J. bras. pneumol ; 37(1): 61-68, jan.-fev. 2011. ilus, tab
Artículo en Portugués | LILACS | ID: lil-576114

RESUMEN

OBJETIVO: Determinar a concordância da medida da resistência das vias aéreas (RVA) pela técnica interrupter resistance (Rint, resistência do interruptor) com a do método pletismográfico para fins de aplicabilidade clínica. MÉTODOS: A técnica Rint foi realizada com os pacientes em posição sentada, em expiração, utilizando clipe nasal e com suporte das bochechas. O exame pletismográfico foi realizado de acordo com protocolos padronizados. As medidas foram realizadas antes e após a administração inalatória de um broncodilatador via spray dosimetrado com espaçador. RESULTADOS: Avaliamos 99 pacientes consecutivos encaminhados para o Hospital de Clínicas de Porto Alegre, Porto Alegre (RS), para a realização de testes de função pulmonar, com idades entre 18 e 82 anos. Desses, 52 eram mulheres. Houve boa concordância entre os métodos (r = 0,8; coeficiente de correlação intraclasse = 0,8) nos pacientes com VEF1 > 60 por cento do previsto. Os valores de Rint foram menores que os da RVA por pletismografia em indivíduos mais graves. Entretanto, houve boa concordância entre Rint > 4 cmH2O • L-1 • s-1 e RVA por pletismografia > 2,5 cmH2O • L-1 • s-1 (razão de verossimilhança > 8 e coeficiente kappa = 0,73). CONCLUSÕES: A concordância entre o Rint e a RVA por pletismografia foi boa nos indivíduos menos graves. A concordância para um diagnóstico de aumento da RVA entre os dois métodos também foi forte. A técnica Rint é um método potencialmente útil na prática assistencial em adultos.


OBJECTIVE: To determine the agreement between interrupter resistance (Rint) and airway resistance (Raw) by plethysmography in order to verify the clinical applicability of the interrupter technique. METHODS: The Rint technique was performed with the patients in a sitting position, during exhalation, with a nose clip and cheek support. Plethysmography was carried out in accordance with standard protocols. All measurements were taken prior to and after the administration of an inhaled bronchodilator via a metered dose inhaler with a spacer. RESULTS: The study comprised 99 consecutive patients referred to the Porto Alegre Hospital de Clínicas, located in the city of Porto Alegre, Brazil, for pulmonary function testing. Patient ages ranged from 18 to 82 years, and 52 of the patients were women. In the patients with FEV1 > 60 percent of predicted, there was good agreement between the methods (r = 0.8; intraclass correlation coefficient = 0.8). The Rint values were lower than were those of Raw by plethysmography in the patients with more severe disease. However, there was good agreement between Rint > 4 cmH2O • L-1• s-1 and Raw by plethysmography > 2.5 cmH2O • L-1 • s-1 (likelihood ratio > 8; kappa coefficient = 0.73). CONCLUSIONS: In the patients with less severe disease, there was good agreement between Rint and Raw by plethysmography. The agreement between the two methods was also strong regarding the detection of an increase in Raw. The Rint technique is a potentially useful method for the evaluation of adult patients.


Asunto(s)
Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Adulto Joven , Obstrucción de las Vías Aéreas/diagnóstico , Resistencia de las Vías Respiratorias/fisiología , Pruebas de Función Respiratoria/métodos , Obstrucción de las Vías Aéreas/fisiopatología , Brasil , Pletismografía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA