Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Añadir filtros








Intervalo de año
1.
Rev. Assoc. Med. Bras. (1992) ; 67(1): 58-63, Jan. 2021. tab
Artículo en Inglés | LILACS | ID: biblio-1287799

RESUMEN

SUMMARY BACKGROUND: Percutaneous mitral balloon valvuloplasty and mitral valve replacement have been the treatment options for mitral stenosis for several years, however, studies that compare these two modalities are very rare in the literature. ObjectIve: In this article, we aim to investigate the comparison of clinical results of percutaneous mitral balloon valvuloplasty and mitral valve replacement. Methods: 527 patients with rheumatic mitral stenosis, treated with percutaneous mitral balloon valvuloplasty or mitral valve replacement (276 patients with percutaneous mitral balloon valvuloplasty and 251 patients with mitral valve replacement) from 1991 to 2012 were evaluated. The demographic characteristics, clinical, echocardiographic and catheterization data of patients were evaluated retrospectively. The results of early and late clinical follow-up of patients after percutaneous mitral balloon valvuloplasty and mitral valve replacement were also evaluated. Results: The mean follow-up time of the percutaneous mitral balloon valvuloplasty group was 4.7 years and, for the mitral valve replacement-group, it was 5.45 years. The hospital stay of the percutaneous mitral balloon valvuloplasty group was shorter than that of the mitral valve replacement group (2.02 days vs 10.62 days, p<0.001). The hospital mortality rate of percutaneous mitral balloon valvuloplasty and mitral valve replacement were 0% and 2% respectively (p=0.024). In the percutaneous mitral balloon valvuloplasty group, early postprocedural success rate was 92.1%. The event-free survival of percutaneous mitral balloon valvuloplasty and mitral valve replacement was found to be similar. While reintervention was higher in percutaneous mitral balloon valvuloplasty-group (p<0.001), mortality rate was higher in mitral valve replacement-group (p<0.001). Conclusion: Percutaneous mitral balloon valvuloplasty seems to be more advantageous than mitral valve replacement due to low mortality rates, easy application of the procedure and no need for general anesthesia.


Asunto(s)
Humanos , Valvuloplastia con Balón , Estenosis de la Válvula Mitral/cirugía , Estenosis de la Válvula Mitral/diagnóstico por imagen , Estudios Retrospectivos , Estudios de Seguimiento , Válvula Mitral/cirugía , Válvula Mitral/diagnóstico por imagen
2.
Rev. bras. cir. cardiovasc ; 35(6): 950-957, Nov.-Dec. 2020. tab, graf
Artículo en Inglés | LILACS, SES-SP | ID: biblio-1143986

RESUMEN

Abstract Introduction: Heparin-induced thrombocytopenia (HIT) is a potentially lethal complication of unfractionated or low-molecular weight heparin therapy. We aimed to determine the incidence and mortality rate of patients with positive heparin/platelet factor 4 (PF4) antibodies, which is a rapid detection test of HIT. Methods: Coronary artery bypass grafting and mitral and aortic valve surgeries were evaluated. Cardiopulmonary bypass was employed in all patients. The diagnosis of HIT was based on immunological assays. Postoperative complications, mortality rates, and the causes of death were specified in patients with positive heparin/PF4 antibodies. Results: Postoperative thrombocytopenia was detected in 257 patients. Twenty of these patients undergoing open heart surgery were included in the final analysis. Antibodies against heparin/PF4 complex were positive in 20 patients. The mean body mass index was 28.8±2.3 kg/m2, mean value of left ventricular ejection fraction was 48.3±6.7%, cardiopulmonary bypass time was 113.0±35.0 min, aortic cross-clamping time was 88.0±32.7 min, mean intensive care unit length of stay was 10.9±4.9 days, mean preoperative platelet count was 307.250±88528 platelets/microliter, and mean postoperative platelet count was 243.050±89.354 platelets/microliter. The mean duration of heparin exposure was 6.9±2.9 days. The mortality rate was 45% (nine patients) and 1.2% (three patients) in heparin/PF4 complex positive and negative patients, respectively. Conclusion: Although the incidence of HIT was low in patients undergoing open heart surgery, an increased rate of early mortality was observed in patients with positive heparin/PF4 antibodies.


Asunto(s)
Humanos , Masculino , Femenino , Factor Plaquetario 4 , Heparina/efectos adversos , Volumen Sistólico , Estudios Retrospectivos , Función Ventricular Izquierda
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA