Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Añadir filtros








Intervalo de año
1.
Chinese Journal of Blood Transfusion ; (12): 813-815, 2017.
Artículo en Chino | WPRIM | ID: wpr-607319

RESUMEN

Objective To compare the differences of two kinds of EIA reagents for HIV-1/2 (Ab/Ag) screening results of voluntary blood donors,in addition to find out the feasibility of reducing 1 times of EIA detection.Methods To collect data of HIV 1/2 screening positive results and confirmatory test for voluntary blood donors from 2009 to 2014 in Jiaxing area,and to compare the relationship of screeing test results with that of the confirmatory test,and then to analyze the relevance between S/CO values of screening test and confirmatory test.Results Screening positive rates of domestic and imported reagents,which were 9.58/10 000 and 12.43/10 000,respectively;and the confirmatory coincidence rates were 11.84% and 9.12%,respectively.There was no significant difference (x2 =1.11,P>0.05).The double-reagent joint detection positive rate was 1.37/10 000,and its positive predictive value was 82.86%.Single-reagent test result compared with that of double-reagent test,which had significant differences (x2domestic =94.04,P<0.05 and x2ximported =124.86,P<0.05).When the S/CO value was more than 6,domestic and imported reagents positive predictive values were 93.55% (29/31) and 87.50% (28/32),respectively.Conclusion There is no difference between domestic and imported reagents EIA-HIV1/2.

2.
Chinese Journal of Medical Instrumentation ; (6): 85-89, 2012.
Artículo en Chino | WPRIM | ID: wpr-325925

RESUMEN

Microvessel networks were imaged by means of synchrotron radiation CT, A sliced loading and double threshold method was utilized for extracting vessels from large quantities of data (2 GB-5 GB). Preliminary analysis on the development of tumor microvessel networks was performed by statistically analyzing volume rendering and two qualitative factors, micro vessel density (MVD) and fractal dimension(FD).


Asunto(s)
Animales , Femenino , Ratones , Ratones Endogámicos BALB C , Ratones Desnudos , Microvasos , Diagnóstico por Imagen , Neoplasias , Diagnóstico por Imagen , Neovascularización Patológica , Diagnóstico por Imagen , Patología , Microtomografía por Rayos X , Métodos
3.
Chinese Journal of Medical Instrumentation ; (6): 172-176, 2012.
Artículo en Chino | WPRIM | ID: wpr-325902

RESUMEN

A novel system is proposed to control the liquid nitrogen cooling and radio frequency heating of tissue to achieve effective thermal ablation in the treatment using fuzzy logic controller and fuzzy logic PID type controller separately. Results of ex-vivo pig liver experiments demonstrate that this system is useful and could p control the desired treatment procedure.


Asunto(s)
Animales , Algoritmos , Simulación por Computador , Crioterapia , Métodos , Electrocoagulación , Métodos , Diseño de Equipo , Lógica Difusa , Hígado , Porcinos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA