Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Annals of Surgical Treatment and Research ; : 117-124, 2022.
Artículo en Inglés | WPRIM | ID: wpr-913524

RESUMEN

Purpose@#This study was performed To investigate the use of hydrophilic guidewires for facilitating catheter advancement during varicose vein treatment using radiofrequency ablation (RFA) or cyanoacrylate closure (CAC). @*Methods@#From March 2016 to April 2019, 463 limbs of 285 with incompetent great saphenous veins were subjected to RFA (321 limbs of 197 patients) or CAC (142 limbs of 88 patients). Procedure records were reviewed for the use of a hydrophilic guidewire, reason for the guidewire usage, and diameter of the guidewire. @*Results@#A hydrophilic guidewire was used to facilitate catheter advancement to treat 92 of 463 limbs (19.9%). For RFA, a guidewire was used to treat 53 of 321 limbs (16.5%). Among them, 15 limbs (28.3%) had vasospasm, and 38 limbs (71.7%) had venous tortuosity. For CAC, guidewire was used for 39 of 142 limbs (27.5%). Among them, 10 limbs (25.6%) had vasospasm, 23 limbs (59.0%) had venous tortuosity, and 6 limbs (15.4%) had repeated engagement of a J-tip guidewire into the varicose tributaries. In CAC, the frequency of hydrophilic guidewire usage was higher than that in RFA (P = 0.006). All varicose vein treatment sessions were technically successful. @*Conclusion@#Hydrophilic guidewire usage could facilitate catheter advancement when hindered by vasospasm, tortuosity of the saphenous vein, or repeated engagement into the varicose tributaries.

2.
Korean Journal of Radiology ; : 224-229, 2016.
Artículo en Inglés | WPRIM | ID: wpr-44155

RESUMEN

OBJECTIVE: To evaluate the efficacy and safety of balloon-occluded retrograde transvenous obliteration (BRTO) with sodium tetradecyl sulfate (STS) liquid sclerotherapy of gastric varices. MATERIALS AND METHODS: Between February 2012 and August 2014, STS liquid sclerotherapy was performed in 17 consecutive patients (male:female = 8:9; mean age 58.6 years, range 44-86 years) with gastric varices. Retrograde venography was performed after occlusion of the gastrorenal shunt using a balloon catheter and embolization of collateral draining veins using coils or gelfoam pledgets, to evaluate the anatomy of the gastric varices. We prepared 2% liquid STS by mixing 3% STS and contrast media in a ratio of 2:1. A 2% STS solution was injected into the gastric varices until minimal filling of the afferent portal vein branch was observed (mean 19.9 mL, range 6-33 mL). Patients were followed up using computed tomography (CT) or endoscopy. RESULTS: Technical success was achieved in 16 of 17 patients (94.1%). The procedure failed in one patient because the shunt could not be occluded due to the large diameter of gastrorenal shunt. Complete obliteration of gastric varices was observed in 15 of 16 patients (93.8%) with follow-up CT or endoscopy. There was no rebleeding after the procedure. There was no procedure-related mortality. CONCLUSION: BRTO using STS liquid can be a safe and useful treatment option in patients with gastric varices.


Asunto(s)
Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Oclusión con Balón , Medios de Contraste/química , Demografía , Embolización Terapéutica , Endoscopía del Sistema Digestivo , Várices Esofágicas y Gástricas/terapia , Estudios de Seguimiento , Vena Porta/diagnóstico por imagen , Escleroterapia , Tetradecil Sulfato de Sodio/química , Tomografía Computarizada por Rayos X
3.
Annals of Surgical Treatment and Research ; : 41-43, 2014.
Artículo en Inglés | WPRIM | ID: wpr-112284

RESUMEN

Intraperitoneal bleeding after radiofrequency ablation (RFA) is the most common major vascular complication due to direct needle injury to a vessel or liver capsule. However, intraperitoneal bleeding as a result of a delayed hepatic rupture after RFA for liver tumors is an extremely rare complication. The present report describes a case of intraperitoneal hemorrhage caused by delayed hepatic rupture resulting from arterioportal fistula after RFA for hepatic metastasis from colorectal cancer and successful management using transcatheter embolization.


Asunto(s)
Ablación por Catéter , Neoplasias Colorrectales , Embolización Terapéutica , Fístula , Hemorragia , Hígado , Agujas , Metástasis de la Neoplasia , Tratamiento de Radiofrecuencia Pulsada , Rotura
4.
Korean Journal of Radiology ; : 481-487, 2014.
Artículo en Inglés | WPRIM | ID: wpr-9202

RESUMEN

OBJECTIVE: To compare the efficacy and adverse effects of endovenous foam sclerotherapy (EFS) and liquid sclerotherapy (ELS) using a microcatheter for the treatment of varicose tributaries. MATERIALS AND METHODS: From December 2007 to January 2009, patients with venous reflux in the saphenous vein were enrolled. The foam or liquid sclerosant was injected through a microcatheter just before endovenous laser ablation (EVLA). Patients were evaluated for the technical success, clinical success, and procedure-related complications during the procedure and follow-up visits. RESULTS: A total of 94 limbs were included: 48 limbs (great saphenous vein [GSV], 35; small saphenous vein [SSV], 13) were managed using EFS and EVLA (foam group; FG), and 46 limbs (GSV, 37; SSV, 9) were treated by ELS and EVLA (liquid group; LG). Varicose tributaries demonstrated complete sclerosis in 92.7% with FG and in 71.8% with LG (p = 0.014). Bruising (78.7% in FG vs. 73.2% in LG, p > 0.05), pain or tenderness (75.6% in FG vs. 51.2% in LG, p = 0.0237) were noted. Hyperpigmentation (51.2% in FG vs. 46.2% in LG, p > 0.05) was found. CONCLUSION: Endovenous foam sclerotherapy using a microcatheter is more effective than ELS for eliminating remnant varicose tributaries prior to EVLA. However, EFS is more commonly associated with local complications such as pain or tenderness than ELS. Furthermore, both techniques seem to prolong the duration of hyperpigmentation along with higher costs.


Asunto(s)
Humanos , Catéteres/efectos adversos , Vena Femoral , Fluoroscopía/métodos , Terapia por Láser/métodos , Radiografía Intervencional/métodos , Vena Safena/diagnóstico por imagen , Soluciones Esclerosantes/administración & dosificación , Escleroterapia/efectos adversos , Resultado del Tratamiento , Várices/diagnóstico por imagen , Insuficiencia Venosa/cirugía
5.
Korean Journal of Radiology ; : 467-475, 2012.
Artículo en Inglés | WPRIM | ID: wpr-72927

RESUMEN

OBJECTIVE: To evaluate the efficacy of various strategies for revascularization of chronic total occlusion of femoropopliteal arteries when the guide wire does not pass in an anterograde direction. MATERIALS AND METHODS: Twenty-four patients with totally occluded femoropopliteal arteries (mean occlusion length 13.75 cm; range, 6-22 cm) were treated by using a retrograde approach and two novel catheters. After successful recanalization or reentry, balloon angioplasty followed by stent placement was performed to complete the revascularization. RESULTS: In 16 cases in which to cross the occlusion via intraluminal or subintimal route was failed, we used Frontrunner catheters in five cases and Outback catheters in 11 cases. In eight cases in which to reenter after subintimal passage of the guide wire was failed, we used Outback catheters. Successful recanalization was achieved intraluminally or subintimally in all cases. One perforation occurred during subintimal passage of the guide wire that was controlled by recanalization of another subintimal tract. There were no cases of distal thromboembolism or other complications. CONCLUSION: A retrograde approach and using the Frontrunner and Outback catheters are safe and effective for successful revascularization of chronic total occlusion of femoropopliteal arteries. In particular, they are useful when the initial antegrade attempts at recanalization have failed.


Asunto(s)
Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Angiografía , Angioplastia de Balón , Arteriopatías Oclusivas/diagnóstico por imagen , Cateterismo Periférico , Arteria Femoral , Arteria Poplítea , Estudios Prospectivos , Stents , Resultado del Tratamiento
6.
Korean Journal of Radiology ; : 481-486, 2011.
Artículo en Inglés | WPRIM | ID: wpr-34043

RESUMEN

OBJECTIVE: We wanted to evaluate the effectiveness of endovenous ablation of the incompetent vein of Giacomini using a 980-nm diode laser. MATERIALS AND METHODS: A total of 18 patients (18 limbs, 4%) had the incompetent vein of Giacomini. Retrograde reflux originating from the great saphenous vein was noted in sixteen limbs and paradoxical diastolic anterograde reflux from the saphenopopliteal junction was observed in two limbs. After tumescent anesthesia, laser ablation using a 980-nm wavelength laser fiber was performed under ultrasound and/or fluoroscopic guidance. Patients were evaluated clinically and with duplex ultrasound at one week and at one, three, six and twelve months after laser ablation for the technical and clinical success. RESULTS: In the 18 limbs, the technical success rate was 100%. Continued closure of the vein of Giacomini was seen in 18 of 18 limbs after one month, in 12 of 12 limbs after three and six months and in six of six limbs after twelve months. No recanalization of the vein and no major complications occurred. CONCLUSION: Endovenous laser ablation with a 980-nm wavelength is an effective and safe procedure for treating an incompetent vein of Giacomini.


Asunto(s)
Adulto , Femenino , Humanos , Masculino , Persona de Mediana Edad , Fluoroscopía , Terapia por Láser/métodos , Láseres de Semiconductores , Pierna/irrigación sanguínea , Vena Safena/cirugía , Resultado del Tratamiento , Insuficiencia Venosa/cirugía
7.
Korean Journal of Radiology ; : 107-112, 2011.
Artículo en Inglés | WPRIM | ID: wpr-36587

RESUMEN

OBJECTIVE: We wanted to evaluate the efficacy of stent placement using the coaxial technique with a stiff, long introducer sheath in patients with technical failure using an angiographic catheter for the obstructions proximal to the descending colon. MATERIALS AND METHODS: Self-expandable metallic stent placement was attempted under fluoroscopy-guidance in 77 consecutive patients who had malignant colorectal obstruction. Stent placement was performed using an angiographic catheter and a guide wire. If the angiographic catheter could not be advanced over the guide wire into the obstructive lesions proximal to the descending colon, then a 6-Fr introducer sheath was used. The technical success rate, the clinical success rate and the complications were analyzed. RESULTS: Successful stent placement was achieved in 75 of 77 patients (97%). The angiographic catheter failed to advance into the obstructive lesions of 11 patients (M:F = 7:4; mean age, 65.5 years) whose lesions were at the level of the splenic flexure or transverse colon. Therefore, the coaxial technique was implemented in all these 11 patients using a 6-Fr stiff introducer sheath and then the stent placement was successful. There were no complications related to the use of a stiff introducer sheath. Clinical success, which was defined as relief of clinical obstructive bowel symptoms, was obtained within 24 hours in all of patients. CONCLUSION: The coaxial technique using a stiff introducer sheath can increase the technical success of fluoroscopy-guided, self-expandable metallic stent placement in patients with colonic obstruction proximal to the descending colon.


Asunto(s)
Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Catéteres , Colon Descendente , Enfermedades del Colon/etiología , Neoplasias del Colon/complicaciones , Fluoroscopía , Obstrucción Intestinal/etiología , Radiografía Intervencional , Stents
8.
Korean Journal of Radiology ; : 203-209, 2011.
Artículo en Inglés | WPRIM | ID: wpr-73326

RESUMEN

OBJECTIVE: We wanted to evaluate the status of self-expandable nitinol stents implanted in the P2 and P3 segments of the popliteal artery in Korean patients. MATERIALS AND METHODS: We retrospectively analyzed 189 consecutive patients who underwent endovascular treatment for stenoocclusive lesions in the femoropopliteal artery from July 2003 to March 2009, and 18 patients who underwent stent placement in popliteal arterial P2 and P3 segments were finally enrolled. Lesion patency was evaluated by ultrasound or CT angiography, and stent fracture was assessed by plain X-rays at 1, 3, 6 and 12 months and annually thereafter. RESULTS: At the 1-month follow-up, stent fracture (Type 2) was seen in one limb (up to P3, 1 of 18, 6%) and it was identified in seven limbs at the 3-month follow-up (Type 2, Type 3, Type 4) (n = 1: up to P2; n = 6: P3). At the 6-month follow-up, one more fracture (Type 1) (up to P3) was noted. At the 1-year follow-up, there were no additional stent fractures. Just four limbs (up to P2) at the 2-year follow-up did not have stent fracture. The primary patency was 94%, 61% and 44% at 1, 3 and 6 months, respectively, and the group with stent implantation up to P3 had a higher fracture rate than that of the group that underwent stenting up to P2 (p < 0.05). CONCLUSION: We suggest that stent placement up to the popliteal arterial P3 segment and over P2 in an Asian population can worsen the stent patency owing to stent fracture. It may be necessary to develop a stent design and structure for the Asian population that can resist the bending force in the knee joint.


Asunto(s)
Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Aleaciones , Angiografía , Arteriopatías Oclusivas/diagnóstico por imagen , Distribución de Chi-Cuadrado , Fluoroscopía , Corea (Geográfico) , Pierna/irrigación sanguínea , Enfermedades Vasculares Periféricas/diagnóstico por imagen , Arteria Poplítea , Falla de Prótesis , Estudios Retrospectivos , Stents , Tomografía Computarizada por Rayos X , Ultrasonografía Doppler en Color , Ultrasonografía Doppler Dúplex , Grado de Desobstrucción Vascular
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA