Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Añadir filtros








Intervalo de año
1.
Journal of Biomedical Engineering ; (6): 125-128, 2006.
Artículo en Chino | WPRIM | ID: wpr-309869

RESUMEN

PEG (Mn = 1000)-segmented polyurethanes, with hard segment percentage of 40%, 50% and 55% and named PU-H40, PU-H50 and PU-H55 respectively, were synthesized by bulk polymerization. The structure of PU was characterized by FTIR, DSC, and GPC. Mechanical properties, water contact angles and water vapor transmit rate(WVTR) were also tested. FTIR and DSC showed that the degree of microphase separation increased with the hard content. Mechanical test showed the tensile strength of PU-H50 to be 25 MPa, the highest tensile strength of the PU series. By the use of PEG as soft segment, the surface hydrophilicity of the materials increased dramatically. Owing to its high degree of microphase separation and the mobility of soft segment, the water contact angle of PU-H55 attained to 33 degrees. The WVTRs of PU-H40, PU-H50 and PU-H55 were 789 g/m2/24h, 705 g/m2/24h and 623g/m2/24h respectively. These data suggest that the materials are suitable for fabricating such biomedical articles as surgical gloves, wound dressing and medical protective coating.


Asunto(s)
Humanos , Materiales Biocompatibles , Química , Polietilenglicoles , Química , Poliuretanos , Química , Espectroscopía Infrarroja por Transformada de Fourier , Propiedades de Superficie
2.
Journal of Biomedical Engineering ; (6): 734-738, 2005.
Artículo en Chino | WPRIM | ID: wpr-238353

RESUMEN

Adopting the two-step method and changing the proportion between PEG (Polyethylene glycol) and PTMG (poly (tetrahydrofuran), we used the MDI (4,4'-diphenylmethane diisocyanate) and short chain extender BDO (1,4-butanediol) as hard segment, the PTMG and PEG as soft segment, and hence prepared a series of polyether-based thermoplastic polyurethanes. FTIR showed the structure character of these polyurethanes. The determination of mechanics property and water contact angles revealed their good mechanics properties and hydrophilicity. Blood compatibility was evaluated by hemolysis test and platelet adhesion test, which revealed their good hemocompatibility. So those polyurethanes may be of wide application in the future.


Asunto(s)
Animales , Conejos , Materiales Biocompatibles , Química , Butileno Glicoles , Química , Isocianatos , Química , Ensayo de Materiales , Polietilenglicoles , Química , Polímeros , Química , Poliuretanos , Química
3.
Journal of Biomedical Engineering ; (6): 273-276, 2003.
Artículo en Chino | WPRIM | ID: wpr-311057

RESUMEN

The one-step method was adopted in this study to synthesize aliphatic polyurethane with 4,4-methylene dicyclohexyl diisocyanate(HMDI), 1,4-butanediol (BDO) and poly (tetrahydrofuran) (PTMG). The tests conducted on this material were: FIR spectrum, mechanical properties test, water contact angles test, hemolysis test and platelet adhesion test. Results showed that this material has a good tensile strength up to 30 Mpa, similar to aromaphatic polyurethane. But its tensile elongation, tensile permanent change, hydrophility are better than those of aromaphatic polyurethane. The hemolysis test and platelet adhesion test showed that it has good blood compatibility.


Asunto(s)
Animales , Conejos , Materiales Biocompatibles , Química , Toxicidad , Técnicas In Vitro , Ensayo de Materiales , Adhesividad Plaquetaria , Poliuretanos , Química , Toxicidad , Espectroscopía Infrarroja por Transformada de Fourier , Propiedades de Superficie , Resistencia a la Tracción
4.
Journal of Biomedical Engineering ; (6): 315-319, 2002.
Artículo en Chino | WPRIM | ID: wpr-263600

RESUMEN

Polyurethanes are popularly used in cardiovascular and other biomedical fields due to their good biocompatibility as well as mechanical properties. But they are subject to biodegradation in vivo for a long time, and cause inflammation, so improving the biocompatibility of medical polyurethanes is an important subject of biomaterials. Recent researches have focused on biological modelling of biomaterials for improving the biocompatibility of polyurethanes. This paper reviews two main methods for improving biocompatibility of polyurethanes-endothelial cells seeding and mimic biomembrane (phospholipid surface), and summarizes the main procedures and questions of these two methods.


Asunto(s)
Humanos , Materiales Biocompatibles , Química , Células Endoteliales , Fosfolípidos , Química , Poliuretanos , Química
5.
Journal of Biomedical Engineering ; (6): 17-19, 2002.
Artículo en Chino | WPRIM | ID: wpr-334340

RESUMEN

In this article, the blood compatibility of polyurethanes (PUs) made by ourselves for catheters is studied by hemolysis test, platelets adhesion test, kinetic thrombus time test and dynamic clot formation. The results showed that these PUs all have excellent blood compatibility. Among these PUs, H50-100 and H60-100 have best blood compatibility. Additionally, the relationship between the structure and blood compatibility is discussed.


Asunto(s)
Animales , Conejos , Materiales Biocompatibles , Sangre , Pruebas de Coagulación Sanguínea , Cateterismo , Técnicas In Vitro , Ensayo de Materiales , Pruebas de Función Plaquetaria , Poliuretanos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA