Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Añadir filtros








Intervalo de año
1.
Artículo en Inglés | WPRIM | ID: wpr-1043047

RESUMEN

The clustered regularly interspaced short palindromic repeats (CRISPR) system, a rapidly advancing genome editing technology, allows DNA alterations into the genome of organisms. Gene editing using the CRISPR system enables more precise and diverse editing, such as single nucleotide conversion, precise knock-in of target sequences or genes, chromosomal rearrangement, or gene disruption by simple cutting. Moreover, CRISPR systems comprising transcriptional activators/repressors can be used for epigenetic regulation without DNA damage. Stem cell DNA engineering based on gene editing tools has enormous potential to provide clues regarding the pathogenesis of diseases and to study the mechanisms and treatments of incurable diseases. Here, we review the latest trends in stem cell research using various CRISPR/Cas technologies and discuss their future prospects in treating various diseases.

2.
Artículo en Coreano | WPRIM | ID: wpr-967842

RESUMEN

Purpose@#To compare the horizontal white-to-white (WTW) diameter measured using four devices. @*Methods@#We measured the horizontal WTW diameter of 52 eyes of 52 patients using the IOL Master 500, ANTERION, OA-2000, and Pentacam HR devices. Repeated-measures analysis of variance was used to compare the measurements. Correlations between the measurements were evaluated using the Pearson correlation test. Agreement between measurements obtained using different instruments was confirmed using a Bland-Altman plot. @*Results@#The mean horizontal WTW diameters obtained using IOL Master 500, ANTERION, OA-2000, and Pentacam HR were 11.65 ± 0.39, 11.52 ± 0.44, 11.51 ± 0.52, and 11.28 ± 0.41 mm, respectively. The horizontal WTW diameters obtained using IOL Master 500 and Pentacam HR were the largest and smallest, respectively. There was a statistically significant difference in mean diameter between IOL Master 500 and ANTERION (p = 0.03), as well as between Pentacam HR and the remaining three devices (all p 0.6, p < 0.001). The 95% limits of agreement between the measurements were 0.808-1.619 mm. @*Conclusions@#There were statistically significant differences in horizontal WTW diameter between IOL Master 500 and ANTERION, and between IOL Master 500 and Pentacam HR, but not between IOL Master 500 and OA-2000. Measurements obtained using IOL Master 500 and the remaining three devices are not interchangeable because of their low level of agreement.

3.
Artículo en Coreano | WPRIM | ID: wpr-926314

RESUMEN

Purpose@#This study reports a case of meibomian gland dysfunction associated with bortezomib, which is a treatment of choice for multiple myeloma.Case summary: A 59‐year‐old female patient presented to our hospital with a complaint of dryness that had worsened for 2 months and eye discharges that were difficult to remove even after washing her face. The patient had been diagnosed with multiple myeloma 5 months prior and had undergone four cycles of bortezomib therapy. Slit‐lamp microscopy revealed a number of pouting of the meibomian gland (MG) orifices in both eyes. Meibography revealed that more than one‐third and less than twothirds of the total MG area of both upper lids were lost and more than two‐thirds of the total MG area of both lower lids were lost. No clinically significant improvements were noted at 8 months despite thorough eyelid hygiene therapy, including warm compresses, topical antibiotics, steroids, and artificial tears. However, when the patient revisited our clinic 2 months after completing bortezomib treatment, the subjective symptoms had improved and all of the pouting of MG orifices had disappeared. There was no significant difference in the MG dropout area for either eye compared with the observations from a previous visit during bortezomib treatment. @*Conclusions@#Clinicians should be aware that MG dysfunction may occur or worsen in patients receiving bortezomib treatment and should consider this when establishing a treatment plan for meibomian dysfunction or when educating patients.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA