Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Añadir filtros








Intervalo de año
1.
Korean Journal of Spine ; : 252-254, 2013.
Artículo en Inglés | WPRIM | ID: wpr-219671

RESUMEN

A 47-year-old woman visited with lumbago and severe left leg pain that had been presented for 1 week. The patient complained of severe radiating pain on left L3 sensory dermatome area and reported aggravation of leg pain at 20 degrees of hip flexion by straight leg raising test (SLRT). However, there was no motor weakness on neurological examination. Magnetic resonance imaging (MRI) demonstrated contrast enhancing spinal extradural mass at L2-3 level that was iso-signal intensity (SI) on T1-weighted images (WI), hypo-SI on T2WI. She was not able to walk and sleep due to incapacitating pain. Thus, surgical removal was performed via left partial laminectomy. Postoperatively, the radiating pain was relieved completely. Histopathologic examination revealed that the tumor consisted of chondroma, which had mature hyaline cartilage with nests of benign-appearing cells and calcium deposits in lacunae.


Asunto(s)
Femenino , Humanos , Persona de Mediana Edad , Calcio , Condroma , Cadera , Cartílago Hialino , Laminectomía , Pierna , Dolor de la Región Lumbar , Imagen por Resonancia Magnética , Examen Neurológico , Ciática
2.
Yonsei Medical Journal ; : 825-831, 2009.
Artículo en Inglés | WPRIM | ID: wpr-178453

RESUMEN

PURPOSE: The aim of this study was to evaluate the survival, proliferation, and bone formation of dog mesenchymal stem cells (dMSCs) in the graft material by using Polycaprolactone-tricalcium phosphate (PCL-TCP), auto-fibrin glue (AFG), recombinant human bone morphogenetic protein-2 (rhBMP-2), and dMSCs after a transplantation to the scapula of adult beagle dogs. MATERIALS AND METHODS: The subjects were two beagle dogs. Total dose of rhBMP-2 on each block was 10 microg with 50 microg/mg concentration. The cortical bone of the scapula of the dog was removed which was the same size of PCL-TCP block (Osteopore International Pte, Singapore; 5.0x5.0x8.0 mm in size), and the following graft material then was fixed with orthodontic mini-implant, Dual-top(R) (Titanium alloy, Jeil Co. Seoul, Korea). Four experimental groups were prepared for this study, Group 1: PCL-TCP + aFG; Group 2: PCL-TCP + aFG + dMSCs; Group 3: PCL-TCP + aFG + dMSCs + rhBMP-2; Group 4: PCL-TCP + aFG + dMSCs + rhBMP-2 + PCL membrane. The survival or proliferation of dMSCs cells was identified with an extracted tissue through a fluorescence microscope, H-E staining and Von-Kossa staining in two weeks and four weeks after the transplantation. RESULTS: The survival and proliferation of dMSCs were identified through a fluorescence microscope from both Group 1 and Group 2 in two weeks and four weeks after the transplantation. Histological observation also found that the injected cells were proliferating well in the G2, G3, and G4 scaffolds. CONCLUSION: This study concluded that bone ingrowth occurred in PCL-TCP scaffold which was transplanted with rhBMP-2, and MSCs did not affect bone growth. More sufficient healing time would be needed to recognize effects of dMSCs on bone formation.


Asunto(s)
Animales , Perros , Humanos , Proteínas Morfogenéticas Óseas/farmacología , Fosfatos de Calcio/farmacología , Proliferación Celular/efectos de los fármacos , Supervivencia Celular/efectos de los fármacos , Células Cultivadas , Adhesivo de Tejido de Fibrina/farmacología , Trasplante de Células Madre Mesenquimatosas , Células Madre Mesenquimatosas/citología , Microscopía Fluorescente , Osteogénesis/efectos de los fármacos , Poliésteres/farmacología , Proteínas Recombinantes/farmacología , Factor de Crecimiento Transformador beta/farmacología
3.
The Journal of Advanced Prosthodontics ; : 31-36, 2009.
Artículo en Inglés | WPRIM | ID: wpr-111185

RESUMEN

PURPOSE: To determine the change in stability of single-stage, three different design of implant systems in humans utilizing resonance frequency analysis for early healing period (24 weeks), without loading. MATERIAL AND METHODS: Twenty-five patients were included into this study. A total of 45 implants, three different design of implant systems (group A,C,R) were placed in the posterior maxilla or mandible. The specific transducer for each implant system was used. ISQ (implant stability quotient) reading were obtained for each implant at the time of surgery, 3, 6, 8, 10, 12, 24 weeks postoperatively. Data were analyzed for different implant type, bone type, healing time, anatomical locations. RESULTS: For each implant system, a two-factor mixed-model ANOVA demonstrated that a significant effect on ISQ values (group A = 0.0022, C = 0.017, R = 0.0018). For each implant system, in a two-factor mixed model ANOVA, and two-sample t-test, the main effect of jaw position (P > .005) on ISQ values were not significant. CONCLUSIONS: All the implant groups A, C and R, the change patterns of ISQ over time differed by bone type. Implant stability increased greatly between week 0 and week six and showed slow increase between week six and six months (plateau effect).


Asunto(s)
Humanos , Maxilares , Mandíbula , Maxilar , Oseointegración , Transductores
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA