Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 56
Filtrar
1.
Soonchunhyang Medical Science ; : 7-10, 2020.
Artículo | WPRIM | ID: wpr-837190

RESUMEN

The following report describes the occurrence of severe hypotension and bradycardia in a healthy 50-year-old man following placement from supine to the beach chair position during general anesthesia for injured rotator cuff tendon repair, as well as the occurrence of micturition syncope in a 71-year-old man following postobstructive diuresis after combined spinal–epidural anesthesia for total knee replacement. Rapid decompression of the urinary bladder is associated with severe hypotension, bradycardia, and syncope. Neurally mediated syncope includes true vasovagal and situational syncope that can occur in association with various situations such as cough, micturition, postprandial state, and interscalene block. We report two cases of neurally mediated syncope (true vasovagal and situational) that occurred in different conditions and were controlled well with prompt and proper management without serious complications.

2.
Korean Journal of Anesthesiology ; : 479-485, 2019.
Artículo en Inglés | WPRIM | ID: wpr-759564

RESUMEN

BACKGROUND: Ultrasound-guided greater occipital nerve (GON) block has been frequently used to treat various types of headaches, and botulinum toxin has recently begun to be used in patients with headache. Our study presents the long-term effect of botulinum toxin on GON block using ultrasound in patients with chronic headache in occipital area. METHODS: Patients with occipital headache were divided into two groups (bupivacaine: BUP group [n = 27], botulinum toxin: BTX group [n = 27]), and ultrasound-guided GON block was performed at the C2 level. GON was detected with ultrasound and distance from GON to midline, from the skin surface to GON, and size of GON were measured in both groups. Visual analogue scale (VAS) scores and Likert scale were assessed at pretreatment and at 1, 4, 8, and 24 weeks after treatment in both groups. RESULTS: The distance from GON to midline was 18.9 ± 4.4 mm (right) and 17.3 ± 3.8 mm (left). The depth from the skin was 12.9 ± 1.5 mm (right) and 13.4 ± 1.6 mm (left). GON size was 3.1 mm on both sides. The VAS score and patient satisfaction score (Likert scale) in 4, 8, and 24 weeks after injection were superior for the BTX than the BUP group. CONCLUSIONS: Ultrasound-guided GON block using BTX is effective in reducing short-term and long-term pain in patients with chronic headache in the occipital area.


Asunto(s)
Humanos , Toxinas Botulínicas , Cefalea , Trastornos de Cefalalgia , Bloqueo Nervioso , Satisfacción del Paciente , Piel , Ultrasonografía
3.
Korean Journal of Anesthesiology ; : 479-485, 2019.
Artículo en Inglés | WPRIM | ID: wpr-917497

RESUMEN

BACKGROUND@#Ultrasound-guided greater occipital nerve (GON) block has been frequently used to treat various types of headaches, and botulinum toxin has recently begun to be used in patients with headache. Our study presents the long-term effect of botulinum toxin on GON block using ultrasound in patients with chronic headache in occipital area.@*METHODS@#Patients with occipital headache were divided into two groups (bupivacaine: BUP group [n = 27], botulinum toxin: BTX group [n = 27]), and ultrasound-guided GON block was performed at the C2 level. GON was detected with ultrasound and distance from GON to midline, from the skin surface to GON, and size of GON were measured in both groups. Visual analogue scale (VAS) scores and Likert scale were assessed at pretreatment and at 1, 4, 8, and 24 weeks after treatment in both groups.@*RESULTS@#The distance from GON to midline was 18.9 ± 4.4 mm (right) and 17.3 ± 3.8 mm (left). The depth from the skin was 12.9 ± 1.5 mm (right) and 13.4 ± 1.6 mm (left). GON size was 3.1 mm on both sides. The VAS score and patient satisfaction score (Likert scale) in 4, 8, and 24 weeks after injection were superior for the BTX than the BUP group.@*CONCLUSIONS@#Ultrasound-guided GON block using BTX is effective in reducing short-term and long-term pain in patients with chronic headache in the occipital area.

4.
The Korean Journal of Pain ; : 116-125, 2017.
Artículo en Inglés | WPRIM | ID: wpr-192935

RESUMEN

BACKGROUND: Spinal pain is most common symptom in pain clinic. In most cases, before the treatment of spinal pain, physician explains the patient's disease and treatment. We investigated patient's satisfaction and physician's explanation related to treatments in spinal pain patients by questionnaires. METHODS: Anonymous questionnaires about physician's explanation and patient's satisfaction in each treatment and post-treatment management were asked to individuals suffering from spinal pain. Patients who have spinal pain were participated in our survey of nationwide university hospitals in Korea. The relationships between patient's satisfaction and other factors were analyzed. RESULTS: Between June 2016 and August 2016, 1007 patients in 37 university hospitals completed the questionnaire. In the statistical analysis, patient's satisfaction of treatment increased when pain severity was low or received sufficient preceding explanation about nerve block and medication (P < 0.01). Sufficient explanation increased patient's necessity of a post-treatment management and patients' performance rate of post-treatment management (P < 0.01). CONCLUSIONS: These results show that sufficient explanation increased patients' satisfaction after nerve block and medication. Sufficient explanation also increased the practice of patients' post-treatment management.


Asunto(s)
Humanos , Anónimos y Seudónimos , Hospitales Universitarios , Corea (Geográfico) , Bloqueo Nervioso , Clínicas de Dolor , Satisfacción del Paciente
5.
Korean Journal of Anesthesiology ; : 487-488, 2017.
Artículo en Inglés | WPRIM | ID: wpr-166108

RESUMEN

No abstract available.


Asunto(s)
Ultrasonografía , Ultrasonografía Intervencional
6.
Asian Spine Journal ; : 1122-1131, 2016.
Artículo en Inglés | WPRIM | ID: wpr-43914

RESUMEN

STUDY DESIGN: Retrospective patient data collection and investigator survey. PURPOSE: To investigate patterns of opioid treatment for pain caused by spinal disorders in Korea. OVERVIEW OF LITERATURE: Opioid analgesic prescription and adequacy of consumption measures in Korea have markedly increased in the past decade, suggesting changing patterns in pain management practice; however, there is lack of integrated data specific to Korean population. METHODS: Patient data were collected from medical records at 34 university hospitals in Korea. Outpatients receiving opioids for pain caused by spinal disorders were included in the study. Treatment patterns, including opioid types, doses, treatment duration, outcomes, and adverse drug reactions (ADRs), were evaluated. Investigators were interviewed on their perceptions of opioid use for spinal disorders. RESULTS: Among 2,468 analyzed cases, spinal stenosis (42.8%) was the most common presentation, followed by disc herniation (24.2%) and vertebral fracture (17.5%). In addition, a greater proportion of patients experienced severe pain (73.9%) rather than moderate (19.9%) or mild (0.7%) pain. Oxycodone (51.9%) and fentanyl (50.8%) were the most frequently prescribed opioids; most patients were prescribed relatively low doses. The median duration of opioid treatment was 84 days. Pain relief was superior in patients with longer treatment duration (≥2 months) or with nociceptive pain than in those with shorter treatment duration or with neuropathic or mixed-type pain. ADRs were observed in 8.6% of cases. According to the investigators' survey, "excellent analgesic effect" was a perceived advantage of opioids, while safety concerns were a disadvantage. CONCLUSIONS: Opioid usage patterns in patients with spinal disorders are in alignment with international guidelines for spinal pain management. Future prospective studies may address the suitability of opioids for spinal pain treatment by using appropriate objective measurement tools.


Asunto(s)
Humanos , Analgésicos Opioides , Dolor Crónico , Recolección de Datos , Efectos Colaterales y Reacciones Adversas Relacionados con Medicamentos , Fentanilo , Hospitales Universitarios , Corea (Geográfico) , Registros Médicos , Dolor Nociceptivo , Pacientes Ambulatorios , Oxicodona , Manejo del Dolor , Prescripciones , Estudios Prospectivos , Investigadores , Estudios Retrospectivos , Enfermedades de la Columna Vertebral , Estenosis Espinal , Columna Vertebral
7.
Korean Journal of Anesthesiology ; : 133-137, 2016.
Artículo en Inglés | WPRIM | ID: wpr-229065

RESUMEN

BACKGROUND: A "difficult airway" can be simulated with an extrication collar, which restricts cervical motion and mouth opening. The purpose of this study is to compare the efficacy of the GlideScope and the McGrath in difficult airway simulation. METHODS: Patients were randomized using computer-generated numbers and were placed into the GlideScope group or the McGrath group. The total intubation time was defined as the time measured from when the anesthesiologist picks up the device to the time at which three successive end-tidal CO2 values are acquired after intubation. RESULTS: There was no significant difference in total intubation time between the two groups (73.0 ± 25.3 sec vs. 72.3 ± 20.9 sec, P = 0.92). The success rates of the first intubation attempt did not differ between the two groups (82.8% vs. 83.3%, P = 0.95). CONCLUSIONS: Our results suggest that there are no significant differences in the intubations with GlideScope and McGrath using vascular forceps and tube exchangers in difficult intubation scenarios.


Asunto(s)
Humanos , Manejo de la Vía Aérea , Intubación , Intubación Intratraqueal , Laringoscopios , Boca , Instrumentos Quirúrgicos
8.
Korean Journal of Anesthesiology ; : 321-322, 2015.
Artículo en Inglés | WPRIM | ID: wpr-25876

RESUMEN

No abstract available.


Asunto(s)
Manejo del Dolor , Estimulación de la Médula Espinal , Médula Espinal
9.
The Korean Journal of Pain ; : 101-102, 2014.
Artículo en Inglés | WPRIM | ID: wpr-188397

RESUMEN

No abstract available.

10.
Korean Journal of Anesthesiology ; : 398-401, 2014.
Artículo en Inglés | WPRIM | ID: wpr-11887

RESUMEN

Osteonecrosis of the humeral head is an uncommon and slow progressive condition. This condition is difficult to be recognized because its initial symptoms are nonspecific. Simple radiography is the standard tool to stage disease progression. However, plain radiographic findings of osteonecrosis are nearly normal in the initial stage. We report a case of 74 years old female patient who have suffered from painful limitation of the shoulder joint. She had no trauma history and no specific predisposing factors for osteonecrosis of the humeral head. To confirm, follow up radiography and shoulder magnetic resonance imaging were performed.


Asunto(s)
Femenino , Humanos , Causalidad , Progresión de la Enfermedad , Estudios de Seguimiento , Cabeza Humeral , Imagen por Resonancia Magnética , Osteonecrosis , Radiografía , Hombro , Articulación del Hombro
11.
The Korean Journal of Pain ; : 102-103, 2013.
Artículo en Inglés | WPRIM | ID: wpr-183948

RESUMEN

No abstract available.


Asunto(s)
Bloqueo Nervioso
12.
Korean Journal of Anesthesiology ; : 431-437, 2013.
Artículo en Inglés | WPRIM | ID: wpr-188355

RESUMEN

BACKGROUND: Retrograde interlaminar ventral epidural injection (RIVEI) may hypothetically be more effective if the catheter is placed at the ventrocaudal aspect of the exiting nerve. We tested that hypothesis by measuring ventral and dorsal epidural contrast flow during RIVEI. METHODS: To perform RIVEI, a 17 G Tuohy needle was inserted to access the epidural space. A 19 G epidural catheter was inserted and advanced through the needle, passing in a caudal direction to the lower aspect of the contralateral pedicle. Fluoroscopic images were recorded at 1.5 ml increments of contrast. Based on the images of contrast dispersal, the extent of contrast spreading was assessed in 82 patients. RESULTS: All 82 patients (100%) injected with 3.0 ml contrast medium demonstrated ventral epidural spreading. Mean spreading level from the catheter tip was 2.21 +/- 0.93 with 3.0 ml of contrast. Spreading to the superior aspect of the supra-adjacent intervertebral disc was observed in 67/82 (81.7%) of RIVEIs with 3.0 ml of contrast injected into the ventral epidural space. We found that 3.0 ml of contrast reached the inferior aspect of the infra-adjacent intervertebral disc in 95.1% (78/82) of RIVEIs performed. CONCLUSIONS: Our findings imply that a one-level RIVEI may be sufficient in situations where a two-level injection would currently be used.


Asunto(s)
Humanos , Catéteres , Medios de Contraste , Espacio Epidural , Inyecciones Epidurales , Disco Intervertebral , Agujas , Compuestos Orgánicos , Compuestos de Amonio Cuaternario
13.
Anesthesia and Pain Medicine ; : 158-165, 2013.
Artículo en Inglés | WPRIM | ID: wpr-188280

RESUMEN

BACKGROUND: The aim of the study is to evaluate the relevant spreading for contrasts in the ventral and dorsal epidural space during retrograde interlaminar ventral epidural injections (RIVEIs) with the catheter tip placed ventral or dorsal to the spinal nerve. METHODS: For RIVEIs, a 17G Tuohy needle was inserted in retrograde fashion. Catheter containing a removable stylet was inserted and advanced via the needle and passed to the lower aspect of contralateral pedicles in 75 patients. Fluoroscopic images were recorded at 1.5 ml increments of contrast. Using the fluoroscopy, the contrast spreading pattern and whether the contrast spread to the specific anatomic landmarks (superior aspect of the supra-adjacent intervertebral disc [SIVD] and inferior aspect of the infra-adjacent intervertebral disc [IIVD]) were evaluated. Whether the catheter was placed ventral or dorsal to the spinal nerve was assessed with the computed tomography axial and sagittal views. RESULTS: There were no significant differences in the mean levels of epidural contrast spreading extents between ventral and dorsal catheter placements. Ventral or dorsal catheter tip placements demonstrated ventral concurrent flows over to the SIVD and IIVD over 80% of subjects with 3.0 ml of contrast. CONCLUSIONS: During RIVEIs, the catheter tip placed ventral to the spinal nerve did not show superiority with regards to epidural spreading extent as compared with dorsal catheter placement. One-level instead of a two-level injection may be considered for the two-level central pathology.


Asunto(s)
Humanos , Puntos Anatómicos de Referencia , Catéteres , Medios de Contraste , Espacio Epidural , Fluoroscopía , Inyecciones Epidurales , Disco Intervertebral , Agujas , Nervios Espinales
14.
Korean Journal of Anesthesiology ; : 103-104, 2013.
Artículo en Inglés | WPRIM | ID: wpr-117789

RESUMEN

No abstract available.


Asunto(s)
Médula Espinal
15.
Korean Journal of Anesthesiology ; : 265-267, 2013.
Artículo en Inglés | WPRIM | ID: wpr-49131

RESUMEN

The occurrence of severe hypotension and bradycardia, following placing to the beach chair position from supine during general anesthesia for repair of tendon injury of the rotator cuff of shoulder in a healthy 50 year-old man was described. The Bezold-Jarisch reflex, which is known to inhibit cardiovascular reflex and composed of three kinds of symptoms such as vasodilation, bradycardia and hypotension, has been reported mainly in peripheral nerve block, and may occur during orthostasis, hypovolemia, hemorrhage, supine inferior vena cava compression in pregnancy, interscalene block for shoulder surgery in the sitting position and so on. The bradycardia and hypotension can be more aggravated when causative elements overlaps each other. Anticholinergics and vasopressor were injected intravenously, and position of the patient was changed to the supine position immediately resulting in a normal vital signs dramatically.


Asunto(s)
Humanos , Embarazo , Anestesia General , Artroscopía , Bradicardia , Antagonistas Colinérgicos , Mareo , Hemorragia , Hipotensión , Hipovolemia , Nervios Periféricos , Reflejo , Manguito de los Rotadores , Hombro , Posición Supina , Traumatismos de los Tendones , Vasodilatación , Vena Cava Inferior , Signos Vitales
16.
Korean Journal of Anesthesiology ; : S145-S146, 2013.
Artículo en Inglés | WPRIM | ID: wpr-223189

RESUMEN

No abstract available.


Asunto(s)
Humanos , Laparoscopía , Derrame Pleural
17.
Korean Journal of Anesthesiology ; : 193-194, 2012.
Artículo en Inglés | WPRIM | ID: wpr-187716

RESUMEN

No abstract available.


Asunto(s)
Catéteres
18.
Korean Journal of Anesthesiology ; : 238-244, 2012.
Artículo en Inglés | WPRIM | ID: wpr-187708

RESUMEN

BACKGROUND: Based on the necessity to confirm the epiradicular catheter misplacement, epiradicular threshold current for the confirmation of catheter tip localization is required. METHODS: Thirty-four adult patients with low extremity radiating pain were to receive epiradicular catheterization at the lumbosacral level. The epidural space was accessed percutaneously in cranial to caudal direction. A metal coil-reinforced epidural catheter was inserted and advanced caudolaterally toward the target neural foramen until the catheter tip was located below the bisection of pedicle. The electrical stimulation was performed after catheter placement in epidural and epiradicular space. Using the constant current nerve stimulator, the stimulating current was increased from 0 to 5 mA (pulse width of 0.3 ms; frequency of 2 Hz) until adequate motor contraction was evident. The threshold current for motor response with epidural space (EDmA) and epiradicular space (ERmA) placement were recorded upon electrical stimulation. In addition, the threshold charge for motor response with epidural (EDnC) and epiradicular (ERnC) placement were recorded. RESULTS: Of 34 catheters intentionally placed in the epiradicular space, ERmA was 0.53 +/- 0.48 mA. The ERnC was significantly lower than EDnC (P < 0.05). The EDmA and ERmA were below 1 mA in 3 patients and above 1 mA in 4 patients, respectively. CONCLUSIONS: We conclude that, threshold current for motor response seems to be lower for epiradicular compared with epidural placement, although we were not able to directly investigate the epidural threshold current. The threshold current of epiradicular space overlap that in the epidural space.


Asunto(s)
Adulto , Humanos , Cateterismo , Catéteres , Contratos , Estimulación Eléctrica , Espacio Epidural , Extremidades , Honorarios y Precios , Intención
19.
Korean Journal of Anesthesiology ; : 54-58, 2012.
Artículo en Inglés | WPRIM | ID: wpr-102049

RESUMEN

BACKGROUND: In this study, we assessed the effectiveness of ketamine as an alternative to non-steroidal anti-inflammatory drugs (NSAID), to manage acute postoperative pain after spinal fusion when given intravenously via a patient-controlled analgesia (PCA) pump in which the dose was proportional to that of fentanyl. METHODS: Forty patients undergoing 1-2 level spinal fusion were enrolled in this study. Patients were intraoperatively randomized into two groups to receive intravenous PCA consisting either of fentanyl 0.4 microg/ml/kg (control group) or fentanyl 0.4 microg/ml/kg with ketamine 30 microg/ml/kg (ketamine group) after intravenous injection of a loading dose. The loading dose in the control group was fentanyl 1 microg/kg with normal saline equal to ketamine volume and in the ketamine group it was fentanyl 1 microg/kg with ketamine 0.2 mg/kg. The verbal numerical rating scale (NRS), fentanyl and ketamine infusion rate, and side effects were evaluated at 1, 24, and 48 hours after surgery. RESULTS: There were no significant differences in patient demographics, duration of surgery and anesthesia or intra-operative opioids administration. We did not find any significant differences in the mean infusion rate of intraoperative remifentanil or postoperative fentanyl or in the side effects between the groups, but we did find a significant difference in the NRS between the groups. CONCLUSIONS: Based on our results, we conclude that a small dose of ketamine (0.5-2.5 microg/kg/min) proportional to fentanyl is not only safe, but also lowers postoperative pain intensity in patients undergoing spinal fusion, although the opioid-sparing effects of ketamine were not demonstrated.


Asunto(s)
Humanos , Analgesia Controlada por el Paciente , Analgésicos Opioides , Anestesia , Demografía , Fentanilo , Bombas de Infusión , Inyecciones Intravenosas , Ketamina , Dolor Postoperatorio , Anafilaxis Cutánea Pasiva , Piperidinas , Estudios Prospectivos , Fusión Vertebral
20.
Anesthesia and Pain Medicine ; : 221-225, 2012.
Artículo en Inglés | WPRIM | ID: wpr-74821

RESUMEN

BACKGROUND: Electrical stimulation can be used to verify the location of epidural catheters. Although epiradicular localization of a catheter is important for patients with radiating pain in the lower extremities due to spinal stenosis or disc herniation, no prospective study results pertaining to the stimulation threshold within the epiradicular space have been reported. Therefore, we set out to investigate the threshold current for motor response in the epiradicular space by the use of a catheter containing a removable stylet. In addition, this study examines the reliability of such epiradicular stimulation. METHODS: In 105 patients undergoing a retrograde interlaminar ventral epidural injection, a lumbar epiradicular catheter was inserted. Loss of resistance was used to identify the epidural space. Afterward, the TheraCath was advanced into the epiradicular space and connected to a nerve stimulator. A nerve stimulator delivered progressively, increasing electrical current until an appropriate muscle contraction was observed. Contrast media was then injected and epiradicular dispersal was assessed. RESULTS: Epiradicular stimulation yielded a mean threshold of 0.56 +/- 0.50 mA (range: 0.06 to 2.84). When compared with epiradicular dispersal as a gold standard, the sensitivity, specificity, positive predictive value, and negative predictive value of epiradicular stimulation with the TheraCath were 90%, 56%, 96% and 33%, respectively. CONCLUSIONS: The threshold current of an insulated needle required to elicit a motor response in the epiradicular space was evaluated. We conclude that the epiradicular stimulation test is useful for confirming catheter placement. Nonetheless, further studies are required before implementing its routine use in clinical settings.


Asunto(s)
Humanos , Catéteres , Medios de Contraste , Estimulación Eléctrica , Espacio Epidural , Inyecciones Epidurales , Extremidad Inferior , Contracción Muscular , Agujas , Estenosis Espinal
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA