Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
An. bras. dermatol ; 90(3,supl.1): 175-177, May-June 2015. ilus
Artículo en Inglés | LILACS | ID: lil-755772

RESUMEN

Abstract

Palmoplantar lichen planus is an uncommon dermatosis. We present a case of 38-year-old Caucasian male with a history of pruritic, scaly lesions on the right plantar foot. Physical examination revealed whitish plaques and numerous spiny hyperkeratotic papules and focal scaling. A biopsy demonstrated orthohyperkeratosis and acanthosis of the epidermis. Immunohistochemical staining revealed positivity within the epidermis and/or lichenoid infiltrate with CD3, CD8, CD45, CD68, myeloid histiod antigen, BCL2, p27, p53, HLA-DPDQDR, metallothionein and tissue inhibitor of metalloproteinases 1. The diagnosis of PPLP was thus confirmed; this case illustrates that PPLP should be considered in the differential diagnosis of uncommon foot dermatoses with a significant junctional inflammatory component.

.


Asunto(s)
Adulto , Humanos , Masculino , Dermatosis del Pie/patología , Dermatosis de la Mano/patología , Liquen Plano/patología , Biopsia , Diagnóstico Diferencial , Epidermis/patología , Inmunohistoquímica
2.
Rev. chil. cardiol ; 34(1): 28-35, abr. 2015. ilus, tab, graf
Artículo en Español | LILACS | ID: lil-749425

RESUMEN

Introducción: Para el reemplazo de válvula aórtica con catéteres (TAVR) es fundamental la adecuada medición del anillo aórtico para elegir el tamaño adecuado de la prótesis y evitar complicaciones graves como la ruptura del anillo aórtico y la insuficiencia paravalvular (IAP). La tomografía computada cardíaca (TC) es el estándar de oro en la medición del anillo aórtico, pero la ecocardiografía transesofágica 3D (ETE3D) parece ser una alternativa atractiva. Objetivo: Evaluar la correlación entre las mediciones del anillo aórtico obtenidas por ETE3D y las encontradas en la TC. Los resultados obtenidos se evaluaron en términos de la prótesis elegida y la presencia de insuficiencia aórtica post TAVR. Métodos: Se realizaron de manera retrospectiva y ciega, las mediciones del anillo aórtico por TC y ETE3D en 18 pacientes consecutivos, edad promedio 82 ± 7,06 años, sometidos a TAVR usando prótesis Sapien XT (Edwards Lifescience). Se comparó el diámetro máximo, diámetro mínimo, diámetro medio, área y perímetro del anillo. Resultados: La ETE3D subvaloró el tamaño del anillo aórtico, pero demostró tener una buena correlación con los diferentes parámetros de la TC, con mejor comportamiento para el perímetro del anillo. ETE3D y TC coincidieron en la elección de la prótesis en 17 pacientes y no hubo IAP de relevancia. Conclusión: La ETE3D tiene buena correlación comparada contra la TC en la valoración del anillo aórtico. La ETE3D parece una atractiva alternativa a la TC para medición del anillo especialmente en casos complejos o cuando la disponibilidad y acceso a la TC puede estar limitada.


In TAVR, the precise measuring of the aortic annulus is essential to determine the size of the prosthesis and to avoid complications like rupture of the annulus of aortic insufficiency. Computed tomography (CT) is the gold standard to achieve these goals. 3-D trans-esophageal echocardiography (3-D TEE) to be a useful alternative method. Aim: to evaluate the correlation of aortic annulus measurements obtained with 3-dTE and CT in the determination of annulus measurements before TAVR. Prosthesis size and presence of aortic insufficiency were related to these measurements. Methods: In a retrospective blinded protocol the measurements of the aortic annulus obtained with CT or 3D-TEE were correlated in 18 consecutive patients (mean age 82 ± 7.1) submitted to TAVR with a Sapien XT (Edwards Lifescience) prosthesis. Maximal, minimal and mean diameters as well as area and annular circumference were evaluated. Results: Compared to CT, 3D-TEE under estimated de size of the aortic annulus but correlated well with other measurements of CT, especially with the annular circumference. Measurements from both methods agreed in the determination of the prosthesis size in 17 of 18 patients. No significant per prosthetic aortic insufficiency was observed in any case. Conclusion: 3DTEE correlates well with CT in evaluating the different parameters of the aortic annulus and is a good alternative to CT in complex cases and when CT is not readily available.


Asunto(s)
Humanos , Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Ecocardiografía Transesofágica/métodos , Ecocardiografía Tridimensional/métodos , Tomografía Computarizada Multidetector/métodos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Estenosis de la Válvula Aórtica/terapia , Diseño de Prótesis , Cuidados Preoperatorios , Estudios Retrospectivos
3.
Rev. chil. cardiol ; 17(2): 84-91, abr.-jun. 1998. tab, graf
Artículo en Español | LILACS | ID: lil-231649

RESUMEN

La disección aguda de la aorta ascendente (DAAA) constituye una patología con cifras de mortalidad que alcanzan al 25 por ciento a 24 hrs y más del 50 por ciento a la semana. La reparación quirúrgica precoz es la única alternativa de tratamiento eficaz. Sin embargo, su morbimortalidad continúa siendo elevada. En los últimos años ésta ha disminuido por la introducción de nuevas técnicas quirúrgicas y de manejo intraoperatorio. Entre 1985 y junio de 1997 operamos 65 pacientes (pts) con DAAA, 45 hombres (70 por ciento), edad promedio 52,2 ñ 13,1 años. Un 66 por ciento eran hipertensos y 14 por ciento tenían Síndrome de Marfán. El dolor fue el síntoma de presentación en 94 por ciento y un tercio de los pts se presentó con insuficiencia aórlica masiva o taponamiento en shock cardiogénico. Como examen diagnóstico se utilizó el TAC en 36 pts, angiografía en 27, ecocardiograma de superficie en 40 y transesofágico en 29. La localización más frecuente de la ruptura intimal fue la aorta ascendente (75 por ciento). Un 72 por ciento de los pts fueron operados con menos de 24 h de evolución. En 37pts se utilizó el paro circulatorio en hipotermia profunda y en 28 se asoció perfusión cerebral retrógrada. Los tiempos promedio de CEC, clampeo aótico y paro circulatotio fueron 170, 96 y 40 m, respectivamente. En todos los pts se reemplazó la aorta ascendente, además el arco proximal en 3. En 11 se utilizó un tubo compuesto. En 9 se efectuó RVA y suspensión de velos en 22. En 5 se agregó bypass coronario y en 15 se reimplantó uno o ambos ostium coronarios. La mortalidad operatoria global fue 24 por ciento (16/65). Desde 1995 ha disminuido a 12 por ciento (2/16). Las complicaciones post operatorias fueron: sangramiento 12, IRA y diálisis 3 y AVE en 3 pts. Se completó el seguimiento a un 97 por ciento de los pts con un promedio de 35 meses; tres pts fallecen de progresión de su enfermedad aneurismática y 7 de otras causas. La sobrevida actuarial a 5 años fue de 78 por ciento. En conclusión: nuevas técnicas quirúrgicas y de manejo intraoperatorio sumado a la experiencia acumulada, han permitido disminuir la morbimortalidad perioperatoria en la DAAA y ofrecer adecuada sobrevida a mediano plazo


Asunto(s)
Humanos , Masculino , Femenino , Adulto , Persona de Mediana Edad , Procedimientos Quirúrgicos Cardiovasculares , Rotura de la Aorta/cirugía , Supervivencia sin Enfermedad , Insuficiencia de la Válvula Aórtica/etiología , Síndrome de Marfan , Complicaciones Posoperatorias , Estudios Retrospectivos , Rotura de la Aorta/complicaciones , Rotura de la Aorta/diagnóstico , Choque Cardiogénico/etiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA