Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Añadir filtros








Intervalo de año
1.
Arq. bras. oftalmol ; 87(1): e2021, 2024. tab, graf
Artículo en Inglés | LILACS-Express | LILACS | ID: biblio-1527823

RESUMEN

ABSTRACT Purpose: To present long-term results of pars plana vitrectomy combined with pan-retinal endolaser photocoagulation, Ahmed glaucoma valve implantation, and/or phacoemulsification in patients with complicated neovascular glaucoma. Methods: The study comprised 15 eyes from 15 patients with neovascular glaucoma as a complication of diabetic retinopathy and owing to ischemic central retinal vein occlusion. There was a vitreous hemorrhage n all of the patients. Furthermore, 8 of the cases showed varying degrees of hyphema. All subjects received an intravitreal injection of bevacizumab three days before surgery. In 12 phakic patients, phacoemulsification, pars plana vitrectomy, and Ahmed glaucoma valve implantation were performed. Pars plana vitrectomy and Ahmed glaucoma valve implantation were performed in 3 pseudophakic patients. Perioperative and postoperative complications, intraocular pressure values, and best-corrected visual acuity scores were also recorded. Results: The mean follow-up was 24.4 ± 14.56 months. The mean preoperative intraocular pressure was 50.06 ± 7.6 mmHg. At 1 day, 7 days, and 1-, 3-, 6-, 12-month, and last visit following surgery, the mean intraocular pressure was 11.06 ± 8.22, 12.66 ± 7.27, 13.8 ± 7.73, 18.64 ± 7.05, 19.28 ± 4.61, 16.28 ± 1.68, and 16.92 ± 2.12 mmHg, respectively (p=0.001 for every follow-up visit). The mean visual acuity on the most recent appointment was 1.18 ± 0.42 logMar (p=0.001 for each subsequent visit). As postoperative early complications, varying degrees of hyphema and fibrin reactions were recorded. During follow-up, one patient developed phthisis bulbi. In 4 cases, Ahmed glaucoma valve revision surgery was required. Conclusions: In patients with complicated neovascular glaucoma, combined surgical procedures are safe, effective, and preferable both in terms of controlling high intraocular pressure and providing reasonable visual abilities.


RESUMO Objetivo: Apresentar nossos resultados de longo período de vitrectomia pars plana combinada com fotocoagulação panretiniana com endolaser, implantação da válvula Ahmed para glaucoma e/ou facoemulsificação em pacientes com glaucoma neovascular complicado. Métodos: Foram incluídos no estudo 15 olhos de 15 pacientes com glaucoma neovascular como complicação da retinopatia diabética e devido à oclusão isquêmica da veia central da retina. Todos os casos tiveram hemorragia vítrea. Além disso, 8 dos casos apresentaram diferentes graus de hifema. A injeção intravítrea de bevacizumabe foi administrada em todos os casos 3 dias antes da cirurgia. Facoemulsificação, vitrectomia pars plana e implantação da válvula Ahmed para glaucoma foram realizadas em 12 pacientes fáquicos. A vitrectomia pars plana e a implantação da válvula Ahmed para glaucoma foram realizadas em 3 pacientes pseudofáquicos. Complicações perioperatórias e pós-operatórias, valores de pressão intraocular e valores de melhor acuidade visual corrigida pré-operatório e pós-operatório foram registrados. Resultados: O acompanhamento médio foi de 24,4 ± 14,56 meses. A média da pressão intraocular pré-operatória foi de 50,06 ± 7,6 mmHg. Em 1 dia, 7 dias e 1,3,6,12 meses, e última visita após cirurgia, a média da pressão intraocular foi de 11,06 ± 8,22, 12,66 ± 7,27, 13,8 ± 7,73, 18,64 ± 7,05, 19,28 ± 4,61, 16,28 ± 1,68 e 16,92 ± 2,12 mmHg, respectivamente (p=0,001 para cada visita de acompanhamento). A média da acuidade visual na última visita foi de 1,18 ± 0,42 logMar (p=0,001 para cada visita de acompanhamento). Vários graus de reações de hifema e fibrina foram registrados como complicações precoces pós-operatórias. Phthisis bulbi foi desenvolvido em um caso durante o acompanhamento. A cirurgia de revisão da válvula Ahmed para glaucoma foi necessária em 4 casos. Conclusões: Os procedimentos cirúrgicos combinados que realizamos são seguros, eficazes e preferenciais, tanto em termos de controle da alta pressão intraocular quanto fornecimento de habilidades visuais razoáveis em pacientes com glaucoma neovascular complicado.

2.
J. pediatr. (Rio J.) ; 93(4): 413-419, July-Aug. 2017. tab, graf
Artículo en Inglés | LILACS | ID: biblio-894035

RESUMEN

Abstract Objective: To assess if magnetic resonance enterography is capable of showing evidence/extent of disease in pediatric patients with biopsy-proven celiac disease by comparing with a control group, and to correlate the magnetic resonance enterography findings with anti-endomysial antibody level, which is an indicator of gluten-free dietary compliance. Methods: Thirty-one pediatric patients (mean age 11.7 ± 3.1 years) with biopsy-proven celiac disease and 40 pediatric patients as a control group were recruited in the study. The magnetic resonance enterography images of both patients with celiac disease and those of the control group were evaluated by two pediatric radiologists in a blinded manner for the mucosal pattern, presence of wall thickening, luminal distention of the small bowel, and extra-intestinal findings. Patient charts were reviewed to note clinical features and laboratory findings. The histopathologic review of the duodenal biopsies was re-conducted. Results: The mean duration of the disease was 5.6 ± 1.8 years (range: 3-7.2 years). In 24 (77%) of the patients, anti-endomysial antibody levels were elevated (mean 119.2 ± 66.6 RU/mL). Magnetic resonance enterography revealed normal fold pattern in all the patients. Ten (32%) patients had enlarged mesenteric lymph nodes. Conclusion: Although a majority of the patients had elevated anti-endomysial antibody levels indicating poor dietary compliance, magnetic resonance enterography did not show any mucosal abnormality associated with the inability of magnetic resonance enterography to detect mild/early changes of celiac disease in children. Therefore, it may not be useful for the follow-up of pediatric celiac disease.


Resumo Objetivo: Avaliar se a enterografia por ressonância magnética (ERM) consegue comprovar/mostrar a extensão da doença em pacientes pediátricos com doença celíaca (DC) comprovada por biópsia, comparar com um grupo de controle e correlacionar os achados da ERM com o nível de anticorpo antiendomísio (EMA) indicador de dieta sem glúten. Métodos: Foram recrutados 31 pacientes pediátricos (idade média entre 11,7 ± 3,1 anos) com DC comprovada por biópsia e 40 pacientes pediátricos em um grupo de controle. As imagens da ERM dos pacientes com DC e no grupo de controle foram avaliadas por dois radiologistas pediátricos às cegas para o padrão da mucosa, presença de espessamento da parede, dilatação luminal do intestino delgado e achados extraintestinais. Os prontuários dos pacientes foram revisados para anotação de características clínicas e achados laboratoriais. A avaliação histopatológica das biópsias duodenais foi feita novamente. Resultados: A duração média da doença foi 5,6 ± 1,8 anos (faixa de 3-7,2 anos). Em 24 (77%) dos pacientes, os níveis EMA estavam elevados (média 119,2 ± 66,6 RU/mL). A ERM revelou um padrão de pregas normal em todos os pacientes; 10 (32%) dos pacientes apresentaram gânglios linfáticos mesentéricos aumentados. Conclusão: Apesar de a maioria dos pacientes ter níveis elevados de EMA, o que indica uma dieta pobre, a ERM não mostrou anomalia na mucosa associada à incapacidade de a ERM detectar alterações leves/precoces de DC nas crianças. Portanto, ela pode não ser útil no acompanhamento da DC pediátrica.


Asunto(s)
Humanos , Masculino , Femenino , Niño , Adolescente , Espectroscopía de Resonancia Magnética/métodos , Enfermedad Celíaca/diagnóstico por imagen , Intestino Delgado/diagnóstico por imagen , Estudios de Casos y Controles , Enfermedad Celíaca/patología , Estudios Prospectivos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Intestino Delgado/patología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA