Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Añadir filtros








Intervalo de año
1.
Korean Journal of Blood Transfusion ; : 43-48, 2008.
Artículo en Coreano | WPRIM | ID: wpr-57128

RESUMEN

BACKGROUND: The AutoVue Innova (Ortho Clinical Diagnostic, Raritan, NJ, USA) is an automatic instrument for blood bank tests, and it has recently been introduced in Korea for the first time at our hospital. This instrument employs column agglutination technology and it performs blood bank tests automatically. We evaluated this instrument and we report on the results. METHODS: We performed ABO/RhD typing and antibody screening for 250 randomly selected samples, and crossmatching for 261 samples with using the AutoVue Innova in parallel with the conventional manual methods. For a sensitivity test, we added 3 samples of A(2)B(3) and 2 samples of weak-D and serially diluted reagent antisera to the test pool and we measured turnaround time (TAT) for the antibody screening test. RESULTS: The concordance rates between AutoVue Innova and the manual methods for ABO/RhD blood typing, antibody screening and crossmatching tests were 99.6%, 100% and 98.9%, respectively. The overall retest rate was 0.5% and the main cause of the discrepancy was revealed to be hemolysis or an inadequate amount of the samples. The overall sensitivity of AutoVue Innova seems to be same as or better than the manual methods. The TAT for the antibody screening test was significantly shorter for the AutoVue Innova (64+/-43 min, n=512) than for the tube method (89+/-57 min, n=99) (P<0.001). CONCLUSION: The test results of AutoVue Innova were accurate and sensitive for the ABO/RhD typing, crossmatching and antibody screening tests. The TAT for the antibody screening test was remarkably shortened up to five times more samples could be tested without an increase of manpower.


Asunto(s)
Aglutinación , Bancos de Sangre , Tipificación y Pruebas Cruzadas Sanguíneas , Hemólisis , Sueros Inmunes , Corea (Geográfico) , Tamizaje Masivo
2.
Korean Journal of Blood Transfusion ; : 63-67, 1995.
Artículo en Coreano | WPRIM | ID: wpr-213678

RESUMEN

An ABO discrepancy was encountered in a 29-year-old woman with a pregnancy of 36 weeks. The patient's red cell was typed as group O and her serum had only anti-A antibody. Absence of B antigen on patient's RBC was confirmed by adsorption-elution test, B substance was not demonstrated in the saliva and serum. B-transferase activity was not detected in the serum. Patient's serum Ig level was within normal range. The patient's father and son had normal O phenotype and no additional abnormalities were detected among the family members studied.


Asunto(s)
Adulto , Femenino , Humanos , Embarazo , Padre , Fenotipo , Valores de Referencia , Saliva
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA