Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Añadir filtros








Intervalo de año
1.
Artículo en Chino | WPRIM | ID: wpr-400243

RESUMEN

Objective To explore the ultrasonographical characteristics of placental abruption, especially the light placental abruption that was diagnosed by color Doppler ultrasonic combining with enhancement Doppler E-flow imaging, providing diagnosis data for clinical treatment. Methods With color Doppler ultrasonic and enhancement Doppler E-flow imaging, an analysis was made on the ultrasonography and clinical result of 50 patients with heavy placental abruption and 23 patients with light placental abruption. Results The diagnosis and clinical treatment of 50 patients with heavy placental abruption who had been diagnosed by color Doppler ultrasonic combining with enhancement Doppler E-flow imaging were in conformity with the postnatal pathological diagnosis. The coincidence rate in diagnosis was 100%. Of 23 patients with light placental abruption who had been diagnosed by color Doppler ultrasonic combining with enhancement E-flow Doppler imaging, 19 cases' diagnosis and clinical treatment were in accordance with their postnatal pathological diagnosis and the coincidence rate was 83%, 4 cases were misdiagnosis and missed diagnosis. Of 73 patients with placental abruption, 60 cases were carried out caesarean birth and 13 cases performed natural labor. Conclusion The enhancement Doppler E-flow imaging combining with color Doppler ultrasonic can accurately diagnose the heavy placental abruption and also provide a new method for the diagnosis of light placental abruption and perform a dynamic monitoring for the treatment transfer result of it.

2.
Artículo en Chino | WPRIM | ID: wpr-597416

RESUMEN

Objective To explore the application of high-frequency color Doppler in the diagnosis of infant intussusception and the selection of reduction mode according tO the hemodynamic situations of intussusception intestine tube and blood vessel in mesentery.Methods A total of 377 cases of doubtful intussusception infants wete checked by high-frequency color Doppler.After they had been diagnosed,the hemodynamic situations of intussuscepiton intestine tube and blood vessel in mesentery were carefully observed and the ultra-sound had 3 types and then the hydrostatic enema reduction was chosen as treatment method.Results A total of 263 cases was diagnosed by highfrequency colot Doppler with rate of coincidence of 100%.Among them are 253 successful cases reduced by hydrostatic enema.The successful rate of reduction was 96.2%and the 10 failed cases were changed to be treated bv operation.The intestinal wall of intussusception tube in failure group had serious dropsy without blood flow shown.Conclusions It is accurate that the infant intussusception is diagnosed by high-frequency color Doppler.According to the hemodynamic situations of intussusceptin intestine tube and blood vessel in mesentery,the infant intussusception can be divided into 3 types as follows:type Ⅰ:the blood signal of intestinal tube and wall is up or normal,which shall be reduced by hydrostatic enema;type Ⅱ:the blood signal of intestinal tube and wall is small with high obstruction index,which shall be reduced by hydrostatic enema as possible as it can;type Ⅲ:the intestinal wall has serious dropsy with rather high obstruction index and without blood flow shown,in which the hydrostatic enema redHetion shall bebanned and the operation shall be carried out as soon as possible.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA