Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Journal of Biomedical Engineering ; (6): 1375-1378, 2010.
Artículo en Chino | WPRIM | ID: wpr-260874

RESUMEN

A new head and neck location frame for positron emission tomography (PET) and computed tomography (CT) cross-modality medical image fusion in radiotherapy was developed. The solid mark bars of N form in the old designed CT location frame were replaced by closed hollow pipes which could be filled with different developer solutions before CT or PET scan, respectively. Nine points of external marker used for registration and fusion were obtained in CT images and PET images, respectively. The locations of the two sets of nine points showed the method of registration to be effective and accurate in achieving the PET and CT image fusion. This method, based on its characteristics of simple structure and easy-to-use, can be of wide application in clinical setting.


Asunto(s)
Humanos , Cabeza , Diagnóstico por Imagen , Interpretación de Imagen Asistida por Computador , Métodos , Imagen Multimodal , Métodos , Cuello , Diagnóstico por Imagen , Tomografía de Emisión de Positrones , Métodos , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador , Métodos , Tomografía Computarizada por Rayos X , Métodos
2.
Chinese Medical Equipment Journal ; (6)2004.
Artículo en Chino | WPRIM | ID: wpr-589430

RESUMEN

Objective To help the hospitals at all levels in China to realize IMRT by adding the accurate location equipments and TPS based on the existing general radiation therapy from research of the new method for static Intensity-modulated radiation therapy. Method Based on the controlled technique of CRT, a new split method for fabricating the three-dimensional physics compensator to achieve the IMRT was developed. Results The Experiment manifested that the compensator fabricated by the way could make the high dosage shape of target in accordance with the form of tumor and could adjust the distribution of the dosage according to remedy requirement. Conclusion The method is simple and feasible, and has brilliant clinical prospective and popularized significance.

3.
Chinese Medical Equipment Journal ; (6)2003.
Artículo en Chino | WPRIM | ID: wpr-590021

RESUMEN

Objective To design a radiotherapy information system with high statistical function.Methods The whole system included foreground workstation and background database server system.The software of foreground workstation was developed under Visual C#.NET,and SQL Server 2005 was accessed by using ADO.NET.Results Radiotherapy Information System could provide basic information,diagnosis information,therapy information and follow-up information.Conclusion With Radiotherapy Information System,the management of radiotherapy information becomes more systematic and standardized.

4.
Chinese Medical Equipment Journal ; (6)1989.
Artículo en Chino | WPRIM | ID: wpr-588361

RESUMEN

CT laser simulation positioning system is a necessary auxiliary device for radiotherapy. Its main purpose is to position patients by simulating different kinds of treatment machine. In order to demarcate the mark of the iso-center, it is common to use the laser positioning device to indicate the iso-center. The kernel technology of the laser positioning system is the controlling of the step progress motor by using the MCS, which is to control the movement of step progress motor using the wheel of the motor. This design uses MCS-51 to control step progress motor by the way of exporting the rectangle wave form through I/O port of 8255 chip. The system configuration is simple, the operation is convenient and the positioning is precise.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA