Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Añadir filtros








Intervalo de año
1.
International Journal of Surgery ; (12): 717-720, 2022.
Artículo en Chino | WPRIM | ID: wpr-954282

RESUMEN

The internal iliac artery originating from the common iliac artery is an important branch, and communicating with the branches of the abdominal aorta, such as lumbar artery and sacral median artery, forming rich collateral circulation and nourishing the blood supply of gluteal muscle and pelvic floor viscera. Surgical intervention is recommended when the maximum diameter of internal iliac artery aneurysms>2 cm. A variety of treatment modalities are available, particularly, endovascular technique has been successfully applied in the clinical treatment of internal iliac artery aneurysms, which can significantly improve the cure and reduce complications and deaths. This article reviews the previous literature and summarizes the progress of internal iliac artery aneurysms treatment.

2.
Chinese Journal of Medical Imaging ; (12): 105-108, 2017.
Artículo en Chino | WPRIM | ID: wpr-505831

RESUMEN

Purpose To explore the feasibility of low radiation dose combined with lowdose contrast agent in thyroid CT enhanced scan and investigate the benefit of reducing radiation hazard and contrast agent damage to thyroid.Materials and Methods 120 patients assigned for thyroid enhanced CT scan were prospectively and randomly divided into four groups (each group was 30 patients).Group A:radiation dose 120 kV,180 mA,contrast agent dose 1.2 ml/kg;group B:radiation dose 120 kV,180 mA,contrast agent dose 1.0 ml/kg;group C:radiation dose 100 kV,100 mA,contrast agent dose 1.2 ml/kg;group D:radiation dose 100 kV,100 mA,contrast agent dose 1.0 ml/kg.CT values,background sign,background noise of thyroid were measured;signal to noise ratio (SNR) and contrast to noise ratio (CNR) were calculated;CT dose index of volume (CTDIvol),dose length product (DLP),and the effective dose (ED) were recorded and calculated.The image quality was evaluated and the data was statistically analyzed by two radiologists.Results CT values,background sign and background noise of thyroid,as well as CTDIvol,DLP,ED among four groups were statistical significant (P<0.05);there was no significant difference in SNR,CNR and image quality scores among four groups (P>0.05).Conclusion It is beneficial of reducing radiation hazard and side-effect of contrast agent from low radiation dose combined with low-dose contrast agent under the condition of ensuring diagnostic image quality.

3.
Journal of Practical Radiology ; (12): 1116-1118, 2016.
Artículo en Chino | WPRIM | ID: wpr-495891

RESUMEN

Objective To evaluate the value of multi-slice spiral CT Low-dose scanning technology in thyroid enhanced scan. Methods Eighty patients were randomly divided into four groups including Group A:120 kV,180 mA;Group B:120 kV,100 mA;Group C:100 kV,180 mA and Group D:100 kV,100 mA.The subjective image quality was evaluated and scored.Thyroid CT val-ue,image background noise (N),image signal to noise ratio (SNR),CT dose index (CTDIvol),dose length product (DLP),and the effective radiation dose (ED)were measured and compared.Results The subjective image scores and SNR of these four groups were 3.90±0.31 and 26.34±3.13,3.75±0.44 and 25.08 ±1.87,3.70 ±0.47 and 25.86 ±2.38,3.60 ±0.60 and 24.87 ±2.20 respectively.There were no significantly statistical differences among the subjective image scores and SNR (P > 0.05 )of the 4 Groups.Thyroid CT values,N,CTDIvol,DLP and ED were (1 68.55 ± 13.39)HU,(6.48 ±0.84)HU,(10.95 ±0.00)mGy, (145.67±8.79)mGy·cm,(0.73±0.04)mSv in Group A,(170.70±11.34)HU,(6.83±0.45)HU,(6.08±0.00)mGy,(84.58± 4 .9 4)mGy· cm,(0 .4 2 ±0 .0 3 )mSv in Group B,(1 8 5 .2 0 ±2 2 .3 5 )HU,(7 .1 9 ±0 .8 6 )HU,(6 .5 9 ±0 .0 0 )mGy,(8 9 .8 6 ± 3 .2 6 )mGy· cm,(0 .4 5 ±0 .0 3 )mSv in Group C,(1 9 0 .5 5 ±2 1 .3 8 )HU,(7 .6 6 ± 1 .0 1 )HU,(3 .6 6 ±0 .0 0 )mGy,(5 0 .2 0 ± 1 .8 9 )mGy·cm,(0.25±0.01)mSv in Group D respectively.There were significantly statistical differences among different thyroid CT values,N,CTDIvol,DLP and ED (P <0.05).Conclusion Multi-slice spiral CT low-dose scanning technology in thyroid en-hanced scan can guarantee the image quality and effectively reduce thyroid radiation dose.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA