Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Añadir filtros








Intervalo de año
1.
Chinese Journal of Medical Instrumentation ; (6): 183-187, 2021.
Artículo en Chino | WPRIM | ID: wpr-880448

RESUMEN

Biliary stent has been widely used in the treatment of biliary stricture and obstruction, it can relieve the pain of patients effectively, but bacterial infection and stent obstruction are still troublesome after surgery. We introduce the mechanism of infection and stent blockage caused by bacterial invasion after biliary stent implantation, and expound the formation mechanism of bacterial biofilm and bile sludge in this review. Antibacterial biliary stent is an effective way to inhibit biliary tract infection, the literatures on antibacterial modification of biliary stent with different antibacterial methods in domestic and abroad are reviewed, and the research prospect of antibacterial biliary stent is summarized and prospected.


Asunto(s)
Humanos , Antibacterianos/farmacología , Bilis , Sistema Biliar , Colestasis , Stents
2.
International Journal of Biomedical Engineering ; (6): 350-353,361,后插3, 2016.
Artículo en Chino | WPRIM | ID: wpr-606061

RESUMEN

Objective To investigate the influence of polyethylene glycol (PEG) on heparin release of heparinloaded polycaprolactone/polyethylene glycol (PCL/PEG) membranes used in artificial vascular peosthesis.Methods Heparin-loaded PCL/PEG membrane samples with different PEG mass contents of 0,0.5%,10% and 15% were prepared by blending method and freeze-drying technology.The influence of PEG on heparin release was experimental studied in vitro.The influence of PEG on the structural characteristics of the samples were investigated by X-ray diffraction,Fourier transform infrared spectrum and differential scanning calorimeter.Results The addition of PEG reduced the heparin release resistance.The results showed that the average release rate of heparin in the first day and the release amount for 34 d were improved.Both these parameters increased with the increase of PEG mass content.The X-ray diffraction,Fourier transform infrared spectroscopy and differential scanning calorimetry showed that the crystallinity of PCL membrane was slightly enhanced by the addition of heparin,but the overall effect was not significant.In addition,the addition of heparin could promote the crystalline grain growth of PEG,and a common distribution of heparin and PEG in the matrix was observed.Conclusions The heparin release control can be achieved by adjusting the PEG mass content in heparin-loading PCL/PEG membranes prepared by blending method and freeze-drying technology.The proposed samples may have anticoagulant effect,which can be expected to be used as small-diameter artificial vascular prosthesis material.

3.
Chinese Journal of Immunology ; (12)1986.
Artículo en Chino | WPRIM | ID: wpr-674644

RESUMEN

Recurent spontaneous abortion (RSA) was classified into the primary (1?) and the sec-ondary (2?) according to patients histoty.Occurence of blocking antibodies between them wasinvestigated with mixed lymphocyte reaction—blocking assay and complement dependent cyto-toxicity assay.It was found that the primary abortion had been mainly caused by lack of block-ing antibodies,the secondary abortion without lack of blocking antibodies.Thus,the primaryabortion is different from the secondary abortion in aspects of immune aetiology and immunemechanisms although their clinical manifestations are similar.