Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Braz. j. med. biol. res ; 55: e12118, 2022. tab, graf
Artículo en Inglés | LILACS-Express | LILACS | ID: biblio-1384139

RESUMEN

The goal of the present study was to compare pulmonary function test (PFT) and cardiopulmonary exercise test (CPET) performance in COVID-19 survivors with a control group (CG). This was a cross-sectional study. Patients diagnosed with COVID-19, without severe signs and symptoms, were evaluated one month after the infection. Healthy volunteers matched for sex and age constituted the control group. All volunteers underwent the following assessments: i) clinical evaluation, ii) PTF; and iii) CPET on a cycle ergometer. Metabolic variables were measured by the CareFusion Oxycon Mobile device. In addition, heart rate responses, peak systolic and diastolic blood pressure, and perceived exertion were recorded. Twenty-nine patients with COVID-19 and 18 healthy control subjects were evaluated. Surviving patients of COVID-19 had a mean age of 40 years and had higher body mass index and persistent symptoms compared to the CG (P<0.05), but patients with COVID-19 had more comorbidities, number of medications, and greater impairment of lung function (P<0.05). Regarding CPET, patients surviving COVID-19 had reduced peak workload, oxygen uptake (V̇O2), carbon dioxide output (V̇CO2), circulatory power (CP), and end-tidal pressure for carbon dioxide (PETCO2) (P<0.05). Additionally, survivors had depressed chronotropic and ventilatory responses, low peak oxygen saturation, and greater muscle fatigue (P<0.05) compared to CG. Despite not showing signs and symptoms of severe disease during infection, adult survivors had losses of lung function and cardiorespiratory capacity one month after recovery from COVID-19. In addition, cardiovascular, ventilatory, and lower limb fatigue responses were the main exercise limitations.

2.
Braz. j. med. biol. res ; 54(10): e10514, 2021. tab, graf
Artículo en Inglés | LILACS | ID: biblio-1285648

RESUMEN

Exercise intolerance is the hallmark consequence of advanced chronic heart failure (HF). The six-minute step test (6MST) has been considered an option for the six-minute walk test because it is safe, inexpensive, and can be applied in small places. However, its reliability and concurrent validity has still not been investigated in participants with HF with reduced ejection fraction (HFrEF). Clinically stable HFrEF participants were included. Reliability and error measurement were calculated by comparing the first with the second 6MST result. Forty-eight hours after participants underwent the 6MST, they were invited to perform a cardiopulmonary exercise test (CPET) on a cycle ergometer. Concurrent validity was assessed by correlation between number of steps and peak oxygen uptake (V̇O2 peak) at CPET. Twenty-seven participants with HFrEF (60±8 years old and left ventricle ejection fraction of 41±6%) undertook a mean of 94±30 steps in the 6MST. Intra-rater reliability was excellent for 6MST (ICC=0.9), with mean error of 4.85 steps and superior and inferior limits of agreement of 30.6 and -20.9 steps, respectively. In addition, strong correlations between number of steps and CPET workload (r=0.76, P<0.01) and peak V̇O2 (r=0.71, P<0.01) were observed. From simple linear regression the following predictive equations were obtained with 6MST results: V̇O2 peak (mL/min) = 350.22 + (7.333 × number of steps), with R2=0.51, and peak workload (W) = 4.044 + (0.772 × number of steps), with R2=0.58. The 6MST was a reliable and valid tool to assess functional capacity in HFrEF participants and may moderately predict peak workload and oxygen uptake of a CPET.


Asunto(s)
Humanos , Persona de Mediana Edad , Anciano , Prueba de Esfuerzo , Insuficiencia Cardíaca/diagnóstico , Consumo de Oxígeno , Volumen Sistólico , Reproducibilidad de los Resultados , Tolerancia al Ejercicio , Prueba de Paso
3.
Braz. j. med. biol. res ; 54(11): e10974, 2021. tab, graf
Artículo en Inglés | LILACS | ID: biblio-1285663

RESUMEN

Continuous positive airway pressure (CPAP) has been used to improve gas exchange and diaphragmatic function, among others benefits. Moreover, it can be used to increase exercise tolerance and positively influence ventilatory function and breathing pattern (BP) during exercise. However, there is no information about the long-term effects of CPAP, as an adjunct to an inpatient cardiac rehabilitation (CR) program, on BP and heart rate variability (HRV) of patients after coronary artery bypass grafting surgery (CABG). Twenty patients were allocated to receive, after randomization, standard inpatient CR without CPAP (control group - CG) or CR with CPAP between 10 to 12 cmH2O (CPAP group - CPG) associated with the exercises. Participants were assessed preoperatively and on the discharge day, in the sitting rest position. Outcome measurements included BP variables, collected by respiratory inductive plethysmography, and HRV, collected by polar precision performance. The CPG presented lower values of percent rib cage inspiratory and expiratory contributions to tidal volume (%RCi and %RCe) at discharge time, compared to CG. No statistical differences between groups were observed for HRV variables and both groups presented lower values of these indices, compared to preoperative ones. In this context, the patients who received CPAP throughout the whole rehabilitation program were discharged with a better BP, which could indicate more synchronized breathing. CPAP did not influence cardiac autonomic modulation in the long term.


Asunto(s)
Ejercicio Físico , Presión de las Vías Aéreas Positiva Contínua , Respiración , Puente de Arteria Coronaria , Frecuencia Cardíaca
4.
Braz. j. med. biol. res ; 54(2): e10084, 2021. tab, graf
Artículo en Inglés | LILACS, ColecionaSUS | ID: biblio-1142577

RESUMEN

The objective of this study was to investigate the impact of chronic obstructive pulmonary disease (COPD)-heart failure (HF) coexistence on linear and nonlinear dynamics of heart rate variability (HRV). Forty-one patients (14 with COPD-HF and 27 HF) were enrolled and underwent pulmonary function and echocardiography evaluation to confirm the clinical diagnosis. Heart rate (HR) and R-R intervals (iRR) were collected during active postural maneuver (APM) [supine (10 min) to orthostasis (10 min)], respiratory sinus arrhythmia maneuver (RSA-M) (4 min), and analysis of frequency domain, time domain, and nonlinear HRV. We found expected autonomic response during orthostatic changes with reduction of mean iRR, root mean square of successive differences between heart beats (RMSSD), RR tri index, and high-frequency [HF (nu)] and an increased mean HR, low-frequency [LF (nu)], and LF/HF (nu) compared with supine only in HF patients (P<0.05). Patients with COPD-HF coexistence did not respond to postural change. In addition, in the orthostatic position, higher HF nu and lower LF nu and LF/HF (nu) were observed in COPD-HF compared with HF patients. HF patients showed an opposite response during RSA-M, with increased sympathetic modulation (LF nu) and reduced parasympathetic modulation (HF nu) (P<0.05) compared with COPD-HF patients. COPD-HF directly influenced cardiac autonomic modulation during active postural change and controlled breathing, demonstrating an autonomic imbalance during sympathetic and parasympathetic maneuvers compared with isolated HF.


Asunto(s)
Humanos , Masculino , Femenino , Persona de Mediana Edad , Anciano , Enfermedad Pulmonar Obstructiva Crónica/complicaciones , Insuficiencia Cardíaca/complicaciones , Frecuencia Cardíaca , Volumen Sistólico , Función Ventricular Izquierda , Dinámicas no Lineales
5.
Braz. j. med. biol. res ; 51(11): e7837, 2018. tab, graf
Artículo en Inglés | LILACS | ID: biblio-974248

RESUMEN

The objective of this study was to assess cardiovascular, respiratory, and metabolic responses during a commonly used dynamic leg press resistance exercise until exhaustion (TEx) at different intensities and compare with critical load (CL). This was a prospective, cross-sectional, controlled, and crossover study. Twelve healthy young men (23±2.5 years old) participated. The subjects carried out three bouts of resistance exercise in different percentages of 1 repetition maximum (60, 75, and 90% 1RM) until TEx. CL was obtained by means of hyperbolic model and linearization of the load-duration function. During all bout intensities, oxygen uptake (VO2), carbon dioxide production (VCO2), ventilation (VE), and respiratory exchange ratio (RER) were obtained. Variations (peak-rest=Δ) were corrected by TEx. In addition, systolic and diastolic blood pressure (SBP and DBP), blood lactate concentration [La-] and Borg scores were obtained at the peak and corrected to TEx. CL induced greater TEx as well as number of repetitions when compared to all intensities (P<0.001). During CL, Borg/TEx, ΔSBP/TEx, ΔDBP/TEx, and [La-] were significantly lower compared with 90% load (P<0.0001). In addition, VO2, VCO2, VE, and RER were higher during CL when compared to 90 or 75%. TEx was significantly correlated with VO2 on CL (r=0.73, P<0.05). These findings support the theory that CL constitutes the intensity that can be maintained for a very long time, provoking greater metabolic and ventilatory demand and lower cardiovascular and fatigue symptoms during resistance exercise.


Asunto(s)
Humanos , Masculino , Adulto , Consumo de Oxígeno/fisiología , Intercambio Gaseoso Pulmonar/fisiología , Prueba de Esfuerzo/métodos , Entrenamiento de Fuerza , Fatiga/fisiopatología , Frecuencia Cardíaca/fisiología , Factores de Tiempo , Estudios Transversales , Estudios Prospectivos , Estudios Cruzados
6.
Rio de Janeiro; Centro Brasileiro de Pesquisas Físicas; maio 1997. 461 p. ilus.(Ciência e Sociedade).
Monografía en Portugués | LILACS | ID: lil-355830
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA