Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Añadir filtros








Intervalo de año
1.
Journal of Modern Laboratory Medicine ; (4): 143-144,147, 2017.
Artículo en Chino | WPRIM | ID: wpr-610894

RESUMEN

Objective To evaluate the comparability of the test results of two immunoassay systems based on the electrochemical luminescence and the fluorescence lateral flow immunoassay for serum procalcitonin (PCT).Methods Roche cobas system was used as the reference system,and fluorescence lateral flow immunoassay system of Shanghai Upper biotech company was used as evaluated system.A total of 141 clinical samples during November,2015 were detected by the two systems to obtain the correlation coefficient and the Kappa values at the two cutoff values(0.5,2.0 ng/ml).Results The two systems showed high correlation (Y=1.008X-0.032,r=0.995,P<0.001) and low deviation (t=-0.230,P=0.819>0.05) without statistic significance between two methods.Kappa values were 0.944,0.943 respectively at the two cutoff values (0.5,2.0 ng/ml).Conclusion The test results showed no significant difference between the two immunoassay systems,suggesting a consistency between them for clinical detection of PCT.All the observed indicators reached the clinical diagnostic requirements and the method of quantitative detection of PCT by fluorescence lateral flow immunoassya can be applied for the quick detection of clinical human PCT.

2.
International Journal of Laboratory Medicine ; (12): 1779-1780,1783, 2017.
Artículo en Chino | WPRIM | ID: wpr-621042

RESUMEN

Objective To retrospectively analyse the detection results of human leukocyte antigen(HLA) B27,and discuss its diagnosis value in disease such as ankylosing spondylitis(AS).Methods HLA-B27 detection was performed on 1 335 suspected AS patients treated in the hospital from January 2015 to June 2016 by using multiparameter flow cytometry instrument.The test results showed 201 patients were diagnosed with AS(AS group),1 134 patients were diagnosed with rheumatoid arthritis and other related diseases (non AS group).The test results were shown by using mean fluorescence intensity and positive lymphocyte expression rate.n addition,120 healthy people were enrolled as the control group in the physical examination center of the hospital.Results The positive rate of HLA-B27 screening in suspected AS patients was 15.73% (210/1 335),and the positive rate of HLA-B27 screening in the control group was 2.50% (3/120).The positive rate of HLA-B27 screening,the rate of cell expression and the average fluorescence intensity of AS group were 92.03%(185/201),(85.34±17.99)%,8.74±4.20,significantly higher than the non AS group and the control group(P0.05).HLA-B27 screening positive patients were mainly concentrated in adolescence,and the positive rate of male was higher than that of female (P<0.05).Conclusion Flow cytometry examination of HLA-B27 can provide important basis for the diagnosis and differential diagnosis of AS.

3.
Chinese Journal of Radiological Medicine and Protection ; (12): 951-954, 2016.
Artículo en Chino | WPRIM | ID: wpr-505434

RESUMEN

Writing and publishing scientific papers is a very important part of the research work.The quality of the thesis is also an important indicator to measure the achievements of scientific research workers.The quality of the thesis mainly includes the academic quality and the writing quality,but some of the researchers are mostly proficient in practice and neglect the writing,so there are still many writing problems in the manuscript.By reading the submission specification,this article summarizes the common problems in the writing,so as to provide the reference value for the readers.

4.
China Medical Equipment ; (12): 14-16,17, 2015.
Artículo en Chino | WPRIM | ID: wpr-602798

RESUMEN

Objective:To solve the inaccurate results caused by the aging of nitrocellulose membranes in qualitative or quantitative immuno-colloidal gold infiltration tests.Methods: Using qualitative TB-DOT and quantitative HCG-DOT immuno-colloidal gold filtration test systems, we compared the treated coloration, circulation velocity, adsorbing power and stability of nitrocellulose membrane of good quality, 3-methyl-1-butanol treated and untreated aged membranes. Results: Abundant results has approved that the regeneration of aged nitrocellulose membrane by 3-methyl-1-butanol treatment lead to 14.4% faster flow velocity, stronger absorption capability, better stability, and lower CV value, compared to untreated membranes.Conclusion:The mentioned method solves the problem caused by the aging of nitrocellulose membranes, and assures the accuracy of measurements. Furthermore, it is an universal solution that can be applied to other POCT products.

5.
Chinese Pharmacological Bulletin ; (12)1986.
Artículo en Chino | WPRIM | ID: wpr-550639

RESUMEN

Quercetin (0.05~0.20 mmol/L, final concentration) obviously inhibited the aggregation and production of PGE2 and TXB2 of human PMN which were induced by AA ( 0.66 mmol/L), LTB4 ( 0.002 mmol/L) and the fourth composition of cobra venom of Guangxi Province ( 4.8mg/L) in vitro. These effects were dose dependent, the IDg50 of PMN aggregation induced by AA, LTB4 and the fourth composition of cobra venom of Guangxi Province was 68?mol/L, 59?mol/L and 61?mol/L respectively. At the concentration of 0.50?mol/L, it can also inhibit lysozyme release of PMN induced by AA, LTB4 and the fourth composition of cobra venom of Guangxi Province.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA