Chinese Journal of Medical Physics ; (6): 1578-1580, 2010.
Artículo en Chino | WPRIM | ID: wpr-500192

RESUMEN

Objective:To implement rapid acquisition gradient echo(RAGE)pulse sequence in clinical MRI scaner.Methods:Pascal language is engaged to edit source code.Number of slice excited,order of phase encoded,phase recycle of RF pulse,NEX,on/off of the gradients,and so on are all controlled by sequence parameters.SI×N_(phase)×N_(slice) data of 32 bctys were allocated to restore the k space.Source code of sequence was compiled with executable file and is loaded to RINMR software.Image of human brain are acquired.The experiment has been conducted on 0.36T permanent MRI system.Resuits:In the case of 256×256 matrix acquisition,time of single slice is 4 seconds.The resolution and SNR of the image are all adquately satisfy the clinical application.

2.
Journal of Biomedical Engineering ; (6): 1211-1213, 2009.
Artículo en Chino | WPRIM | ID: wpr-244660

RESUMEN

In this paper are analyzed the disadvantages of CGO-3000 digital subtraction angiography table Operating Box. The authors put forward a communication control scheme between single-chip microcomputer(SCM) and programmable logic controller(PLC). The details of hardware and software of communication are given.


Asunto(s)
Humanos , Angiografía de Substracción Digital , Diseño de Equipo , Procesamiento de Imagen Asistido por Computador , Microcomputadores , Intensificación de Imagen Radiográfica , Programas Informáticos
3.
Chinese Journal of Radiology ; (12): 1056-1058, 2008.
Artículo en Chino | WPRIM | ID: wpr-398345

RESUMEN

Objective To explore the relationship between image quality and different exposure intensity of digital radiography(DR).Methods Using a contrast-detail phantom Cdrad 2.0,observers evaluated images on the monitots when exposure parameters were 90 kV and mAs ranged from 0.5 to 16.0 mAs.Then calculate image quality figure(IQF),and ANOVA was used to analyze the difference of IQF under different radiation dose in 8 subjects.Results (1)When exposure parameters were 90 kV and mAs altered from 0.5 to 8.0 mAs.the IQF observed on the monitor was reduced,and the minimal value was 38.54±2.82.When mAs changing from 8.0 to 16.0 mAs.IQF observed on the monitor was increased,and the maximum was 44.33±2.35.(2)Under the different exposure condition,the difference of IQF values were statistically significant(F=60.35,P<0.01).Conclusions With the increased exposure intensity,the image quality on monitor increased.When mAs was 8.0 mAs,image quality was the optimum When mAs was more than 8.0 mAs,the image quality on monitor reduced.

4.
Orthopedic Journal of China ; (24): 1187-1188, 2005.
Artículo en Chino | WPRIM | ID: wpr-409524

RESUMEN

Intelligentized muti-functional limb treatment and rehabilitation based on micro-computer is introduced in this paper. It is mainly used for rehabilitation in the disablement of limb. The range speed and training time can be automatically controlled. Training parameter and result can be monitored on computer. The apparatus has the advantages of high reliability, easy operation and compact design. It is a new kind of intelligent limb rehabilitation.

5.
Chinese Medical Equipment Journal ; (6)1989.
Artículo en Chino | WPRIM | ID: wpr-586283

RESUMEN

Although the type of XHD150B-IO 800mA X-ray machine possesses a damage protection electric circuit for the main thyristors, with the first switch of photographic hand valve pressed, abnormal instant exposure still appears when double (in different phase) or more than three main thyristors are broken through, short-circuited or mis-energized, and consequently the high voltage element or X-ray machine will break down. Therefore the original electric circuit must be improved. Material: A few of leads. Method: We exchange the conjunction sequence of three NO (normal open) contacting points of radiograph high voltage preparing work relay--MAG SW- R with three reverse parallel connection of main thyristors. Conclusion: The normal procedure of radiographic exposure won't be disturbed after the improvement. When whichever one or more than two main thyristors is broken through, short-circuited or mis-energized, the spoilage can be detected instantly and the protection circuit works correspondingly, which guarantees the safety of X-ray machine.