Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Añadir filtros








Intervalo de año
1.
Rev. bras. cir. cardiovasc ; 35(4): 477-483, July-Aug. 2020. tab, graf
Artículo en Inglés | LILACS, SES-SP | ID: biblio-1137312

RESUMEN

Abstract Objective: Left ventricular assist device (LVAD) implantation with concomitant Dor plasty is only reported anecdotally. We herein aimed to describe our experience with LVAD and concomitant Dor procedures and describe long-term outcomes of this special subset of heart failure patients. Methods: Between January/2010 and December/2018, 144 patients received LVAD therapy at our institution. Of those, five patients (80% male, 60.4±7.2 years) presented with an apical aneurysm and received concomitant Dor plasty. Apical aneurysms presented diameter between 75 and 98 mm, with one impending rupture. Results: Procedural success was achieved in all patients. No unplanned right ventricular assist device implantation occurred. Furthermore, no acute 30-day mortality was seen. In follow-up, one patient was lost due to intentional disconnection of the driveline. One patient underwent heart transplantation on postoperative day 630. The remaining three patients are still on device with sufficient flow; pump thromboses were successfully managed by lysis therapy in one patient. Conclusion: LVAD implantation with concomitant Dor procedure is feasible, safe, and occasionally performed in patients with ischemic cardiomyopathy. Major advantages are prevention of thromboembolism and facilitation of LVAD placement by improving pump stability and warranting midventricular, coaxial alignment of the inflow cannula. In long-term follow-up, no adverse event associated with Dor plasty was observed.


Asunto(s)
Humanos , Masculino , Femenino , Persona de Mediana Edad , Anciano , Corazón Auxiliar , Tromboembolia , Estudios Retrospectivos , Trasplante de Corazón , Intervención Coronaria Percutánea , Insuficiencia Cardíaca/cirugía
2.
Rev. bras. cir. cardiovasc ; 34(3): 368-371, Jun. 2019. tab, graf
Artículo en Inglés | LILACS | ID: biblio-1013464

RESUMEN

Abstract The Bridge Occlusion Balloon is a compliant balloon, specifically designed for temporary Superior vena cava occlusion in case of Superior Vena Cava laceration during lead extraction procedures. We here report the first case, using Bridge Occlusion Ballon for a venous angioplasty in a patient with dysfunctional pacemaker leads and symptomatic Superior Vena Cava occlusion. After successful lead extraction, venography was showing a narrow venous canal. Therefore, venous angioplasty using the Bridge balloon was performed. Especially for high-risk lead extraction cases in patients with Superior Vena Cava stenosis, the Bridge Occlusion Ballon might be used as a combination of a safety-net in case of Superior Vena Cava perforation and for Superior Vena Cava angioplasty.


Asunto(s)
Humanos , Masculino , Anciano de 80 o más Años , Síndrome de la Vena Cava Superior/terapia , Angioplastia de Balón Asistida por Láser/métodos , Síndrome de la Vena Cava Superior/diagnóstico por imagen , Flebografía/métodos , Factores de Riesgo , Resultado del Tratamiento , Angiografía por Tomografía Computarizada/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA