RESUMEN
OBJECTIVE@#To investigate the clinical effect of unilateral percutaneous vertebroplasty (PVP) combined with 3D printing technology for the treatment of thoracolumbar osteoporotic compression fracture.@*METHODS@#A total of 77 patients with thoracolumbar osteoporotic compression fractures from October 2020 to April 2022 were included in the study, all of which were vertebral body compression fractures caused by trauma. According to different treatment methods, they were divided into experimental group and control group. Thirty-two patients used 3D printing technology to improve unilateral transpedicle puncture vertebroplasty in the experimental group, there were 5 males and 27 females, aged from 63 to 91 years old with an average of (77.59±8.75) years old. Forty-five patients were treated with traditional bilateral pedicle puncture vertebroplasty, including 7 males and 38 females, aged from 60 to 88 years old with an average of(74.89±7.37) years old. Operation time, intraoperative C-arm X-ray times, anesthetic dosage, bone cement injection amount, bone cement diffusion good and good rate, complications, vertebral height, kyphotic angle (Cobb angle), visual analogue scale(VAS), Oswestry disability index (ODI) and other indicators were recorded before and after surgery, and statistically analyzed.@*RESULTS@#All patients were followed up for 6 to 23 months, with preoperative imaging studies, confirmed for thoracolumbar osteoporosis compression fractures, two groups of patients with postoperative complications, no special two groups of patients' age, gender, body mass index (BMI), time were injured, the injured vertebral distribution had no statistical difference(P>0.05), comparable data. Two groups of patients with bone cement injection, bone cement dispersion rate, preoperative and postoperative vertebral body height, protruding after spine angle(Cobb angle), VAS, ODI had no statistical difference(P>0.05). The operative time, intraoperative fluoroscopy times and anesthetic dosage were statistically different between the two groups(P<0.05). Compared with the traditional bilateral puncture group, the modified unilateral puncture group combined with 3D printing technology had shorter operation time, fewer intraoperative fluoroscopy times and less anesthetic dosage. The height of anterior vertebral edge, kyphosis angle (Cobb angle), VAS score and ODI of the affected vertebrae were statistically different between two groups at each time point after surgery(P<0.05).@*CONCLUSION@#In the treatment of thoracolumbar osteoporotic compression fractures, 3D printing technology is used to improve unilateral puncture PVP, which is convenient and simple, less trauma, short operation time, fewer fluoroscopy times, satisfactory distribution of bone cement, vertebral height recovery and kyphotic Angle correction, and good functional improvement.
Asunto(s)
Masculino , Femenino , Humanos , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Fracturas por Compresión/cirugía , Fracturas de la Columna Vertebral/cirugía , Cementos para Huesos , Resultado del Tratamiento , Vertebroplastia/métodos , Cifosis/cirugía , Punciones , Impresión Tridimensional , Tecnología , Fracturas Osteoporóticas/cirugía , Anestésicos , Estudios Retrospectivos , Cifoplastia/métodosRESUMEN
OBJECTIVE@#To evaluate accuracy and safety of individualized 3D printing guided template for thoracolumbar pedicle screw placement in patients with ankylosing spondylitis.@*METHODS@#From January 2016 to September 2019, thoracolumbar spine three-dimensional CT data of 8 patients with ankylosing spondylitis were included, Mimics 17.0 and ideaMaker computer software were applied to design thoracolumbar pedicle screw guided template of patients with AS, physical model of all patients (T-L)were printed by 3D printer, 2 parts in each patient, and divided into guide-plate-assisted screw group (experimental group) and free-hand nail group (control group). Thoracolumbar pedicle screws of both groups were placed by the same spinal surgeon. The accuracy of pedicle screw placement between two groups were evaluated according to results of postoperative CT, the accuracy of the fixation of thoracolumbar pedicle screw was divided into 4 grades, grade 0 and 1 screws were acceptable nails, grade 2 and 3 screws were unacceptable nails. The diameter and length of pedicle screws, the distance between entry point and posterior median line designed by preoperative 3D printing were compared with actual use in operation.@*RESULTS@#Twenty three blocks of thoracolumbar 3D printing screw of ankylosing spondylitis guided templates were designed and printed in guide-plate-assisted screw group, 46 screws were inserted and 44 screws were accepted. The time of implanting a screw into thoracolumbar pedicle was (4.20±1.15) min, the frequency of X-ray was (5.00±1.25) times and the average adjustment times of screw and Kirschner needle during screw placement was (1.76±1.32) times. In the control group, 46 nails were placed by traditional surgical method and 30 screws were accepted. The time of implanting a screw into thoracolumbar pedicle was (14.67±2.23) min, the frequency of X-ray fluoroscopy was (14.46±2.21) times and the average times of Kirschner needle adjustment was (4.76±3.39) times. The success rates between experimental group and control group were 95.65%(44 / 46) and 56.22%(30 / 46) respectively, and had statistical difference (χ=13.538, 0.05). The operation time of inserting a single screw, the times of X-ray fluoroscopy, and the average times of adjustment screw and Kirschner needle in experimental group were significant less than those in control group(<0.01).@*CONCLUSION@#The personalized guide template assisted the thoracolumbar fixation designed by 3D printing could significantly improve safety, accuracy and efficiency of surgery, especially suitable for thoracolumbar vertebral bodies requiring posterior pedicle screw fixation for fracture or dislocation with AS.