Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Añadir filtros








Intervalo de año
1.
J. bras. nefrol ; 19(4): 376-380, dez. 1997. ilus, tab
Artículo en Portugués | LILACS | ID: lil-209852

RESUMEN

O objetivo deste trabalho é avaliar o papel do eco-Doppler colorido (EDC) no diagnóstico da hipertensäo renovascular, comparado à arteriografia. Foram estudadas 45 artérias renais de 23 pacientes, sendo 36 artérias com laudos concordantes (92,3 por cento), 3 discordantes (7,7 por cento) e 6 inconclusivos (13,4 por cento). Os valores de sensibilidade, especificidade, valor preditivo positivo e valor preditivo negativo do EDC foram de 95,6 por cento, 87,5 por cento, 91,6 por cento e 93,3 por cento respectivamente. Os autores concluem que o EDC pode ser utilizado rotineiramente na investigaçäo de pacientes com suspeita de hipertensäo renovascular.


Asunto(s)
Humanos , Masculino , Femenino , Adolescente , Adulto , Persona de Mediana Edad , Arteria Renal/patología , Ecocardiografía Doppler en Color , Hipertensión Renovascular , Arteria Renal , Arteria Renal , Angiografía , Valor Predictivo de las Pruebas , Estudios Prospectivos , Sensibilidad y Especificidad , Hipertensión Renovascular
2.
Arq. bras. cardiol ; 68(6): 429-431, Jun. 1997. ilus
Artículo en Portugués | LILACS | ID: lil-320325

RESUMEN

PURPOSE: To evaluate the efficiency of a non-surgical treatment of the femoral false aneurysm following cardiac catheterization using the color Doppler echocardiography monitorization. METHODS: From August 1993 to October 1996, 17 patients were evaluated by the color Doppler echocardiography, 7 women and 10 men, between 58 and 77 years of age, with the diagnosis of femoral false aneurysms after cardiac catheterization. All the cases were selected for therapy with this new technique, that consisted of the compression of the false aneurysm with the transducer of the ultrasound device and monitorization of the evolution of the false aneurysm thrombosis, through image observation in real time, on the equipment monitor. RESULTS: There were 17 selected patients, 16 were successfully treated, requiring an average of 30 minutes of compression with consequent thrombosis of the false aneurysm, without recurrence in 30 days of follow-up. No complications with the use of this technique were noted and the hospitalization period was, on average, 1 day. CONCLUSION: This technique is efficient, safe and should be the first choice for the therapy of patients with femoral aneurysm following cardiac catheterization.


Asunto(s)
Humanos , Masculino , Femenino , Persona de Mediana Edad , Aneurisma Falso , Arteria Femoral , Cateterismo Cardíaco/efectos adversos , Estudios Prospectivos , Aneurisma Falso , Ecocardiografía Doppler en Color , Arteria Femoral , Constricción
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA