Chinese Journal of Preventive Medicine ; (12): 1047-1058, 2023.
Artículo en Chino | WPRIM | ID: wpr-985515

RESUMEN

Objective: Compare and analyze the results of the domestic Lanyi AH600 glycated hemoglobin analyzer and other different detection systems to understand the comparability of the detection results of different detectors, and establish the best cut point of Lanyi AH600 determination of haemoglobin A1c (HbA1c) in the diagnosis of diabetes. Methods: Multi center cohort study was adopted. The clinical laboratory departments of 18 medical institutions independently collected test samples from their respective hospitals from March to April 2022, and independently completed comparative analysis of the evaluated instrument (Lanyi AH600) and the reference instrument HbA1c. The reference instruments include four different brands of glycosylated hemoglobin meters, including Arkray, Bio-Rad, DOSOH, and Huizhong. Scatter plot was used to calculate the correlation between the results of different detection systems, and the regression equation was calculated. The consistency analysis between the results of different detection systems was evaluated by Bland Altman method. Consistency judgment principles: (1) When the 95% limits of agreement (95% LoA) of the measurement difference was within 0.4% HbA1c and the measurement score was≥80 points, the comparison consistency was good; (2) When the measurement difference of 95% LoA exceeded 0.4% HbA1c, and the measurement score was≥80 points, the comparison consistency was relatively good; (3) The measurement score was less than 80 points, the comparison consistency was poor. The difference between the results of different detection systems was tested by paired sample T test or Wilcoxon paired sign rank sum test; The best cut-off point of diabetes was analyzed by receiver operating characteristic curve (ROC). Results: The correlation coefficient R2 of results between Lanyi AH600 and the reference instrument in 16 hospitals is≥0.99; The Bland Altman consistency analysis showed that the difference of 95% LoA in Nanjing Maternity and Child Health Care Hospital in Jiangsu Province (reference instrument: Arkray HA8180) was -0.486%-0.325%, and the measurement score was 94.6 points (473/500); The difference of 95% LoA in the Tibetan Traditional Medical Hospital of TAR (reference instrument: Bio-Rad Variant II) was -0.727%-0.612%, and the measurement score was 89.8 points; The difference of 95% LoA in the People's Hospital of Chongqing Liang Jiang New Area (reference instrument: Huizhong MQ-2000PT) was -0.231%-0.461%, and the measurement score was 96.6 points; The difference of 95% LoA in the Taihe Hospital of traditional Chinese Medicine in Anhui Province (reference instrument: Huizhong MQ-2000PT) was -0.469%-0.479%, and the measurement score was 91.9 points. The other 14 hospitals, Lanyi AH600, were compared with 4 reference instrument brands, the difference of 95% LoA was less than 0.4% HbA1c, and the scores were all greater than 95 points. The results of paired sample T test or Wilcoxon paired sign rank sum test showed that there was no statistically significant difference between Lanyi AH600 and the reference instrument Arkray HA8180 (Z=1.665,P=0.096), with no statistical difference. The mean difference between the measured values of the two instruments was 0.004%. The comparison data of Lanyi AH600 and the reference instrument of all other institutions had significant differences (all P<0.001), however, it was necessary to consider whether it was within the clinical acceptable range in combination with the results of the Bland-Altman consistency analysis. The ROC curve of HbA1c detected by Lanyi AH600 in 985 patients with diabetes and 3 423 patients with non-diabetes was analyzed, the area under curve (AUC) was 0.877, the standard error was 0.007, and the 95% confidence interval 95%CI was (0.864, 0.891), which was statistically significant (P<0.001). The maximum value of Youden index was 0.634, and the corresponding HbA1c cut point was 6.235%. The sensitivity and specificity of diabetes diagnosis were 76.2% and 87.2%, respectively. Conclusion: Among the hospitals and instruments currently included in this study, among these four hospitals included Nanjing Maternity and Child Health Care Hospital in Jiangsu Province (reference instrument: Arkray HA8180), Tibetan Traditional Medical Hospital of TAR (reference instrument: Bio-Rad Variant Ⅱ), the People's Hospital of Chongqing Liang Jiang New Area (reference instrument: Huizhong MQ-2000PT), and the Taihe Hospital of traditional Chinese Medicine in Anhui Province (reference instrument: Huizhong MQ-2000PT), the comparison between Lanyi AH600 and the reference instruments showed relatively good consistency, while the other 14 hospitals involved four different brands of reference instruments: Arkray, Bio-Rad, DOSOH, and Huizhong, Lanyi AH600 had good consistency with its comparison. The best cut point of the domestic Lanyi AH600 for detecting HbA1c in the diagnosis of diabetes is 6.235%.


Asunto(s)
Embarazo , Niño , Humanos , Femenino , Hemoglobina Glucada , Estudios de Cohortes , Diabetes Mellitus/diagnóstico , Sensibilidad y Especificidad , Curva ROC
2.
Chinese Journal of Nosocomiology ; (24)2005.
Artículo en Chino | WPRIM | ID: wpr-685669

RESUMEN

OBJECTIVE To provide gists for educations about AIDS control through finding out the knowledge among medical staff at a low infected area.METHODS The questionnaires including 30 questions of 5 kinds were analyzed.RESULTS The awareness rate of total knowledge among medical staff was 64.94%.The positive rate about common knowledge was upon 88%.But the rate about comprehensive knowledge such as diagnosis standard,therapy way,disinfection measure,career defending,law function,and so on was law.The correct answers on 17 questions among nurses were higher than doctors(P

3.
Chinese Journal of Nosocomiology ; (24)1994.
Artículo en Chino | WPRIM | ID: wpr-685257

RESUMEN

OBJECTIVE To investigate the application of antibacterials in patients accepted operation in grass-roots(hospitals),so to standardize the application of antibacterials and cut down the medical cost.METHODS Full-time administrators for nosocomial infection investigated the application of antibacterials in patients who accepted(operation) in Sep 2004,and filled in the questionnaires.RESULTS In 1 383 cases of 11 hospitals the application rate of antibacterials was 98.63%;in which 86.50% were for prophylactic usage and 13.50% for therapeutic usage;(29.90%) for single antibiotics treatment and 50.15% for bigeminy,18.70% were for trigeminy.Time of(application) differentiated(6.90,7.00,6.60d) fromⅠto Ⅲ kinds of operation.Per capita cost of antibacterials was $956.50(47.60%).CONCLUSIONS High cost of antibacterials results from such factors as multiple kinds,long time and(combined) application.