Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Añadir filtros








Intervalo de año
1.
China Journal of Orthopaedics and Traumatology ; (12): 73-76, 2016.
Artículo en Chino | WPRIM | ID: wpr-304345

RESUMEN

<p><b>OBJECTIVE</b>To observe the incidence, causes and deviation angle of axial offset in patients with fracture ununited treated by Ilizarov bone transport technology.</p><p><b>METHODS</b>From January 2007 to December 2012, 10 patients with fracture ununited were treated by Ilizarov bone transport including 8 males and 2 females with an average age of (30.3 ± 10.6) years old ranging from 18 to 49 years old. The segment of bone defect involved upper tibial in 2 cases, medial tibia in 2 cases, lower tibial in 5 cases, upper femoral in 1 case. For Paley type of bone defect, 6 cases were type B1, 4 cases were B3. The incidence and deviation angle of axial offset after Ilizarov bone transport technology were observed and evaluated on bone result by Paley assessment.</p><p><b>RESULTS</b>All patients were followed up from 19 to 32 months with an average of (22.0 ± 5.6) months. Three cases were natural healed at fracture ends, the other 7 cases were healed after bone graft. The time of external fixator was 16 to 28 months. At the last follow-up, there were 3 cases occurred coronal angulation of angle 5° to 11° with an average of (8.7 ± 3.2). Sagittal angulation was in 4 cases, angle 6° to 9° with an average of (8.5 ± 2.1)°. There were 4 cases occurred axial offset. In the last follow-up, according to Paley evaluation criteria, osseous results were excellent in 7 cases, good in 3 cases; functional results were excellent in 6 cases, good in 4 cases.</p><p><b>CONCLUSION</b>Axial deviation after the Ilizarov bone transport treatment is relatively common, which will result in delayed healing of bone and poor limb alignment. In order to improve the bone healing, corresponding measurements should be taken to avoid or reduce the incidence of axial deviation during and after the operation.</p>


Asunto(s)
Adolescente , Adulto , Femenino , Humanos , Masculino , Persona de Mediana Edad , Curación de Fractura , Fracturas no Consolidadas , Cirugía General , Técnica de Ilizarov
2.
China Journal of Orthopaedics and Traumatology ; (12): 757-758, 2008.
Artículo en Chino | WPRIM | ID: wpr-323211

RESUMEN

<p><b>OBJECTIVE</b>To investigate the operative method and effect of the reversed sural neurocutaneous flap in repairing soft tissue defects of the anterior foot and the ankle.</p><p><b>METHODS</b>From March 1999 to November 2004, 19 cases (17 male, 2 female) of soft tissue defects of the anterior foot and the ankle were repaired with the reversed sural neurocutaneous flaps. The flap sizes range from 18 cm x 9 cm to 30 cm x 18 cm.</p><p><b>RESULTS</b>All flaps survived well, while 1 flap had distal partial necrosis and healed after dressing change. The follow-up from 6 months to 2 years showed that all flaps were satisfactory.</p><p><b>CONCLUSION</b>Sural neurocutaneous flap is easy to get and to survive. It is an effective method to repair the soft tissue defects of the anterior foot and the ankle.</p>


Asunto(s)
Adolescente , Adulto , Femenino , Humanos , Masculino , Persona de Mediana Edad , Tobillo , Cirugía General , Pie , Cirugía General , Procedimientos de Cirugía Plástica , Traumatismos de los Tejidos Blandos , Cirugía General , Colgajos Quirúrgicos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA