Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Añadir filtros








Intervalo de año
1.
Rev. bras. cir. cardiovasc ; 24(2): 194-199, abr.-jun. 2009. ilus, tab
Artículo en Inglés, Portugués | LILACS | ID: lil-525551

RESUMEN

OBJETIVO: Avaliar a evolução de pacientes de alto risco submetidos a aortoplastia redutora com contenção externa associada a troca valvar aórtica. MÉTODOS: Seis pacientes portadores de aneurisma de aorta ascendente e valvopatia aórtica, sendo quatro do sexo masculino, foram incluídos no estudo. Um paciente apresentava insuficiência mitral importante. A idade variou de 61 a 70 anos (média de 65,7 anos). A insuficiência aórtica foi a indicação de troca valvar em 83,3 por cento dos pacientes e a estenose aórtica, em 16,7 por cento. Os critérios de inclusão foram: pacientes portadores de valvopatia aórtica com indicação cirúrgica, aorta ascendente com diâmetro > 5,5 cm, EuroSCORE > 6 e idade acima de 60 anos. O diâmetro da aorta ascendente variou de 57 a 68 mm (média de 63,7 mm). Análise estatística foi realizada utilizando o teste t pareado para as variáveis estudadas, com nível de significância menor que 5 por cento. RESULTADOS: Todos os pacientes foram submetidos a aortoplastia redutora com contenção externa associada a troca valvar aórtica. Não houve mortalidade hospitalar na série estudada. Um (16,7 por cento) paciente apresentou fibrilação atrial no pós-operatório. O diâmetro médio da aorta ascendente foi de 37,0 +4,5 mm aos 6 meses de pós-operatório (P < 0,0001, em relação ao pré-operatório). A curva atuarial de sobrevivência é de 100 por cento ao final de 28 meses de seguimento. CONCLUSÃO: A aortoplastia redutora associada a contenção externa e troca valvar aórtica é uma opção terapêutica com resultados promissores a médio prazo, em pacientes de alto risco cirúrgico portadores de aneurisma de aorta ascendente e valvopatia aórtica.


OBJECTIVE: To assess the midterm follow-up of reduction aortoplasty with external wrapping associated with aortic valve replacement in high risk patients. METHODS: Six patients with ascending aortic aneurysm and aortic valve disease were included in this study. Four of them were male. The age ranged from 61 to 70 years (mean 65.7 years). One patient presented severe mitral valve insufficiency. All patients underwent aortic valve replacement (83.3 percent with aortic insufficiency and 16.7 percent with aortic stenosis). The inclusion criteria were: surgical aortic valve disease, ascending aortic aneurysm > 5.5 cm, EuroSCORE > 6 and age above 60 years. The ascending aortic diameter ranged from 57 to 68 mm (mean 63.7 mm). Data were analyzed by paired T test for comparison between the studied variables and P < 0.05 was considered significant. RESULTS: All patients underwent reduction aortoplasty with external wrapping associated with aortic valve replacement. The postoperative hospital mortality and morbidity was 0 percent and 16.7 percent (atrial fibrillation), respectively. The mean ascending aortic diameter was 37.0 + 4.5mm after 6 months of follow-up (P < 0.0001, compared with the preoperative period). The actuarial survival curve after 28 months of follow-up was 100 percent. CONCLUSION: Reduction ascending aortoplasty with external wrapping associated with aortic valve replacement is a safe procedure with excellent midterm results in high risk patients with ascending aortic aneurysm and aortic valve disease.


Asunto(s)
Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Aorta/cirugía , Aneurisma de la Aorta/cirugía , Insuficiencia de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Aorta/patología , Métodos Epidemiológicos , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA