Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Añadir filtros








Intervalo de año
1.
International Eye Science ; (12): 1281-1283, 2014.
Artículo en Chino | WPRIM | ID: wpr-641973

RESUMEN

AlM: To measure ocular biometric values with the degree of axial myopia and determine the relationship between the differences using the Lenstar 900. METHODS:Totally 413 myopes (826 eyes) were enrolled in this study and were divided into 3 groups: low myopia (myopia 6. 00 diopters, 222 eyes ). Central corneal thickness ( CCT ) , aqueous depth ( AD ) , lens thickness (LT), axial length (AL) were measured by Lenstar 900. The parameters were tested using analysis of variance and the relations among SE, AL, LT were analyzed. RESULTS: There were significant difference both in AL (F=206.16, P CONCLUSlON: Along with the diopters increasing in myopia, the axial length and aqueous depth continue to increase. Spherical equivalent ( SE) shows a significantly positive correlation with AD. AL shows positive correlation with SE, AD and CCT and negative correlation with LT. LT shows a significantly negative correlation with AD.

2.
International Eye Science ; (12): 1440-1443, 2014.
Artículo en Chino | WPRIM | ID: wpr-641955

RESUMEN

AIM:To investigate the differences among Lenstar 900, A-scan ultrasound and keratometer in measurement of axial length ( AL ) , anterior chamber depth ( ACD ) and corneal curvature ( K1 , K2 , Km ) , and evaluate the consistency of the instruments, with the purpose providing references for the clinical application of Lenstar 900. METHODS: In this study we picked up 36 patients ( 50 eyes ) underwent cataract surgery, and lens nucleus hardness were under level IV. Before the operation, AL, ACD and K1 , K2 , Km were measured by Lenstar 900, A-scan ultrasound and keratometer respectively. The differences between the results were compared by the paired t-test. The correlation of the results was analyzed by Pearson correlation analysis, and the consistency was measured by Bland-Ahamn method. RESULTS: The mean AL and ACD values measured by Lenstar 900 and A-scan ultrasound had no significantly statistic differences (P>0. 05). The K1, K2, Km measured by Lenstar 900 and keratometer were not significantly statistical different (P>0. 05). The results measured by these three instruments had close linearity correlation ( r>0.9, P CONCLUSION:The preoperatively biometric result of Lenstar 900, A - scan ultrasound and keratometer in patients with cataract are all reliable, and they can be substituted by each other. However, Lenstar 900 can not only measure AL, ACD and corneal curvature at the same time, but also cornal thickness, lens thickness, white to white, pupil size, optical axis eccentricity, retinal thickness and so on. It has a number of advantages such as non-touching, convenient and efficient, and can be recommended to use widely.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA