Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Añadir filtros








Intervalo de año
1.
World Journal of Emergency Medicine ; (4): 290-293, 2013.
Artículo en Inglés | WPRIM | ID: wpr-789637

RESUMEN

@#BACKGROUND: This study aimed to observe the effect of hemoperfusion (HP) cartridge on different internal environment indicators at different time points in patients with acute blood poisoning and to find alternative indicators for the detection of blood poisoning. METHODS: The levels of internal environment indicators (blood pH, PvCO2, PvO2, blood lactate, potassium, free calcium, bicarbonate, and blood glucose) before and after HP treatment were recorded for patients with acute poisoning at time points of 30 minutes and 120 minutes. After calculating the difference value δ, the statistical software was used to analyze the statistical difference of the influencea-v caused by HP cartridge at two time points. According to the formula, adsorption rate %= —— ×100, thea adsorption rate of each indicator was calculated respectively. RESULTS: The difference of indicators at different time points in inlet and outlet such as blood glucose, free-calcium, and lactate was statistically significant (P<0.05), but the difference in indicators such as pH, PvCO2, PvO2, potassium, sodium, and bicarbonate was not statistical y significant (P>0.05). CONCLUSION: During HP treatment, the indicators of blood glucose, free-calcium and lactate were significantly affected by HP cartridge, and the effect varies with time.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA