Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Añadir filtros








Intervalo de año
1.
Chinese Journal of Endocrinology and Metabolism ; (12): 966-969, 2020.
Artículo en Chino | WPRIM | ID: wpr-870122

RESUMEN

Two cases of solitary fibrous tumor (SFT) with endocrine manifestations as the first symptom were investigated through comprehensively reviewing their medical history and clinical records. One case of recurrent giant solitary fibrous tumor of the thoracic cavity had repeated dizziness, palpitation and limb weakness for one month. The patient had hypoglycemia accompanied with significantly decreased serum insulin, and the ratio of insulin-like growth factor Ⅱ(IGF-Ⅱ) and insulin-like growth factor Ⅰ (IGF-Ⅰ) was greater than 10. Non-islet cell tumor hypoglycemia (NICTH) should be considered in the patient. Another case was found to have thyroid gland SFT and developed distant metastasis. The patient presented with hypoglycemia, hypokalemia and possible consumptive hypothyroidism. Clinicians should improve our understanding of the endocrine manifestations of the disease. SFT may occur in endocrine glands (such as thyroid), and may also present as NICTH and consumptive hypothyroidism.

2.
Journal of Practical Stomatology ; (6): 19-23, 2016.
Artículo en Chino | WPRIM | ID: wpr-485953

RESUMEN

Objective:To evaluate the translucency,opalescence and fluorescence reflection of 6 light-cured resin composites. Methods:Disks of 6 resin composites including Filtek Supreme XT-YT(XT),Filtek Supreme XT-A3B(3M),Clearfil Majesty-A3 (MJ),Gradia Direct-A3(GC),Venus-A3(VE)and Charisma Diamond-A3(CA)were prepared in the diameter of 9 mm with the thickness 2.0 mm.PR-650 spectral scanning colorimeter was used to measure and caculate translucency parameters(TP),opal-escence parameter(OP)and fluorescence reflection(FL)and to draw the fluorescence reflection curves.Results:Except XT and MJ,TP value of other resin composites were in the range of natural tooth.Only OP value of XT was in the range of natural tooth en-amel.FL value of XT was close to that of natural tooth dentin.Fluorescent peak wavelength of GC,MJ,VE and CA were in the range of natural tooth,but fluorescent peak height was higher than that of natual tooth.TP was positively correlated with OP(r =0.85,P <0.05).There was no statistic correlation between TP and FL,between OP and FL.Conclusion:The 6 resin composites can simulate optical property of natual tooth,but the opalescence of resin composites is defective.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA