Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Añadir filtros








Intervalo de año
1.
Military Medical Sciences ; (12): 814-817,826, 2013.
Artículo en Chino | WPRIM | ID: wpr-598607

RESUMEN

Objective To calculate the electric field intensity and transmembrane voltage of spherical cells and ellipsoi -dal red blood cells ( RBC) in an extremely low frequency electromagnetic field .Through this calculation , we can provide reference to the search for interaction targets and mechanics between the extremely low frequency electromagnetic field and organisms.Methods The Finite Element Method was used in the numerical computation for the spherical cell model and the ellipsoidal RBC model .Results The electric field intensity of the two types of cells on the cellular membrane was both significantly higher than the applied electric field strength , and the values of the induced field strength and transmembrane voltage varied with the direction of the electric field periodically .Conclusion The cell shape and direction of the applied electric field are not the main determinants of the cellular membrane electric field intensity and the transmembrane voltage compared with electromagnetic parameters .The distribution of the electric field intensity and transmembrane voltage are re-lated to the direction of the applied electric field.

2.
Chinese Journal of Radiological Medicine and Protection ; (12): 432-434,448, 2009.
Artículo en Chino | WPRIM | ID: wpr-597290

RESUMEN

Objective To establish an efficiency calibration method without a radioactive source for Inspector 2000 gamma spectroscopy system.Methods At the fwst step,geometry parameters of the detector were properly specified by comparisons of FEPE(Full Energy Peak Efficiency)between Monte Carlo(MC)calculations and the average measured values of HPGe and NaI detectors using point sources(137 Cs).The differences between calculations and measurements were generally within ±10% for gamma rays.Then,Monte Carlo simulation was used to evaluate the counting efficiency of Nal(TI)and HPGe detectors for BOMAB phantoms.Corresponding efficiency curves and functions were fitted.Results The counting efficiency received from the fitted efficiency functions had a good agreement with those from MC simulation.The bias for Nal detector ranged from-19% to 18%,while the bias for HPGe detector ranged from-11% to 17%.The above errors were totally acceptable in the on-site deployment during nuclear and radiological emergency events.Conclusions Monte Carlo method is simple,time and laborsaving in determing the counting efficiency of gamma spectroscopy system.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA