Samuel; Sako, Yara Kimiko.
Arq. bras. cardiol ; 113(3): 449-663, Sept. 2019. tab, graf
Artículo en Portugués | SES-SP, LILACS, SESSP-IDPCPROD, SES-SP | ID: biblio-1038561
3.
In. Consolim-Colombo, Fernanda M; Saraiva, José Francisco Kerr; Izar, Maria Cristina de Oliveira. Tratado de Cardiologia: SOCESP / Cardiology Treaty: SOCESP. São Paulo, Manole, 4ª; 2019. p.662-665.
Monografía en Portugués | LILACS | ID: biblio-1009432
4.
Arq. bras. cardiol ; 103(5): 410-417, 11/2014. tab, graf
Artículo en Inglés | LILACS | ID: lil-730366

RESUMEN

Background: The hemodynamic effects of noninvasive ventilation with positive pressure in patients with pulmonary hypertension without left ventricular dysfunction are not clearly established. Objectives: Analyze the impact of increasing airway pressure with continuous positive airway pressure on hemodynamic parameters and, in particular, on cardiac output in patients with variable degrees of pulmonary hypertension. Methods: The study included 38 patients with pulmonary hypertension caused by mitral stenosis without left ventricular dysfunction or other significant valvulopathy. The hemodynamic state of these patients was analyzed in three conditions: baseline, after continuous positive pressure of 7 cmH2O and, finally, after pressure of 14 cmH2O. Results: The population was composed of predominantly young and female individuals with significant elevation in pulmonary arterial pressure (mean systolic pressure of 57 mmHg). Of all variables analyzed, only the right atrial pressure changed across the analyzed moments (from the baseline condition to the pressure of 14 cmH2O there was a change from 8 ± 4 mmHg to 11 ± 3 mmHg, respectively, p = 0.031). Even though there was no variation in mean cardiac output, increased values in pulmonary artery pressure were associated with increased cardiac output. There was no harmful effect or other clinical instability associated with use application of airway pressure. Conclusion: In patients with venocapillary pulmonary hypertension without left ventricular dysfunction, cardiac output response was directly associated with the degree of pulmonary hypertension. The application of noninvasive ventilation did not cause complications directly related to the ventilation systems. .


Fundamento: Os efeitos hemodinâmicos da ventilação não invasiva com pressão positiva em pacientes com hipertensão pulmonar sem disfunção ventricular esquerda não estão bem estabelecidos. Objetivos: Analisar o impacto da pressurização aérea crescente através da pressão positiva contínua das vias aéreas nos parâmetros hemodinâmicos e, principalmente, no débito cardíaco de pacientes com graus variáveis de hipertensão pulmonar. Métodos: Foram incluídos 38 pacientes com hipertensão pulmonar causada por estenose mitral sem disfunção ventricular esquerda ou outra valvopatia significativa. O estado hemodinâmico deses pacientes foi estudado em três condições: basal, após uso de pressão positiva contínua de 7 cmH2O e , finalmente, após pressão de 14 cmH2O. Resultados: A população foi composta por indivíduos predominantemente jovens, do sexo feminino e com elevação significativa da pressão arterial pulmonar (pressão sistólica média de 57 mmHg). De todas as variáveis analisadas, apenas a pressão de átrio direito apresentou variação ao longo dos momentos estudados (da condição basal para a de pressão de 14 cmH2O houve aumento de 8 ± 4 mmHg para 11 ± 3 mmHg, respectivamente, p = 0,031). Apesar de não ter havido variação do valor médio do débito cardíaco, valores mais elevados de pressões na artéria pulmonar estiveram associados ao aumento do débito cardíaco. Não houve efeito deletério ou qualquer instabilidade clínica associada ao uso da pressurização das vias aéreas. Conclusão: Em pacientes com hipertensão venocapilar pulmonar sem disfunção ventricular esquerda, a resposta ...

5.
Rev. bras. cir. cardiovasc ; 26(3): 380-385, jul.-set. 2011.
Artículo en Portugués | LILACS | ID: lil-624519

RESUMEN

INTRODUÇÃO: Os bons resultados da comissurotomia mitral a céu aberto são bem conhecidos e existe a hipótese de que se poderiam obter melhores resultados em pacientes selecionados pelo escore ecocardiográfico. OBJETIVO: Analisar os resultados tardios da comissurotomia mitral em pacientes selecionados pelo escore ecocardiográfico e identificar variáveis com influência nesses resultados. MÉTODOS: De janeiro de 1990 a agosto de 1994, 50 pacientes com estenose mitral reumática foram submetidos à comissurotomia mitral a céu aberto no Instituto do Coração do Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo. Foram incluídos pacientes com idade < 60 anos, classe funcional II, III ou IV (New York Heart Association) e escore ecocardiográfico 9. A idade média foi de 32,68 ± 8,29 anos, sendo 41 (82%) pacientes do sexo feminino. Três (6%) pacientes estavam em classe funcional II, 46 (92%) em III e um (2%) em IV. Quarenta e seis (92%) pacientes apresentavam ritmo sinusal e quatro (8%), fibrilação atrial. A área valvar mitral média foi de 0,9 ± 0,2 cm². RESULTADOS: Não houve mortalidade hospitalar. Ocorreram dois óbitos tardios, um relacionado à valvopatia. A sobrevida actuarial foi de 95,5 ± 3,1%, sobrevida livre de reoperação, 62,3 ± 11,8%, e sobrevida livre de tromboembolismo, 88,2 ± 5,0% em 18 anos. Não houve endocardite. O escore ecocardiográfico não teve influência significante em reoperações na evolução tardia. CONCLUSÃO: A comissurotomia mitral a céu aberto obteve resultados tardios excelentes nos pacientes com baixo escore ecocardiográfico.


INTRODUCTION: The good results of open mitral commissurotomy are well known and there is a hypothesis that it could provide better results in patients selected by echocardiographic score. OBJECTIVE: The purpose of this study is to analyze the late results with open mitral commissurotomy in patients selected by score and to identify variables influencing these results. METHODS: From January 1990 to August 1994, 50 patients were submitted to open mitral commissurotomy due to rheumatic mitral stenosis in Heart Institute of University of Sao Paulo Medical School. Patients with age < 60 years, in functional class II, III or IV (New York Heart Association) and echocardiographic score 9 were included. The mean age was 32.7 ± 8.3 years and 41 patients (82%) were female. The functional class was II in three patients (6%), III in 46 (92%) and IV in one (2%). Forty six patients (92%) were in sinus rhythm and four (8%) were in atrial fibrillation. The mean mitral valve area was 0.9 ± 0.2 cm². RESULTS: There was no hospital mortality. There were two late deaths, one related to valve disease. Actuarial survival was 95.5 ± 3.1 %, freedom from reoperation was 62.3 ± 11,8% and freedom from tromboembolism was 88,2 ± 5,0% in 18 years. There was no endocarditis. The grade of the echocardiographic score had no significant influence on the reoperations in late evolution. CONCLUSION: Open mitral commissurotomy presented excelent long term results in rheumatic patients with low echocardiographic score.


Asunto(s)
Adulto , Femenino , Humanos , Masculino , Persona de Mediana Edad , Adulto Joven , Estenosis de la Válvula Mitral/mortalidad , Estenosis de la Válvula Mitral/cirugía , Cardiopatía Reumática/mortalidad , Cardiopatía Reumática/cirugía , Métodos Epidemiológicos , Ecocardiografía Doppler/métodos , Estenosis de la Válvula Mitral , Válvula Mitral/cirugía , Cardiopatía Reumática , Resultado del Tratamiento
6.
Arq. bras. cardiol ; 96(3,supl.1): 1-68, 2011. ilus, tab
Artículo en Portugués | LILACS | ID: lil-588887
7.
Rev. bras. cardiol. invasiva ; 18(3): 321-326, set. 2010. tab, graf
Artículo en Portugués | LILACS | ID: lil-566809

RESUMEN

INTRODUÇÃO: A técnica de ecocardiografia tridimensional em tempo real (eco-3D) para avaliação da área valvar mitral (AVM) é uma técnica inovadora, que deve ser validada na compração com técnicas de cálculos de AVM já consagrados. O cálculo da AVM pelo método de Gorlin já foi bem estabelecido e correlaciona-se de forma adequada com a verdadeira AVM. Nosso objetivo foi comparar as medidas de AVM obtidas pelos métodos hemodinâmicos e ecocardiográfico, a partir de parâmetros hemodinâmicos invasivos (fórmula de Gorlin) e de eco-3D após valvoplastia mitral percutânea por cateter-balão (VCB). Método: Estudo prospectivo, realizado entre fevereiro de 2009 e fevereiro de 2010, em que foram selecionados 24 indivíduos (dos quais 22 mulheres, na faixa etária de 39 + ou - 12 anos) portadores de estenose mitral sintomática submetidos a VCB. Foi feita análise ecocardiográfica transtorácica bidimensonal e tridimensional antes e após VCB, em que foram aferidos a AVM (eco-3D/medida invasiva) e o gradiente...


BACKGROUND: Real time three-dimensional (3D) echocardiography (Echo) is an innovative technique to assess mitral valve area (MVA) that must be validated in comparison with established MVA calculation techniques. The calculation of valve area by Gorlin's method has been well established and correlates adequately with the true MVA. This study was aimed at comparing MVA obtained by hemodynamic and echocardiographic methods, based on invasive hemodynamic (Gorlin's formula) and 3D Echo parameters after percutaneous balloon mitral valvuloplasty (PBMV). METHODS: Prospective study carried out from February 2009 to February 2010, in 24 individuals (22 women, 39 ± 12 years) with symptomatic mitral stenosis undergoing PBMV. 2D and 3D Echo were compared before and after the PBMV, with MVA (3D Echo/invasive measurement) and mitral gradient (max/mean) measurements. RESULTS: Two patients were excluded (one because of a left atrial thrombus and another due to MVA > 1.5 cm²). Mean MVA obtained by the hemodynamic method was 1.73 cm², whereas the mean value obtained by 3D Echo was 1.72 cm². There was a significant correlation between MVA obtained by Gorlin's formula and 3D Echo pre-valvuloplasty (r: 0.7638; P < 0.001) and post-valvuloplasty (r: 0.6659; P < 0.0019). CONCLUSIONS: 3D Echo is an adequate method for the assessment and calculation of MVA before and after PBMV procedures providing accurate values when compared to the established MVA calculation obtained by Gorlin's formula.


Asunto(s)
Humanos , Femenino , Cateterismo , Ecocardiografía Tridimensional/métodos , Ecocardiografía Tridimensional , Ecocardiografía/métodos , Ecocardiografía , Estenosis de la Válvula Mitral/complicaciones , Estenosis de la Válvula Mitral/diagnóstico
8.
Arq. bras. cardiol ; 94(3): 406-413, mar. 2010. tab, ilus
Artículo en Portugués | LILACS | ID: lil-545830

RESUMEN

FUNDAMENTO: A análise dos resultados imediatos e a longo prazo da valvoplastia mitral por catéter-balão (VMCB) ainda são escassos na literatura, principalmente no contexto nacional. OBJETIVO: Avaliar os resultados imediatos e tardios dos pacientes submetidos à VMCB. MÉTODO: 330 pacientes consecutivos foram seguidos por 47 ± 36 meses (até 126 meses). Análises univariadas e multivariadas avaliaram os fatores relacionados ao sucesso do procedimento, à reestenose e aos eventos tardios (morte ou necessidade de nova intervenção na valva mitral). O método de Kaplan-Meier estimou a sobrevida livre de eventos. RESULTADOS: Houve sucesso do procedimento em 305 (92,4 por cento). A anatomia valvar mitral foi o principal preditor de sucesso imediato do procedimento. Durante o seguimento, a reestenose ocorreu em 77 (23,3 por cento) pacientes e esteve associada a menor área valvar mitral e maior calcificação antes do procedimento. Ocorreram 67 eventos em um tempo médio de seguimento de 38 ± 26 meses. A probabilidade de sobrevida livre de eventos foi de 95 por cento em 1 ano, 75 por cento aos 5 anos e 61 por cento aos 10 anos. Os preditores de sobrevida livre de eventos foram: idade, escore ecocardiográfico e resultado imediato do procedimento. CONCLUSÃO: A VMCB é um procedimento efetivo, sendo que mais de 60 por cento dos pacientes estiveram livres de eventos ao final do seguimento. A condição anatômica da valva mitral e a idade do paciente foram os melhores preditores da sobrevida livre de eventos e devem ser levados em consideração na seleção dos pacientes para VMCB.


BACKGROUND: The analysis of immediate and long-term results of mitral valvoplasty by balloon catheter (MVRBC) are still lacking in literature, mainly in the national context. OBJECTIVE: To assess the immediate and late results of patients submitted to mitral valve repair by balloon catheter. METHOD: A total of 330 consecutive patients were followed-up by 47 ± 36 months (up to 126 months). Univariate and multivariate analyses assessed the factors associated with the success of the procedure, restenosis and late events (death or necessity of new intervention on mitral valve). Kaplan-Meier method estimated survival without events. RESULTS: The procedure was successful in 305 cases (92.4 percent). The mitral valve anatomy was the main predictor for immediate success for the procedure. During the procedure, restenosis occurred in 77 (23.3 percent) patients and was associated with smaller mitral valve area and with larger calcification before the process. In a mean period of 38 ± 26-month follow-up, 67 events occurred. The probability of survival without events was of 95 percent in one year, 75 percent in five years and 61 percent in ten years. The predictors of survival without events were: age, echocardiography score and immediate result of the procedure. CONCLUSION: Mitral valve repair by balloon catheter is an effective procedure, as 60 percent patients did not present events after the follow-up. The anatomical condition of the mitral valve and the patient's age were the best predictors of survival without events, and should be taken into account when selecting patients for the mentioned procedure. (Arq Bras Cardiol 2010; 94(3):383-390)


Asunto(s)
Femenino , Humanos , Masculino , Cateterismo , Estenosis de la Válvula Mitral/terapia , Reestenosis Coronaria/etiología , Métodos Epidemiológicos , Estenosis de la Válvula Mitral , Resultado del Tratamiento
9.
Rev. Soc. Cardiol. Estado de Säo Paulo ; 19(2): 260-264, abr.-jun. 2009. ilus
Artículo en Portugués | LILACS | ID: lil-525971

RESUMEN

Desde os estudos iniciais de Hales, no século 18, passando pelos conceitos desenvolvidos por Guyton, na década de 70, o conhecimento da fisiologia cardiovascular possibilitou a avaliação sensível do status volêmico em pacientes críticos. A partir das medidas de pressão venosa central e de pressão capilar pulmonar, incorporando conceitos de interdependência ventricular, hoje é possível mensurar a resposta à sobrecarga de volume em pacientes sedados e sob ventilação mecânica, de forma a ajustar e evitar a hipervolemia, deletéria nessas condições. Para esse objetivo, podemos utilizar a variação da pressão de pulso, a variação da amplitude da curva de pressão venosa central e, mais recentemente, a variação do diâmetro da veia cava inferior, analisada ecocardiograficamente. Esses conhecimentos também se aplicam aos pacientes sob ventilação mecânica em uso de pressão positiva expiratória final positiva, assim como contribuem para o manejo do desmame da ventilação mecânica em pacientes com isquemia miocárdica, predispostos a desmame difícil.


Asunto(s)
Humanos , Presión Venosa Central , Respiración Artificial/métodos , Respiración Artificial , Vena Cava Inferior
11.
Arq. bras. cardiol ; 90(6): 433-440, jun. 2008. graf, tab
Artículo en Inglés, Portugués | LILACS | ID: lil-485189

RESUMEN

FUNDAMENTO: Estudos nacionais em insuficiência cardíaca descompensada (ICD) são fundamentais para o entendimento dessa afecção em nosso meio. OBJETIVO: Determinar as características dos pacientes com ICD em uma unidade de emergência. MÉTODOS: Examinamos prospectivamente 212 pacientes com o diagnóstico de insuficiência cardíaca descompensada, os quais foram admitidos em uma unidade de emergência (UE) de hospital especializado em cardiologia. Estudaram-se variáveis clínicas, apresentação e causas de descompensação. Em 100 pacientes, foram analisados exames complementares, prescrição de drogas vasoativas, tempo de internação e letalidade. RESULTADOS: Entre os pesquisados houve predomínio de homens (56 por cento) e a etiologia isquêmica foi a mais freqüente (29,7 por cento), apesar da elevada freqüência de valvares (15 por cento) e chagásicos (14,7 por cento). A forma de apresentação e a causa de descompensação mais comuns foram, respectivamente, congestão (80,7 por cento) e má adesão/medicação inadequada (43,4 por cento). Na subanálise dos 100 pacientes, a disfunção sistólica foi a mais freqüente (55 por cento), uso de drogas vasoativas ocorreu em 20 por cento e a letalidade foi de 10 por cento. Análise comparativa entre os pacientes que receberam alta e faleceram durante a internação ratificou alguns critérios de mau prognóstico: pressão arterial sistólica reduzida, baixo débito associado à congestão, necessidade de droga vasoativa, fração de ejeção do ventrículo esquerdo reduzida, diâmetro diastólico do ventrículo esquerdo (DDVE) aumentado e hiponatremia. CONCLUSÃO: Este trabalho apresenta dados sobre o perfil da população com insuficiência cardíaca descompensada atendida na unidade de emergência de um hospital especializado em cardiologia da região sudeste do Brasil. Na avaliação inicial destes pacientes dados clínico-hemodinâmicos e de exames complementares fornecem subsídios para estratificação de risco, auxiliando na decisão de internação...


BACKGROUND: National studies on decompensated heart failure (DHF) are key to the understanding of this condition in our midst. OBJECTIVE: To determine the characteristics of DHF patients in an emergency department. METHODS: A total of 212 patients diagnosed with decompensated heart failure who had been admitted to an emergency department (EU) of a cardiology hospital were prospectively evaluated. Clinical variables, form of presentation and causes of decompensation were studied. In 100 patients, ancillary tests, prescription of vasoactive drugs, length of hospital stay and mortality were also analyzed. RESULTS: There was a predominance of the male gender (56 percent) and the most frequent etiology was ischemia (29,7 percent) despite high frequency of valvular (15 percent) and chagasic (14,7 percent) etiologies. The most common form of presentation and cause of decompensation were congestion (80.7 percent) and poor compliance/inadequate medication (43.4 percent), respectively. In the subanalysis of the 100 patients, systolic dysfunction was the most common cause of decompensation (55 percent); use of vasoactive drugs occurred in 20 percent, and mortality was 10 percent. The comparative analysis between the patients who were discharged and those who died during hospitalization confirmed some criteria of poor prognosis: reduced systolic blood pressure, low cardiac output associated with congestion, need for vasoactive drugs, reduced left ventricular ejection fraction, increased left ventricular diastolic diameter (LVDD) and hyponatremia. CONCLUSION: This study presents information about the profile of decompensated heart failure patients attended on the emergency unit of a brazilian southeast cardiology hospital. Clinical, hemodynamical and ancillary data may provide information for risk assessment in the initial evaluation helping the decision on hospitalization and advanced strategic therapies.


Asunto(s)
Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Niño , Preescolar , Femenino , Humanos , Lactante , Recién Nacido , Masculino , Persona de Mediana Edad , Adulto Joven , Presión Sanguínea/fisiología , Hospitalización , Insuficiencia Cardíaca/etiología , Brasil/epidemiología , Cardiotónicos/uso terapéutico , Dobutamina/uso terapéutico , Dopamina/uso terapéutico , Métodos Epidemiológicos , Servicio de Urgencia en Hospital/estadística & datos numéricos , Insuficiencia Cardíaca/tratamiento farmacológico , Insuficiencia Cardíaca/mortalidad , Tiempo de Internación , Adulto Joven
13.
Arq. bras. cardiol ; 83(3): 243-252, set. 2004. ilus, tab, graf
Artículo en Inglés, Portugués | LILACS | ID: lil-382726

RESUMEN

OBJETIVO: Comparar dados clínicos-laboratoriais em portadores de estenose mitral submetidos à comissurotomia ou valvoplastia por cateter-balão, obtidos ao longo de 5 anos de acompanhamento. MÉTODOS: Foram acompanhados, prospectivamente, 81 pacientes no pré (PRÉ), imediatamente após o procedimento (POI), e ao longo de cinco anos (PO12M, PO24M,..., PO60M) e randomizados em dois grupos: GC: 37 pacientes (32,4 ± 7,2 anos e 89,2 por cento mulheres) e GV: 44 pacientes (32,9 ± 9,5 anos e 90,9 por cento mulheres). A avaliação compreendeu: classe funcional, ocorrência de eventos, eletrocardiograma e ecodopplercardiograma. RESULTADOS: Houve melhora expressiva da classe funcional na maioria dos pacientes, três casos do GC e do GV estavam em classe funcional III no PO60M. Não houve diferença em relação ao gradiente mitral entre os grupos. Houve diferença das médias de área valvar mitral entre os grupos durante toda avaliação. Não ocorreram óbitos. No POI do GC observamos 3 casos com insuficiência mitral (IM) moderada, 3 com sangramento (1 reoperado) e, no GV, 4 casos com IM moderada, 1 com IM importante, 2 com tamponamento cardíaco, 1 caso necessitou cirurgia por IM importante. Ao longo de 60 meses, no GV, 9 casos evoluiram com IM moderada ou importante e no GC, 6 casos evoluiram com IM moderada ou importante e outros dois necessitaram cirurgia por dupla disfunção mitral. CONCLUSAO: Ambos os métodos obtiveram 100 por cento de sucesso com baixa taxa de complicações. No seguimento, houve elevação discreta do gradiente mitral e queda de área valvar mitral em ambos os grupos.


Asunto(s)
Humanos , Masculino , Femenino , Adulto , Persona de Mediana Edad , Estenosis de la Válvula Mitral/terapia , Distribución de Chi-Cuadrado , Ecocardiografía Doppler , Estudios de Seguimiento , Estenosis de la Válvula Mitral/cirugía , Estenosis de la Válvula Mitral , Estudios Prospectivos
15.
Arq. bras. cardiol ; 70(6): 415-421, Jun. 1998.
Artículo en Portugués | LILACS | ID: lil-320311

RESUMEN

PURPOSE: To compare immediate and late (12 months) follow-up of clinical and Doppler echocardiographic results between percutaneous mitral balloon valvuloplasty and open commissurotomy in a prospective and randomized trial. METHODS: Eighty eight symptomatic patients with severe mitral stenosis and favorable anatomy were randomized in a prospective trial comparing the two procedures. All patients were submitted to clinical and Doppler echocardiographic evaluation before the procedures and immediate and twelve months thereafter. RESULTS: Mean mitral gradient (mmHg) decreased from 12.2 +/- 5.8 to 5.80 +/- 2.7 (p < 0.001) in commissurotomy group (CG) and from 11.7 +/- 6.1 to 5.0 +/- 2.4 (p < 0.001) in the balloon valvuloplasty group (VG). Mitral valve are (cm2) increased from 0.98 +/- 0.21 to 2.52 +/- 0.46 in CG and from 1.05 +/- 0.25 to 2.18 +/- 0.40 in VG (p < 0.001). In both groups there was a slight decrease in mitral valve area at 12 month follow-up. There was no death in either group. One patient in the VG had moderate mitral regurgitation and underwent surgery. At the 12 month follow-up, all patients in CG and 97.7of patients in VG were in New York Heart Association functional class I or II. CONCLUSION: Both procedures were safe and showed similar immediate improvement in mitral gradient and functional class. Mitral valve area had a greater increase immediately after commissurotomy, however, there was a significantly greater reduction in the CG after 12 months of follow-up, when compared to balloon valvuloplasty. In both groups, mitral gradient remained reduced and most patients did not change functional class during the follow-up.


Asunto(s)
Humanos , Masculino , Femenino , Adolescente , Adulto , Persona de Mediana Edad , Procedimientos Quirúrgicos Cardíacos , Cateterismo , Estenosis de la Válvula Mitral , Ecocardiografía Doppler , Estenosis de la Válvula Mitral
18.
Arq. bras. cardiol ; 66(4): 213-216, Abr. 1996. tab, ilus
Artículo en Portugués | LILACS | ID: lil-319291

RESUMEN

PURPOSE: To compare early and 12 months results of mitral stenosis (MS) correction by percutaneous balloon valvuloplasty (PMBV) using Inoue's single-balloon or double balloon techniques. METHODS: We submitted 139 consecutive patients to PMBV using Inoue single-balloon (n = 56, GI) or the double balloon technique (n = 83, GII). The two groups were similar, in: age, sex, functional class (FC), echocardiographic (ECHO) score, mitral valve area (MVA), and gradient (G) or presence of regurgitation. Clinical and ECHO data were compared before (PRE), immediately after (POI) and one year following the procedure (PO12M). RESULTS: PMBV was successfully performed in 53 (95) patients of GI and in 79 (96) of GII. Statistical analyses showed that the groups were similar at POI but different at PO12M (p < 0.002). ECHO immediately after PMBV showed that: MVA increased from 0.99 +/- 0.23 to 2.01 +/- 0.44cm2 (p < 0.001) in GI and from 0.94 +/- 0.23 to 2.09 +/- 0.35cm2 (p < 0.001) in GII and G decreased from 11.58 +/- 5.02 to 5.16 +/- 2.23mmHg (p < 0.001) in GI and from 12.48 +/- 4.89 to 5.96 +/- 3.21mmHg (p < 0.001) in GII. After one year 36 (64) patients in GI and 62 (74) in GII underwent an ECHO study. A comparison between immediate and one year follow-up results showed that MVA decreased from 2.01 +/- 0.4 to 2.00 +/- 0.3cm2 (NS) in GI and from 2.09 +/- 0.3 to 1.74 +/- 0.4cm2 (p < 0.001) in GII and G decreased from 5.16 +/- 2.2 to 5.50 +/- 2.9mmHg (NS) in GI and from 5.96 +/- 3.2 to 8.61 +/- 4.8mmHg (p < 0.001) in GII. There was therefore a sustained improvement of MVA and G after one year in GI and a significant decrease in MVA and G in GII. The FC after one year was similar and satisfactory in both groups. CONCLUSION: Both techniques are equally effective in relieving MS immediately after PMBV, but after one year, despite similar FC, Inoue-balloon technique seems to be superior to maintain MVA and G.


Objetivo - Comparar os resultados imediatos e de 12 meses das técnicas de duplo balão e do balão único de Inoue na correção da estenose mitral (EM) pela valvoplastia por cateter-balão (VMCB). Métodos - Submetemos 139 pacientes consecutivos, portadores de EM sintomática à VMCB. A técnica de Inoue foi utilizada em 56 pacientes (GI) e a do duplo balão em 83 (GII). Ambos os grupos eram semelhantes quanto a: idade, sexo, classe funcional (CF), escore ecocardiográfico, gradiente (G) e área valvar mitral (AVM), mitral (G) e pre sença de insuficiência mitral pela ecodopplercardiografia no pré-VMCB (PRE). Analisaram-se dados clínicoecocardiográficos, no PRE, logo após-VMCB (POI) e em 12 meses (PO12M). Resultados - A VMCB foi considerada com sucesso em 53 (95%) pacientes do GI e em 79 (96%) do GII. Análise estatística revelou que os grupos eram semelhantes no POI e diferentes no PO12M (p< 0,002). Os resultados no POI mostraram que a média da AVM (cm2) aumentou de 0,99 ± 0,23 para 2,01 ± 0,44 (p< 0,001) no GI e de 0,94 ± 0,23 para 2,09 ± 0,35 (p<0,001) no GII, o G (mmHg) diminuiu de 11,58 ± 5,02 para 5,16 ± 2,23 (p<0,001) no GI e de 12,48 ± 4,89 para 5,96 ± 3,21 (p<0,001) no GII. No PO12M, 36/53 (64%) pacientes no GI e 62/79 (74%) no GII realizaram acompanhamento clínico-ecocardiográfico. A comparação entre POI e PO12M mostrou: a) AVM de 2,01 ± 0,4 x 2,00 ± 0,3 (NS) no GI e de 2,09 ± 0,3 x 1,74 ± 0,4 no GII (p<0,001); b) G de 5,16 ± 2,2 x 5,50 ± 2,9 (NS) no GI e de 5,96 ± 3,2 x 8,61 ± 4,8 (p<0,001) no GII; c) no GI, dos 4 (11%) pacientes que estavam em CF II e 32 (89%) em CF III/IV no PRE, todos evoluíram para CF I/II no POI e permaneceram nesta CF no PO12M, de forma similar no GII, dos 12 (19%) pacientes que estavam em CF II e 50 (81%) em CF III/IV no PRE, todos menos um evoluíram para CF I/II no POI e permaneceram nesta CF no PO12M. Conclusão - As duas técnicas são igualmente efetivas no POI, todavia no PO12M, a técnica de Inoue mostrou-se superior na manutenção de AVM e G


Asunto(s)
Humanos , Masculino , Femenino , Adolescente , Adulto , Persona de Mediana Edad , Cateterismo , Estenosis de la Válvula Mitral , Ecocardiografía , Estudios Prospectivos , Estudios de Seguimiento , Resultado del Tratamiento
19.
In. Sociedade de Cardiologia do Estado de Säo Paulo. SOCESP: cardiologia. Rio de Janeiro, Atheneu, 1996. p.651-9, tab, graf, ilus.
Monografía en Portugués | LILACS | ID: lil-264027
20.
Arq. bras. cardiol ; 64(5): 455-458, Mai. 1995.
Artículo en Portugués | LILACS | ID: lil-319717

RESUMEN

PURPOSE--To study characteristics of the natural history of mitral stenosis (MS) in patients that have no correlation between mitral valve areas (MVA) and symptoms. METHODS--We studied 18 patients with MS, that presented no correlation between MVA and functional class (FC), 16 (89) were female and two (11) men, with age ranging from 16 to 54 (mean 33) years. Patients assigned to group A (8 cases) had FC III and MVA > or = 1.5 cm2 and group B (10 cases) FC I/II and MVA < 1.1 cm2. FC and MVA at the start (initial time-It) and after 12 months or before surgical correction (SC) or percutaneous mitral balloon valvuloplasty (PBV) (final time-Ft) were compared. All patients with predict O2 uptake (PRED VO2) at It were evaluated. RESULTS--Five (63) patients of group A, that maintained MVA > or = 1.5 cm2, changed to FC I/II but three (38) needed a SC or PBV (2 with lesser MVA at Ft). At group B, six (60) patients needed SC or PBV. CONCLUSION--MS patients with MVA > or = 1.5 and FC III, providing MVA do not decrease, improves their FC, becoming it more compatible with MVA PRED VO2. The cases of group B presented the greatest probability of needing SC or PVB.


Asunto(s)
Humanos , Masculino , Femenino , Adolescente , Adulto , Persona de Mediana Edad , Estenosis de la Válvula Mitral , Cateterismo , Capacidad Residual Funcional , Electrocardiografía , Estenosis de la Válvula Mitral , Pronóstico
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA