Chinese Journal of Medical Instrumentation ; (6): 26-31, 2021.
Artículo en Chino | WPRIM | ID: wpr-880417

RESUMEN

In order to obtain the three-dimensional pulse information and blood pressure waveform needed in the study, a radial artery simulation platform with programmable controlled injection pump as the core was constructed by using the circulation theory of human cardiovascular system and pulse wave formation mechanism. Gaussian function model was selected to synthesize multi-type pulse wave to program and drive the platform. The three-dimensional pulse information and blood pressure waveform of the simulated radial artery were collected by binocular visual pulse detection system and pressure transmitter respectively, and the platform stability and repeatability were tested by Pearson correlation. The experimental results show that the radial artery simulation platform is stable, reliable and repeatable, and can generate multiple types of three-dimensional pulse information and blood pressure waveform at the simulated radial artery. The platform is simple in structure, low in cost, and produces many types of pulsating flow. It provides an experimental research platform for revealing the relationship between the three-dimensional pulse information of radial artery and the change of pressure inside the vessel, as well as the prediction of blood pressure waveform from the three-dimensional pulse information.


Asunto(s)
Humanos , Presión Sanguínea , Simulación por Computador , Frecuencia Cardíaca , Arteria Radial , Signos Vitales
2.
Chinese Journal of Medical Imaging Technology ; (12): 929-933, 2018.
Artículo en Chino | WPRIM | ID: wpr-706359

RESUMEN

Objective To explore an auxiliary method to improve DWI image quality of testis.Methods Thirty healthy male volunteers were selected,and EPI-DWI and FSE-T2WI scanning with the same parameters were successively performed according to three different schemes.Scheme A:Padding ultrasonic coupling agent-soft rubber bag at the scanning position.Scheme B:Padding physiological saline-soft rubber bag at the scanning position.Scheme C:No preexamination treatment at the scanning position.FSE-T2WI (the same scheme and the same slice) was used as the reference of anatomic form,and the images were conducted by two attending doctors.The image geometric distortion,signal uniformity and anatomical clarity were scored by 5 points method.SNR and CNR of were calculated by one of the two doctors.The scoring consistency between the two doctors was evaluated.The scoring of image geometric distortion,signal uniformity,anatomic clarity,SNR and CNR of the three schemes were statistically analyzed.Results The scoring consistency of image geometrical distortion,signal uniformity and anatomical clarity of the three schemes were relatively good or better between the two doctors (Kappa=0.805,0.737 and 0.713).There were significant differences of image geometrical distortion,signal uniformity and anatomical clarity scoring obtained from three schemes (comparisons between groups and overall comparison,all P< 0.05),superiority:Scheme A> Scheme B> Scheme C.Conclusion Ultrasonic coupling agent-soft rubber bag padding method can significantly improve DWI imaging quality of testis.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA