Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Añadir filtros








Intervalo de año
1.
Arq. bras. oftalmol ; 82(5): 394-399, Sept.-Oct. 2019. graf
Artículo en Inglés | LILACS | ID: biblio-1019429

RESUMEN

ABSTRACT Purpose: Punctal stenosis can result in symptoms such as epiphora and can significantly reduce the quality of life of patients. Perforated punctal plug insertion is an easy procedure that is commonly used as the first step of treatment for punctal stenosis. Methods: Clinical, demographic, and outcome data were retrospectively collected for 54 eyes of 21 males and 11 females who consecutively presented to our Oculoplastic Clinic and underwent silicone Micro Flow perforated punctal plug insertion. All patients had epiphora with punctal stenosis. Results: Of the 54 plugs, 26 plugs (48.1%) were lost and 28 (51.8%) stayed in place. Of the latter, eight were explanted because of the occlusion of the plug with secretions and recurrent conjunctivitis; moreover, two plugs migrated deep into the vertical canaliculus. Of the 54 plugs, only 18 (33.3%) were well-tolerated with significant symptomatic improvement. Conclusion: Plug loss is a prominent problem in patients implanted with perforated punctal plugs. Silicone punctal plugs failed in 66.7% of our patients over a mean follow-up of 14.2 months.


RESUMO Objetivo: A estenose punctal pode resultar em sintomas como a epífora e diminuir significativamente a qua­lidade de vida dos pacientes. A inserção de um tampão perfurado é um procedimento fácil que é comumente usado como o primeiro passo do tratamento para a estenose punctal. Métodos: Dados clínicos, demográficos e de resultado foram coletados retrospectivamente de 54 olhos de 21 homens e 11 mulheres que consecutivamente se apresentaram em nossa Clínica de Oculoplástica e foram submetidos a inserção de um tampão de silicone perfurado Micro Flow. Todos os pacientes tinham epífora com estenose punctal. Resultados: Dos 54 tampões, 26 (48,1%) foram perdidos e 28 (51,8%) permaneceram no local. Destes últimos, 8 foram removidos devido a oclusão do tampão com secreção e conjuntivite recorrente, além disso, 2 migraram profundamente no canalículo vertical. Dos 54 tampões, apenas 18 (33,3%) foram bem tolerados com significativa melhora dos sintomas. Conclusão: A perda de tampões é um problema de destaque em pacientes implantados com tampões perfurados. Tampões de silicone falharam em 66,7% dos pacientes durante um seguimento médio de 14,2 meses.


Asunto(s)
Humanos , Masculino , Femenino , Adolescente , Adulto , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Adulto Joven , Siliconas/administración & dosificación , Síndromes de Ojo Seco/cirugía , Tapones Lagrimales/efectos adversos , Aparato Lagrimal/cirugía , Obstrucción del Conducto Lagrimal/terapia , Prótesis e Implantes , Lágrimas , Síndromes de Ojo Seco/complicaciones , Implantación de Prótesis , Obstrucción del Conducto Lagrimal/etiología
2.
Arq. bras. oftalmol ; 78(3): 150-153, May-Jun/2015. tab, graf
Artículo en Inglés | LILACS | ID: lil-753025

RESUMEN

ABSTRACT Purpose: The contrast sensitivity (CS) function in patients with primary Sjögren’s syndrome (pSS) may be impaired either frequently as a result of dry eye diseases or rarely as a result of optic neuropathy. In this study, we aimed to evaluate the CS function in pSS patients as well as to assess corneal aberrations and thickness of the peripapillary retinal nerve fiber layer (pRNFL). Methods: Fourteen eyes of 14 pSS patients (pSS group) and 14 eyes of 14 healthy participants (control group) were subjected to assessment of CS at the spatial frequencies of 1.5, 3.0, 6.0, 12, and 18 cycles/degree (cpd) using a functional visual acuity contrast test (FACT); measurement of corneal high-order aberrations (HOAs) in terms of coma-like, spherical-like, and total HOAs using Scheimpflug corneal topography; and measurement of the thickness of both the macular ganglion cell-inner plexiform layer (mGCIPL) and pRNFL in all quadrants using optical coherence tomography. None of the participants were under treatment with artificial tears. Results: The results of the CS test did not differ between the 2 groups at all spatial frequencies (p>0.05). In addition, there were no statistically significant differences between the 2 groups in terms of corneal HOAs (p>0.05) and thickness of mGCIPL (p>0.05). However, among all quadrants, only the inferior quadrant of pRNFL in pSS patients was statistically significantly thinner than that in the healthy participants (p=0.04). Conclusions: The CS function in pSS patients can be maintained with normal thickness of both pRNFL and mGCIPL and with lack of increased corneal HOAs, which may be present even in the absence of artificial tear usage. .


RESUMO Objetivo: A função de sensibilidade ao contraste em pacientes com síndrome de Sjögren primário (pSS) pode ser prejudicada, quer frequentemente como resultado de doenças do olho seco, ou mais raramente como um resultado de neuropatia óptica. Neste estudo, objetivamos avaliar a função de sensibilidade ao contraste de pacientes com pSS, além da avaliação das aberrações da córnea e a espessura da camada de fibras nervosas da retina (pRNFL). Métodos: Catorze olhos de 14 pacientes com pSS e 14 olhos de 14 participantes saudáveis foram submetidos, respectivamente, à avaliação do teste de sensibilidade aos contrastes (CS) nas frequências espaciais de 1,5, 3,0, 6,0, 12 e 18 ciclos/grau (cpd), utilizando teste de contraste acuidade visual funcional (FACT); a medida das aberrações de alta ordem da córnea (HOAs) em termos de coma, aberrações esféricas e aberrações totais, utilizando topografia corneana por Scheimpflug; e medida de espessura da camada de macular de células ganglionares plexiforme interna (mGCIPL) e a espessura de pRNFL em todos os quadrantes usando tomografia de coerência óptica. Nenhum dos participantes estava sob tratamento com lágrimas artificiais. Resultados: O teste CS em pacientes pSS não diferiu do que o teste CS em participantes saudáveis em todas as frequências espaciais (p>0,05). Não houve também nenhuma diferença estatisticamente significativa entre os dois grupos em termos de HOAs da córnea (p>0,05), e espessura de mGCIPL (p>0,05). No entanto, entre todos os quadrantes, apenas o quadrante inferior da pRNFL em pacientes pSS foi significativamente mais fino que o quadrante inferior da pRNFL em participantes saudáveis (p=0,04). Conclusões: A função de CS em doentes com pSS pode ser mantida em condições de ambas as espessuras normais de pRNFL e mGCIPL, assim como nas condições de falta de aumento HOAs da córnea, que pode ser mantida, mesmo na ausência do uso de lágrimas artificiais. .


Asunto(s)
Adulto , Femenino , Humanos , Masculino , Persona de Mediana Edad , Sensibilidad de Contraste/fisiología , Síndrome de Sjögren/fisiopatología , Córnea/fisiopatología , Aberración de Frente de Onda Corneal/fisiopatología , Fibras Nerviosas , Estudios Prospectivos , Síndrome de Sjögren/diagnóstico , Tomografía de Coherencia Óptica/métodos , Agudeza Visual , Pruebas de Visión/métodos
3.
Rev. bras. anestesiol ; 65(1): 41-46, Jan-Feb/2015. tab, graf
Artículo en Inglés | LILACS | ID: lil-736169

RESUMEN

BACKGROUND AND OBJECTIVES: Changes in ocular perfusion play an important role in the pathogenesis of ischemic optic neuropathy. Ocular perfusion pressure is equal to mean arterial pressure minus intraocular pressure. The aim of this study was to evaluate the changes in the intraocular pressure and the retinal nerve fiber layer thickness in patients undergoing spinal surgery in the prone position. METHODS: This prospective study included 30 patients undergoing spinal surgery. Retinal nerve fiber layer thickness were measured one day before and after the surgery by using optical coherence tomography. Intraocular pressure was measured by tonopen six times at different position and time-duration: supine position (baseline); 10 min after intubation (Supine 1); 10 (Prone 1), 60 (Prone 2), 120 (Prone 3) min after prone position; and just after postoperative supine position (Supine 2). RESULTS: Our study involved 10 male and 20 female patients with the median age of 57 years. When postoperative retinal nerve fiber layer thickness measurements were compared with preoperative values, a statistically significant thinning was observed in inferior and nasal quadrants (p = 0.009 and p = 0.003, respectively). We observed a statistically significant intraocular pressure decrease in Supine 1 and an increase in both Prone 2 and Prone 3 when compared to the baseline. Mean arterial pressure and ocular perfusion pressure were found to be significantly lower in Prone 1, Prone 2 and Prone 3, when compared with the baseline. CONCLUSIONS: Our study has shown increase in intraocular pressure during spinal surgery in prone position. A statistically significant retinal nerve fiber layer thickness thinning was seen in inferior and nasal quadrants one day after the spinal surgery. .


JUSTIFICATIVA E OBJETIVOS: As alterações de perfusão ocular desempenham um papel importante na patogênese da neuropatia óptica isquêmica. A pressão de perfusão ocular é igual à pressão arterial média menos a pressão intraocular. O objetivo deste estudo foi avaliar as alterações da pressão intraocular e da espessura da camada de fibras nervosas da retina em pacientes submetidos à cirurgia da coluna vertebral em pronação. MÉTODOS: Este estudo prospectivo incluiu 30 pacientes submetidos à cirurgia da coluna vertebral. A espessura da camada de fibras nervosas da retina foi medida um dia antes e um depois da cirurgia, com o uso da tomografia de coerência óptica. A pressão intraocular foi medida seis vezes com o Tonopen e o tempo de duração em posições diferentes: em supinação (basal), 10 minutos após a intubação (Supinação 1); após a pronação aos 10 minutos (Pronação 1), 60 minutos (Pronação 2) e 120 minutos (Pronação 3) e logo após a supinação no período pós-operatório (Supinação 2). RESULTADOS: Nosso estudo envolveu 10 pacientes do sexo masculino e 20 do feminino, com média de 57 anos. No pós-operatório, quando as medidas da espessura da camada de fibras nervosas da retina foram comparadas com os valores do pré-operatório, um afinamento estatisticamente significativo da retina foi observado nos quadrantes nasais e inferiores (p = 0,009 e p = 0,003, respectivamente). Observamos uma diminuição da pressão intraocular estatisticamente significante em Supinação 1 e um aumento em ambos momentos Pronação 2 e Pronação 3, em comparação com os valores basais. A pressão arterial média e a pressão de perfusão ocular foram significativamente mais baixas em Pronação 1, Pronação 2 e Pronação 3, em comparação com os valores basais. CONCLUSÕES: Nosso estudo mostrou aumento da pressão intraocular durante a cirurgia da coluna vertebral em pronação. Um afinamento estatisticamente significante da espessura da camada de fibras nervosas da retina foi observado ...


JUSTIFICACIÓN Y OBJETIVOS: Las alteraciones en la perfusión ocular desempeñan un rol importante en la patogénesis de la neuropatía óptica isquémica. La presión de perfusión ocular es igual a la presión arterial media menos la presión intraocular. El objetivo de este estudio fue evaluar las alteraciones de la presión intraocular y del espesor de la capa de fibras nerviosas de la retina en pacientes sometidos a cirugía de la columna vertebral en pronación. MÉTODOS: Este estudio prospectivo incluyó a 30 pacientes sometidos a cirugía de la columna vertebral. El espesor de la capa de fibras nerviosas de la retina se midió un día antes y uno después de la cirugía, con la tomografía de coherencia óptica. La presión intraocular se midió 6 veces con tonopen y el tiempo de duración en posiciones diferentes: en supinación (basal), 10 min después de la intubación (supinación 1); después de la pronación a los 10 min (pronación 1), 60 min (pronación 2) y 120 min (pronación 3), y justo después de la supinación en el período postoperatorio (supinación 2). RESULTADOS: Nuestro estudio contó con la participación de 10 pacientes del sexo masculino y 20 del femenino, con un promedio de edad de 57 años. En el postoperatorio, cuando las medidas del espesor de la capa de fibras nerviosas de la retina fueron comparadas con los valores del preoperatorio, se observó un adelgazamiento estadísticamente significativo de la retina en los cuadrantes nasales e inferiores (p = 0,009 y p = 0,003, respectivamente). Observamos una disminución de la presión intraocular estadísticamente significativa en supinación 1 y un aumento en pronación 2 y 3, en comparación con los valores basales. La presión arterial media y la presión de perfusión ocular fueron significativamente más bajas en pronación 1, pronación 2 y pronación 3, en comparación con los valores basales. CONCLUSIONES: Nuestro estudio mostró un aumento de la presión intraocular durante la cirugía de la columna vertebral ...


Asunto(s)
Humanos , Persona de Mediana Edad , Retina , Columna Vertebral/cirugía , Pronación , Presión Intraocular , Estudios Prospectivos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA