Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
Braz. j. med. biol. res ; 51(3): e6540, 2018. tab, graf
Artículo en Inglés | LILACS | ID: biblio-889049

RESUMEN

The ideal feeding for premature babies has been the source of extensive debate. The aim of this study was to assess the association between type of feeding at discharge and the nutritional status of very low birth weight infants. This was a retrospective cohort of preterm babies with birth weight ≤1500 g, born between January 2006 and December 2013. The infants were divided into 3 groups according to type of feeding at discharge: exclusive breast milk (group 1), mixed feeding (group 2) and exclusive artificial formula (group 3). Frequencies of each group were calculated, as well as mean Z-score differences in weight, length and head circumference. Six hundred and forty-nine newborns were included. The mean weight of groups 1, 2, and 3 was 1338.7, 1104.0, and 1254.7 g, respectively, and their mean gestational age was 31.9, 30, and 31.2 weeks, respectively. The Z-score differences (means±SD) for groups 1, 2, and 3 were: −0.84±0.68, −1.02±0.75, and −0.86±0.71 for weight, −0.21±1.23, −0.52±1.64 and −0.08±1.34 for head circumference, and −1.10±1.18, −1.54±1.37, and −0.97±1.21 for length. A significant difference was observed between groups 2 and 3 in the adjusted Z-score model for length, with no significant differences in anthropometric measurements for the other comparative analyses. Because of its many advantages, breastfeeding should be stimulated within neonatal units since nutritional status was not influenced by the different types of feeding.


Asunto(s)
Humanos , Masculino , Femenino , Recién Nacido , Lactante , Lactancia Materna/estadística & datos numéricos , Fórmulas Infantiles/estadística & datos numéricos , Recien Nacido Prematuro/fisiología , Recién Nacido de muy Bajo Peso/fisiología , Estado Nutricional/fisiología , Alta del Paciente/estadística & datos numéricos , Estudios de Cohortes , Recién Nacido de muy Bajo Peso/crecimiento & desarrollo , Edad Materna , Estudios Retrospectivos , Aumento de Peso
2.
Braz. j. med. biol. res ; 47(3): 259-264, 03/2014. tab
Artículo en Inglés | LILACS | ID: lil-704627

RESUMEN

This study evaluated whether the use of continuous positive airway pressure (CPAP) in the delivery room alters the need for mechanical ventilation and surfactant during the first 5 days of life and modifies the incidence of respiratory morbidity and mortality during the hospital stay. The study was a multicenter randomized clinical trial conducted in five public university hospitals in Brazil, from June 2008 to December 2009. Participants were 197 infants with birth weight of 1000-1500 g and without major birth defects. They were treated according to the guidelines of the American Academy of Pediatrics (APP). Infants not intubated or extubated less than 15 min after birth were randomized for two treatments, routine or CPAP, and were followed until hospital discharge. The routine (n=99) and CPAP (n=98) infants studied presented no statistically significant differences regarding birth characteristics, complications during the prenatal period, the need for mechanical ventilation during the first 5 days of life (19.2 vs 23.4%, P=0.50), use of surfactant (18.2 vs 17.3% P=0.92), or respiratory morbidity and mortality until discharge. The CPAP group required a greater number of doses of surfactant (1.5 vs 1.0, P=0.02). When CPAP was applied to the routine group, it was installed within a median time of 30 min. We found that CPAP applied less than 15 min after birth was not able to reduce the need for ventilator support and was associated with a higher number of doses of surfactant when compared to CPAP applied as clinically indicated within a median time of 30 min.


Asunto(s)
Femenino , Humanos , Recién Nacido , Masculino , Embarazo , Presión de las Vías Aéreas Positiva Contínua , Salas de Parto , Recién Nacido de muy Bajo Peso/fisiología , Surfactantes Pulmonares/uso terapéutico , Síndrome de Dificultad Respiratoria del Recién Nacido/prevención & control , Extubación Traqueal , Brasil , Mortalidad Hospitalaria , Hipertensión/diagnóstico , Intubación Intratraqueal , Tiempo de Internación , Bienestar Materno , Diagnóstico Prenatal , Respiración Artificial
3.
Braz. j. med. biol. res ; 46(10): 892-896, 24/set. 2013. tab
Artículo en Inglés | LILACS | ID: lil-688560

RESUMEN

The objective of this study was to determine the feasibility of the use of continuous positive airway pressure installed prophylactically in the delivery room (DR-CPAP), for infants with a birth weight between 500 and 1000 g in settings with limited resources. During 23 months, infants with a birth weight between 500 and 1000 g consecutively received DR-CPAP. A total of 33 infants with low birth weight were enrolled, 16 (48.5%) were females. Only 14 (42.4%) received antenatal corticosteroids and only 2 of those 14 (14.3%) infants weighing 500-750 g were not intubated in the delivery room, and apnea was given as the reason for intubation of these patients. Of the 19 infants in the 751-1000 g weight range, 9 (47.4%) were intubated in the delivery room, 6 due to apnea and 3 due to respiratory discomfort. For DR-CPAP to be successful, it is probably necessary for preterm babies to be more prepared at birth to withstand the respiratory effort without the need for intubation. Antenatal corticosteroids and better prenatal monitoring are fundamental for success of DR-CPAP.


Asunto(s)
Femenino , Humanos , Recién Nacido , Masculino , Presión de las Vías Aéreas Positiva Contínua , Recién Nacido de muy Bajo Peso , Síndrome de Dificultad Respiratoria del Recién Nacido/terapia , Brasil , Salas de Parto , Países en Desarrollo , Estudios de Factibilidad , Recien Nacido Prematuro
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA