1.
Indian J Cancer ; 2014 Jul-Sep; 51(3): 366-368
Artículo en Inglés | IMSEAR | ID: sea-154421

RESUMEN

Treatment of cancer is limited by affordability of patients in the many developing countries including India. Generic drug manufacturers have responded to this scenario by making drugs available at affordable costs, often at less than 10% the cost of the original brand. In our practice, it is found that there is a three-fold higher prescription of generic brands compared to innovator, accompanied by cost savings of up to 80% per prescription. Unfortunately, the regulatory environment prevailing in India is not geared to ensure satisfactory quality of generic products. The standards set by the regulatory agencies for establishing equivalence of generics vis-ΰ-vis the innovator product allow anticancer generics to enter markets without undergoing clinical evaluation. Many drug manufacturing units in India flout good manufacturing practice norms, which was evident during the center for drug evaluation and research classifications inspection in the year 2006. Inferior drugs have therefore, made their way into the Indian markets, compromising the quality of care. The system of drug manufacturing and marketing approval needs a major overhaul, including regular inspection of manufacturing facilities. Bioequivalence should be made mandatory for all oral formulations. Unless these measures are rigidly implemented, the benefits of generic substitution would be seriously undermined.


Asunto(s)
Antineoplásicos/uso terapéutico , Medicamentos Genéricos/uso terapéutico , Humanos , India , Neoplasias/tratamiento farmacológico , Equivalencia Terapéutica
2.
Indian J Cancer ; 2009 Jul-Sept; 46(3): 237-239
Artículo en Inglés | IMSEAR | ID: sea-144246

RESUMEN

Occurrence of primary Hodgkin's lymphoma (PHL) of the liver is extremely rare. We report on a case of a 60-year-old male who presented with liver mass and B-symptomatology. Hepatoma or hepatic metastasis from a gastrointestinal primary was initially suspected. Tumor markers like AFP, CEA, Total PSA, and CA-19.9 were within normal limits. Positron Emission Tomography / Computerized Tomography (PET/CT) revealed a large hepatic lesion and a nodal mass in the porta hepatis. A liver biopsy was consistent with Hodgkin's lymphoma. There was complete regression of the hepatic lesion and evidence of shrinkage of the nodal mass following four cycles of chemotherapy. 18F Fluro -de-oxy Glucose (FDG) PET / CT in this case helped in establishing a primary hepatic lymphoma by demonstrating the absence of pathologically hypermetabolic foci in any other nodes or organs. PET / CT scan is a useful adjunct to conventional imaging and histopathology, not only to establish the initial diagnosis, but also to monitor treatment response in PHL.


Asunto(s)
Protocolos de Quimioterapia Combinada Antineoplásica/uso terapéutico , Fluorodesoxiglucosa F18/diagnóstico , Enfermedad de Hodgkin/tratamiento farmacológico , Enfermedad de Hodgkin/patología , Humanos , Neoplasias Hepáticas/tratamiento farmacológico , Neoplasias Hepáticas/patología , Masculino , Persona de Mediana Edad , Tomografía de Emisión de Positrones , Pronóstico , Radiofármacos/diagnóstico , Tomografía Computarizada por Rayos X