Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
Braz. j. infect. dis ; 21(3): 297-305, May-June 2017. tab
Artículo en Inglés | LILACS | ID: biblio-839207

RESUMEN

ABSTRACT The present study evaluated several techniques currently available (commercial kits and in-house assays) for diagnosing human T lymphotropic viruses types 1 and 2 in two groups of patients enrolled at HIV/AIDS specialized care services in São Paulo: Group 1 (G1), n = 1608, 1237 male/371 female, median age 44.3 years old, majority using highly active antiretroviral therapy (HAART); G2, n = 1383, 930 male/453 female, median age of 35.6 years old, majority HAART naïve. Enzyme immunoassays [(EIA) Murex and Gold ELISA] were employed for human T lymphotropic viruses types 1 and 2 screening; Western blotting (WB), INNO-LIA (LIA), real-time PCR pol (qPCR), and nested-PCR-RFLP (tax) were used to confirm infection. Samples were considered human T lymphotropic viruses types 1 and 2 positive when there was reactivity using at least one of the four confirmatory assays. By serological screening, 127/2991 samples were positive or borderline, and human T lymphotropic virus infection was confirmed in 108 samples (three EIA-borderline): 56 human T lymphotropic virus type 1 [G1 (27) + G2 (29)]; 45 human T lymphotropic virus type 2 [G1 (21) + G2 (24)]; one human T lymphotropic virus type 1 + human T lymphotropic virus type 2 (G2); six human T lymphotropic virus [G1 (2) + G2 (4)]. Although there were differences in group characteristics, human T lymphotropic viruses types 1 and 2 prevalence was similar [3.1% (G1) and 4.2% (G2), p = 0.113]. The overall sensitivities of LIA, WB, qPCR, and PCR-RFLP were 97.2%, 82.4%, 68.9%, and 68.4%, respectively, with some differences among groups, likely due to the stage of human T lymphotropic virus infection and/or HAART duration. Indeterminate immunoblotting results were detected in G2, possibly due to the seroconversion period. Negative results in molecular assays could be explained by the use of HAART, the occurrence of defective provirus and/or the low circulating proviral load. In conclusion, when determining the human T lymphotropic virus infection, the findings highlight that there is a need to consider the blood samples with borderline results in screening assays. Of all the tested assays, LIA was the assay of choice for detecting human T lymphotropic virus type 1 and human T lymphotropic virus type 2 in human immunodeficiency virus type 1-infected patients.


Asunto(s)
Humanos , Masculino , Femenino , Adulto , Infecciones por HTLV-I/diagnóstico , Infecciones por HTLV-II/diagnóstico , Infecciones por VIH/complicaciones , ADN Viral/genética , Ensayo de Inmunoadsorción Enzimática , Anticuerpos Anti-HTLV-I/sangre , Infecciones por HTLV-I/complicaciones , Anticuerpos Anti-HTLV-II/sangre , Infecciones por HTLV-II/complicaciones , Western Blotting , Sensibilidad y Especificidad , Reacción en Cadena en Tiempo Real de la Polimerasa
2.
Braz. j. infect. dis ; 21(3): 297-305, may.-jun. 2017. tab
Artículo en Inglés | SES-SP, LILACS, SESSP-IALPROD, SES-SP, SESSP-IALACERVO | ID: biblio-1123368

RESUMEN

The present study evaluated several techniques currently available (commercial kits and in-house assays) for diagnosing human T lymphotropic viruses types 1 and 2 in two groups of patients enrolled at HIV/AIDS specialized care services in São Paulo: Group 1 (G1), n = 1608, 1237 male/371 female, median age 44.3 years old, majority using highly active antiretroviral therapy (HAART); G2, n = 1383, 930 male/453 female, median age of 35.6 years old, majority HAART naïve. Enzyme immunoassays [(EIA) Murex and Gold ELISA] were employed for human T lymphotropic viruses types 1 and 2 screening; Western blotting (WB), INNO-LIA (LIA), real-time PCR pol (qPCR), and nested-PCR-RFLP (tax) were used to confirm infection. Samples were considered human T lymphotropic viruses types 1 and 2 positive when there was reactivity using at least one of the four confirmatory assays. By serological screening, 127/2991 samples were positive or borderline, and human T lymphotropic virus infection was confirmed in 108 samples (three EIA-borderline): 56 human T lymphotropic virus type 1 [G1 (27) + G2 (29)]; 45 human T lymphotropic virus type 2 [G1 (21) + G2 (24)]; one human T lymphotropic virus type 1 + human T lymphotropic virus type 2 (G2); six human T lymphotropic virus [G1 (2) + G2 (4)]. Although there were differences in group characteristics, human T lymphotropic viruses types 1 and 2 prevalence was similar [3.1% (G1) and 4.2% (G2), p = 0.113]. The overall sensitivities of LIA, WB, qPCR, and PCR-RFLP were 97.2%, 82.4%, 68.9%, and 68.4%, respectively, with some differences among groups, likely due to the stage of human T lymphotropic virus infection and/or HAART duration. Indeterminate immunoblotting results were detected in G2, possibly due to the seroconversion period. Negative results in molecular assays could be explained by the use of HAART, the occurrence of defective provirus and/or the low circulating proviral load. In conclusion, when determining the human T lymphotropic virus infection, the findings highlight that there is a need to consider the blood samples with borderline results in screening assays. Of all the tested assays, LIA was the assay of choice for detecting human T lymphotropic virus type 1 and human T lymphotropic virus type 2 in human immunodeficiency virus type 1-infected patients. (AU)


Asunto(s)
Humanos , Masculino , Femenino , Pacientes , Virus Linfotrópico T Tipo 1 Humano , Virus Linfotrópico T Tipo 2 Humano , Immunoblotting , Infecciones por VIH , Reacción en Cadena de la Polimerasa , VIH-1 , Terapia Antirretroviral Altamente Activa
3.
Rev. Inst. Adolfo Lutz (Online) ; 74(1): 57-65, 2015. tab, graf
Artículo en Portugués | LILACS, SES-SP | ID: lil-783223

RESUMEN

O presente estudo pesquisou o melhor algoritmo de testes laboratoriais para efetuar o diagnóstico de infecção por vírus linfotrópicos de células T humanas dos tipos 1 (HTLV-1) e 2 (HTLV-2) em pacientes HIV-1 positivos. Amostras de sangue de 1.608 pacientes do CRT DST/Aids-SP foram analisadas quanto à presença de anticorpos específicos usando-se dois ensaios de triagem (EIA Murex HTLV-I+II e Gold ELISA HTLV-I/II), dois confirmatórios [HTLV Blot 2.4 (Western Blot – WB) e INNO-LIA HTLV I/II (Line ImmunoAssay - LIA)] e um molecular (PCR em tempo real pol). Na triagem foram detectados 51(Murex) e 49 (Gold ELISA) soros reagentes. Pelo WB, 23 soros confirmaram infecção por HTLV-1, 12 HTLV-2, seis HTLV e nove apresentaram perfis indeterminados. O LIA detectou 24 soros HTLV-1 positivos, 20 HTLV-2 e seis HTLV. A PCR evidenciou segmento pol de HTLV-1 em 18 e HTLV-2 em 12 amostras de sangue. Pelos testes confirmatórios, em 50 pacientes foi confirmada a infecção por HTLV: 25 HTLV-1 (1,55 %), 21 HTLV-2 (1,31 %) e quatro HTLV (0,25 %). As sensibilidades do LIA, WB e PCR foram de 96 %, 76 % e 60 %, respectivamente. Considerando-se apenas o custo, o melhor algoritmo diagnóstico para população infectada pelo HIV-1 foi o uso da PCR seguida do LIA...


Asunto(s)
Humanos , VIH-1 , Coinfección , Infecciones por HTLV-I/diagnóstico , Infecciones por HTLV-II/diagnóstico , Serodiagnóstico del SIDA , Prueba de Laboratorio
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA