Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Añadir filtros








Intervalo de año
1.
The Korean Journal of Hepatology ; : 521-529, 2007.
Artículo en Coreano | WPRIM | ID: wpr-36323

RESUMEN

BACKGROUND AND AIMS: FibroScan(R) is a new medical device that noninvasively measures liver stiffness. The aim of this study was to assess the accuracy of the liver stiffness measurement by FibroScan(R) for making the diagnosis of liver fibrosis in patients with chronic viral hepatitis. METHODS: We studied 103 patients with chronic viral hepatitis B or C and they underwent FibroScan(R) and liver biopsy between October 2005 and August 2006. Liver fibrosis was staged on a 0-4 scale according to the Korean Society of Pathologists Scoring System. The diagnostic accuracy was assessed by analysis of the receiver operator characteristics (ROC). RESULTS: The liver stiffness was 3.5-57.1 kPa (mean: 11.8, SD: 8.9). The mean value of liver stiffness in each fibrosis stage group (F1, F2, F3 and F4) was 5.8+/-1.8 kPa, 11.3+/-6.8 kPa, 11.8+/-6.0 kPa and 23.4+/-16.5 kPa, respectively. Liver stiffness measured by FibroScan(R) showed reliable correlation with the liver fibrosis stage as confirmed by liver biopsy (r=0.56, p or = F2, > or = F3 and F4 was 0.93 (0.86-0.99), 0.72 (0.62-0.82) and 0.80 (0.67-0.92), respectively. The sensitivity and specificity of 7.5 kPa, which was the cutoff value for > or = F2, was 84% and 90%, respectively. CONCLUSIONS: FibroScan(R) is a reliable method for the diagnosis of significant fibrosis (> or =F2) and cirrhosis in patients with chronic liver disease. The liver stiffness measurement by FibroScan(R) showed good diagnostic performance for significant fibrosis.


Asunto(s)
Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Progresión de la Enfermedad , Hepatitis B Crónica/complicaciones , Hepatitis C Crónica/complicaciones , Hígado/diagnóstico por imagen , Cirrosis Hepática/etiología , Valor Predictivo de las Pruebas , Curva ROC , Sensibilidad y Especificidad
2.
Tuberculosis and Respiratory Diseases ; : 404-409, 2005.
Artículo en Coreano | WPRIM | ID: wpr-209460

RESUMEN

An 86 year old woman was admitted complaining of dyspnea and right pleuritic pain with a 5 week durations. A physical examination, chest X-ray, and diagnostic thoracentesis upon admission revealed findings consistent with severe pneumonia and empyema on the right lung. Despite the insertion of a chest tube and negative suction via Emersion pump, the continuous air leakage was sustained, and a bronchopleural fistula (BPF) was found on the chest-CT. A flexible bronchoscopic occlusion with an Endobronchial Watanabe Spigot (EWS) was performed after 56 days of admission. An 5 mm diameter EWS was successfully inserted into the anterior segmental bronchus of the right upper lobe by flexible bronchoscope. There was no aAir leakage detected after this procedure. The patient was discharged 30 days after the EWS occlusion.


Asunto(s)
Anciano de 80 o más Años , Femenino , Humanos , Bronquios , Broncoscopios , Tubos Torácicos , Disnea , Empiema , Fístula , Pulmón , Examen Físico , Neumonía , Succión , Tórax
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA