Arq. bras. cardiol ; 74(6): 513-8, June 2000. ilus, tab
Artículo en Portugués, Inglés | LILACS | ID: lil-265661

RESUMEN

Coronary dissection occurs frequently and in several degrees during coronary angioplasty, which is one of the mechanisms for increasing the lumen diameter of a vessel. However the length of the dissection may affect the procedure, becoming the most frequent cause of total occlusion after coronary angioplasty. We report here a case of extensive dissection that occurred during the coronary angioplasty of a focused lesion, which we treated with two long stents.


Asunto(s)
Humanos , Femenino , Persona de Mediana Edad , Angioplastia Coronaria con Balón/efectos adversos , Enfermedad Coronaria/terapia , Vasos Coronarios/lesiones , Stents , Enfermedad Coronaria/etiología