Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Añadir filtros








Intervalo de año
1.
Tissue Engineering and Regenerative Medicine ; (6): 549-571, 2019.
Artículo en Inglés | WPRIM | ID: wpr-786678

RESUMEN

BACKGROUND: Tendon and ligament injuries accounted for 30% of all musculoskeletal consultations with 4 million new incidences worldwide each year and thus imposed a significant burden to the society and the economy. Damaged tendon and ligament can severely affect the normal body movement and might lead to many complications if not treated promptly and adequately. Current conventional treatment through surgical repair and tissue graft are ineffective with a high rate of recurrence.METHODS: In this review, we first discussed the anatomy, physiology and pathophysiology of tendon and ligament injuries and its current treatment. Secondly, we explored the current role of tendon and ligament tissue engineering, describing its recent advances. After that, we also described stem cell and cell secreted product approaches in tendon and ligament injuries. Lastly, we examined the role of the bioreactor and mechanical loading in in vitro maturation of engineered tendon and ligament.RESULTS: Tissue engineering offers various alternative ways of treatment from biological tissue constructs to stem cell therapy and cell secreted products. Bioreactor with mechanical stimulation is instrumental in preparing mature engineered tendon and ligament substitutes in vitro.CONCLUSIONS: Tissue engineering showed great promise in replacing the damaged tendon and ligament. However, more study is needed to develop ideal engineered tendon and ligament.


Asunto(s)
Reactores Biológicos , Exosomas , Técnicas In Vitro , Incidencia , Ligamentos , Fisiología , Recurrencia , Derivación y Consulta , Células Madre , Tendones , Ingeniería de Tejidos , Trasplantes
2.
Tissue Engineering and Regenerative Medicine ; (6): 75-87, 2018.
Artículo en Inglés | WPRIM | ID: wpr-742373

RESUMEN

Umbilical cord (UC) is a discarded product from the operating theatre and a ready source of mesenchymal stromal cells (MSCs). MSCs from UC express both embryonic and adult mesenchymal stem cell markers and are known to be hypoimmunogenic and non-tumorigenic and thus suitable for allogeneic cell transplantation. Our study aimed to determine the degree of immunotolerance and bone-forming capacity of osteodifferentiated human Wharton's jelly-derived mesenchymal stromal cells (hWJ-MSCs) from different segments of UC in an allogenic setting. UCs were obtained from healthy donors delivering a full-term infant by elective Caesarean section. hWJ-MSCs were isolated from 3 cm length segment from the maternal and foetal ends of UCs. Three-dimensional fibrin constructs were formed and implanted intramuscularly into immunocompetent mice. The mice were implanted with 1) fibrin construct with maternal hWJ-MSCs, 2) fibrin construct with foetal hWJ-MSCs, or 3) fibrin without cells; the control group received sham surgery. After 1 month, the lymphoid organs were analysed to determine the degree of immune rejection and bone constructs were analysed to determine the amount of bone formed. A pronounced immune reaction was noted in the fibrin group. The maternal segment constructs demonstrated greater osteogenesis than the foetal segment constructs. Both maternal and foetal segment constructs caused minimal immune reaction and thus appear to be safe for allogeneic bone transplant. The suppression of inflammation may be a result of increased anti-inflammatory cytokine production mediated by the hWJ-MSC. In summary, this study demonstrates the feasibility of using bone constructs derived from hWJ-MSCs in an allogenic setting.


Asunto(s)
Adulto , Animales , Femenino , Humanos , Lactante , Ratones , Embarazo , Regeneración Ósea , Trasplante de Células , Cesárea , Fibrina , Inflamación , Células Madre Mesenquimatosas , Osteogénesis , Donantes de Tejidos , Ingeniería de Tejidos , Trasplantes , Cordón Umbilical , Gelatina de Wharton
3.
Tissue Engineering and Regenerative Medicine ; (6): 699-718, 2017.
Artículo en Inglés | WPRIM | ID: wpr-657083

RESUMEN

Electrospinning is a simple and versatile technique to fabricate continuous fibers with diameter ranging from micrometers to a few nanometers. To date, the number of polymers that have been electrospun has exceeded 200. In recent years, electrospinning has become one of the most popular scaffold fabrication techniques to prepare nanofiber mesh for tissue engineering applications. Collagen, the most abundant extracellular matrix protein in the human body, has been electrospun to fabricate biomimetic scaffolds that imitate the architecture of native human tissues. As collagen nanofibers are mechanically weak in nature, it is commonly cross-linked or blended with synthetic polymers to improve the mechanical strength without compromising the biological activity. Electrospun collagen nanofiber mesh has high surface area to volume ratio, tunable diameter and porosity, and excellent biological activity to regulate cell function and tissue formation. Due to these advantages, collagen nanofibers have been tested for the regeneration of a myriad of tissues and organs. In this review, we gave an overview of electrospinning, encompassing the history, the instrument settings, the spinning process and the parameters that affect fiber formation, with emphasis given to collagen nanofibers' fabrication and application, especially the use of collagen nanofibers in skin tissue engineering.


Asunto(s)
Humanos , Biomimética , Colágeno , Matriz Extracelular , Cuerpo Humano , Nanofibras , Polímeros , Porosidad , Regeneración , Piel , Ingeniería de Tejidos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA