Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
2.
Arch. endocrinol. metab. (Online) ; 63(2): 128-136, Mar.-Apr. 2019. tab, graf
Artículo en Inglés | LILACS | ID: biblio-1001219

RESUMEN

ABSTRACT Objective: Nonalcoholic fatty liver disease is the commonest diffuse liver disease, of which women with polycystic ovary syndrome are at an increased risk. The aim of the present study was to assess the diagnostic value of the semiquantitative strain parameters of real-time ultrasound elastography for nonalcoholic fatty liver disease in patients with polycystic ovary syndrome. Subjects and methods: Thirty-five polycystic ovary syndrome patients with nonalcoholic fatty liver disease, 70 polycystic ovary syndrome patients without nonalcoholic fatty liver disease, and 70 healthy female controls of reproductive age were included. All participants underwent ultrasonic examination and semiquantitative analysis of real-time ultrasound elastography of the liver. Results: Main semi quantitative strain parameters, such as average strain value, differed significantly among groups polycystic ovary syndrome with nonalcoholic fatty liver disease, polycystic ovary syndrome without nonalcoholic fatty liver disease, and control (87.02 ± 10.16 vs. 96.31 ± 11.44 vs. 104.49 ± 7.28, p < 0.001). Clinical and laboratory parameters differed significantly between the two subgroups with low or high average strain value. For diagnostic value of average strain value for elevated aminotransferase, the area under the curve was 0.808 (range 0.721-0.895). In multiple linear regression analysis, polycystic ovary syndrome, waist circumference, and metabolic syndrome were stand-alone independent factors associated with average strain value among subjects without nonalcoholic fatty liver disease. Conclusion: Semiquantitative real-time ultrasound elastography analysis could distinguish liver parenchyma alterations in patients with polycystic ovary syndrome more sensitively. The diagnostic value of the proposed method for nonalcoholic fatty liver disease need further research.


Asunto(s)
Humanos , Femenino , Adulto , Adulto Joven , Síndrome del Ovario Poliquístico/diagnóstico por imagen , Diagnóstico por Imagen de Elasticidad/métodos , Enfermedad del Hígado Graso no Alcohólico/diagnóstico por imagen , Síndrome del Ovario Poliquístico/fisiopatología , Presión Sanguínea , Procesamiento de Imagen Asistido por Computador , Índice de Masa Corporal , Sensibilidad y Especificidad , Diagnóstico Diferencial , Circunferencia de la Cintura , Enfermedad del Hígado Graso no Alcohólico/fisiopatología , Tejido Parenquimatoso/fisiopatología , Tejido Parenquimatoso/diagnóstico por imagen , Transaminasas/sangre , Menstruación/fisiología
3.
Clinics ; 71(4): 199-204, Apr. 2016. tab, graf
Artículo en Inglés | LILACS | ID: lil-781425

RESUMEN

OBJECTIVE: To determine whether the gross tumor volume of resectable gastric adenocarcinoma on multidetector computed tomography could predict the presence of regional lymph node metastasis and could determine N categories. MATERIALS AND METHODS: A total of 202 consecutive patients with gastric adenocarcinoma who had undergone gastrectomy 1 week after contrast-enhanced multidetector computed tomography were retrospectively identified. The gross tumor volume was evaluated on multidetector computed tomography images. Univariate and multivariate analyses were performed to determine whether the gross tumor volume could predict regional lymph node metastasis, and the Mann-Whitney U test was performed to compare the gross tumor volume among N categories. Additionally, a receiver operating characteristic analysis was performed to identify the accuracy of the gross tumor volume in differentiating N categories. RESULTS: The gross tumor volume could predict regional lymph node metastasis (p<0.0001) in the univariate analysis, and the multivariate analyses indicated that the gross tumor volume was an independent risk factor for regional lymph node metastasis (p=0.005, odds ratio=1.364). The Mann-Whitney U test showed that the gross tumor volume could distinguish N0 from the N1-N3 categories, N0-N1 from N2-N3, and N0-N2 from N3 (all p<0.0001). In the T1-T4a categories, the gross tumor volume could differentiate N0 from the N1-N3 categories (cutoff, 12.3 cm3), N0-N1 from N2-N3 (cutoff, 16.6 cm3), and N0-N2 from N3 (cutoff, 24.6 cm3). In the T4a category, the gross tumor volume could differentiate N0 from the N1-N3 categories (cutoff, 15.8 cm3), N0-N1 from N2-N3 (cutoff, 17.8 cm3), and N0-N2 from N3 (cutoff, 24 cm3). CONCLUSION: The gross tumor volume of resectable gastric adenocarcinoma on multidetector computed tomography could predict regional lymph node metastasis and N categories.


Asunto(s)
Humanos , Masculino , Femenino , Adulto , Persona de Mediana Edad , Anciano , Adulto Joven , Neoplasias Gástricas/patología , Adenocarcinoma/secundario , Carga Tumoral , Tomografía Computarizada Multidetector/métodos , Ganglios Linfáticos/diagnóstico por imagen , Pronóstico , Neoplasias Gástricas/cirugía , Neoplasias Gástricas/diagnóstico por imagen , Adenocarcinoma/cirugía , Adenocarcinoma/diagnóstico por imagen , Variaciones Dependientes del Observador , Análisis Multivariante , Estudios Retrospectivos , Curva ROC , Neoplasias Glandulares y Epiteliales/patología , Ganglios Linfáticos/patología , Metástasis Linfática , Estadificación de Neoplasias
4.
Indian J Pathol Microbiol ; 2012 Jul-Sept 55(3): 314-318
Artículo en Inglés | IMSEAR | ID: sea-142259

RESUMEN

Background: Tissue microarray (TMA) is a novel and useful tool to efficiently analyze gene expression in histological tissues. Aim: Cost-efficient and easy to use automated tissue arrayers will provide a better instrumentation to generate TMAs. Thus, we designed and produced our tissue microarrayer to meet these needs. Materials and Methods: The HT-1 tissue microarrayer we designed and manufactured consists primarily of four parts, including an instrument to make array pores for the recipient paraffin blocks, a punch needle, an instrument for negative-pressure embedding, and a special manipulator. By using the HT-1, 14 different TMAs were made to accommodate 312 cases of tissues and TMA sections were tested by hematoxylin-eosin (H&E) staining, in situ hybridization, and immunohistochemistry. Results: Expand: Hematoxylin and eosin staining showed that the tissue cylinders were similar, even, and in order on the slides. Most importantly, the HT-1 microarrayer can make array pores in the recipient paraffin block with a single application in seconds. The HT-1 also contains a unique negative pressure system for embedding TMA blocks. In addition, HT-1 can make tissue cylinders with the same levels and depth for equally embedded and sectioning. Conclusions: The HT-1 tissue microarrayer is a device that is simple, economical and easy to use.


Asunto(s)
Automatización/economía , Automatización/métodos , Humanos , Patología Molecular/economía , Patología Molecular/métodos , Análisis de Matrices Tisulares/economía , Análisis de Matrices Tisulares/métodos
5.
Clinics ; 67(6): 609-614, 2012.
Artículo en Inglés | LILACS | ID: lil-640211

RESUMEN

OBJECTIVE: The aim of this study was to determine whether and how the diameter of the vein that gives rise to the inflowing vein of the esophageal and gastric fundic varices secondary to posthepatitic cirrhosis, as measured with multidetector-row computed tomography, could predict the varices and their patterns. METHODS: A total of 106 patients with posthepatitic cirrhosis underwent multidetector-row computed tomography. Patients with and without esophageal and gastric fundic varices were enrolled in Group 1 and Group 2, respectively. Group 1 was composed of Subgroup A, consisting of patients with varices, and Subgroup B consisted of patients with varices in combination with portal vein-inferior vena cava shunts. The diameters of the originating veins of veins entering the varices were reviewed and statistically analyzed. RESULTS: The originating veins were the portal vein in 8% (6/75) of patients, the splenic vein in 65.3% (49/75) of patients, and both the portal and splenic veins in 26.7% (20/75) of patients. The splenic vein diameter in Group 1 was larger than that in Group 2, whereas no differences in portal vein diameters were found between groups. In Group 1, the splenic vein diameter in Subgroup A was larger than that in Subgroup B. A cut-off splenic vein diameter of 8.5 mm achieved a sensitivity of 83.3% and specificity of 58.1% for predicting the varices. For discrimination of the varices in combination with and without portal vein-inferior vena cava shunts, a cut-off diameter of 9.5 mm achieved a sensitivity of 66.7% and specificity of 60.0%. CONCLUSION: The diameter of the splenic vein can be used to predict esophageal and gastric fundic varices and their patterns.


Asunto(s)
Adolescente , Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Adulto Joven , Várices Esofágicas y Gástricas/patología , Hipertensión Portal/patología , Cirrosis Hepática/patología , Vena Porta/patología , Vena Esplénica/patología , Hipertensión Portal/etiología , Cirrosis Hepática/complicaciones , Tomografía Computarizada Multidetector , Variaciones Dependientes del Observador , Tamaño de los Órganos , Valor Predictivo de las Pruebas , Curva ROC
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA