Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Añadir filtros








Intervalo de año
1.
Chinese Journal of Nuclear Medicine and Molecular Imaging ; (6): 550-554, 2017.
Artículo en Chino | WPRIM | ID: wpr-607124

RESUMEN

Objective To evaluate the role of 131I SPECT/CT in post-surgical re-staging and recurrence risk stratification in patients with DTC and its impact on subsequent treatment strategy.Methods 131I-WBS and 131I SPECT/CT were performed at the same time 5 to 7 d after 131I treatment in 118 patients (33 males,85 females,average age 45 years) with DTC.Difference in the localization and qualitative diagnosis of 131I uptake lesions between 131I-WBS and 131I SPECT/CT were compared.Value of 131I SPECT/CT in the diagnosis of TNM staging,risk stratification and impact on the treatment strategy was evaluated.Paired χ2 test was used for data analysis.Results A total of 509 foci with 131I uptake were detected.131I-WBS found 449 foci with 131I uptake,354 of which (78.84%) were correctly diagnosed.131I SPECT/CT found 509 foci with 131I uptake,and 504(99.02%) were correctly diagnosed.The difference was statistically significant (χ2=21.51,P<0.01).131I-WBS changed the clinical staging in 13 cases with diagnostic accuracy of 5/13.131I SPECT/CT changed the clinical staging in 19 cases and with diagnostic accuracy of 19/19 (χ2=74.41,P<0.01).131I-WBS changed the risk stratification of 13 patients after operation and the accuracy was 5/13,the corresponding data were 22 and 100%(22/22) for 131I SPECT/CT (χ2=74.41,P<0.01).The treatment strategy was changed in 50 patients with 131I SPECT/CT.Conclusions Compared with 131I-WBS,131I SPECT/CT could provide more accurate positioning and qualitative information for 131I treatment and is more accurate in re-staging and risk stratification.

2.
Chinese Journal of Medical Imaging Technology ; (12): 1892-1895, 2009.
Artículo en Chino | WPRIM | ID: wpr-472421

RESUMEN

Objective To compare the value of (~99m) Tc-octreotide scintigraphy and planar X-ray mammography in the diagnosis of breast cancer. Methods A total of 32 patients with suspected breast cancer were enrolled into this study. All patients underwent (~99m) Tc-octreotide scintigraphy and planar X-ray mammography. The diagnostic efficiency of (~99m) Tc-octreotide scintigraphy and planar X-ray mammography were compared based on the post-surgery pathology. Results The sensitivity of (~99m) Tc-octreotide scintigraphy and planar X-ray mammography in the diagnosis of breast cancer was 91.67% and 66.67%, the specificity was 100% and 37.50%, the accuracy was 93.75% and 59.38%, respectively. Combining (~99m) Tc-octreotide scintigraphy with planar X-ray mammography, the sensitivity, specificity, accuracy, positive predicting values and negative predicting values for breast cancer was 95.83%, 100%, 96.88%, 82.14% and 47.06%, respectively. Conclusion The diagnostic efficiency of (~99m) Tc-octreotide scintigraphy for breast cancer is superior to planar X-ray mammography. (~99m) Tc-octreotide scintigraphy combined with planar X-ray mammography, the diagnostic efficiency for breast cancer will be further improved.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA