Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
J. biomed. eng ; Sheng wu yi xue gong cheng xue za zhi;(6): 133-140, 2023.
Artículo en Chino | WPRIM | ID: wpr-970683

RESUMEN

To investigate the γ pass rate limit of plan verification equipment for volumetric modulated arc therapy (VMAT) plan verification and its sensitivity on the opening and closing errors of multi-leaf collimator (MLC), 50 cases of nasopharyngeal carcinoma VMAT plan with clockwise and counterclockwise full arcs were randomly selected. Eight kinds of MLC opening and closing errors were introduced in 10 cases of them, and 80 plans with errors were generated. Firstly, the plan verification was conducted in the form of field-by-field measurement and true composite measurement. The γ analysis with the criteria of 3% dose difference, distance to agreement of 2 mm, 10% dose threshold, and absolute dose global normalized conditions were performed for these fields. Then gradient analysis was used to investigate the sensitivity of field-by-field measurement and true composite measurement on MLC opening and closing errors, and the receiver operating characteristic curve (ROC) was used to investigate the optimal threshold of γ pass rate for identifying errors. Tolerance limits and action limits for γ pass rates were calculated using statistical process control (SPC) method for another 40 cases. The error identification ability using the tolerance limit calculated by SPC method and the universal tolerance limit (95%) were compared with using the optimal threshold of ROC. The results show that for the true composite measurement, the clockwise arc and the counterclockwise arc, the descent gradients of the γ passing rate with per millimeter MLC opening error are 10.61%, 7.62% and 6.66%, respectively, and the descent gradients with per millimeter MLC closing error are 9.75%, 7.36% and 6.37%, respectively. The optimal thresholds obtained by the ROC method are 99.35%, 97.95% and 98.25%, respectively, and the tolerance limits obtained by the SPC method are 98.98%, 97.74% and 98.62%, respectively. The tolerance limit calculated by SPC method is close to the optimal threshold of ROC, both of which could identify all errors of ±2 mm, while the universal tolerance limit can only partially identify them, indicating that the universal tolerance limit is not sensitive on some large errors. Therefore, considering the factors such as ease of use and accuracy, it is suggested to use the true composite measurement in clinical practice, and to formulate tolerance limits and action limits suitable for the actual process of the institution based on the SPC method. In conclusion, it is expected that the results of this study can provide some references for institutions to optimize the radiotherapy plan verification process, set appropriate pass rate limit, and promote the standardization of plan verification.


Asunto(s)
Humanos , Radioterapia de Intensidad Modulada , Tolerancia Inmunológica , Carcinoma Nasofaríngeo , Curva ROC , Neoplasias Nasofaríngeas/radioterapia
2.
Zhongguo Yi Liao Qi Xie Za Zhi ; (6): 417-420, 2018.
Artículo en Chino | WPRIM | ID: wpr-775541

RESUMEN

Telemedicine technology is a means of deploying medical resources with low cost and high efficiency. A set of remote radiotherapy system based on Citrix was designed in this paper, so that the senior radiation therapists from the developed areas can provide medical services effectively for the patients in the rural areas. This paper focused on the design ideas and the detail of the technical implementation of how to design a remote radiotherapy system based on the existing equipment in the primary hospital. And the technical reliability and security of the remote radiotherapy system were verified by the scientific test method with pairwise comparison. The early practical experience shows that through the remote radiotherapy system the primary radiotherapy personnel and the radiotherapy experts from thirdgrade class-A hospital can form effective alliance in radiotherapy techniques to allow patients in rural areas to receive more professional radiation therapy.


Asunto(s)
Humanos , Sistemas de Información , Radioterapia , Reproducibilidad de los Resultados , Telemedicina
3.
Zhongguo Yi Liao Qi Xie Za Zhi ; (6): 225-227, 2015.
Artículo en Chino | WPRIM | ID: wpr-265657

RESUMEN

<p><b>OBJECTIVE</b>The automatic generation of planning targets and auxiliary contours have achieved in Eclipse TPS 11.0.</p><p><b>METHODS</b>The scripting language autohotkey was used to develop a software for automatically generated contours in Eclipse TPS. This software is named Contour Auto Margin (CAM), which is composed of operational functions of contours, script generated visualization and script file operations. RESULTS Ten cases in different cancers have separately selected, in Eclipse TPS 11.0 scripts generated by the software could not only automatically generate contours but also do contour post-processing. For different cancers, there was no difference between automatically generated contours and manually created contours.</p><p><b>CONCLUSION</b>The CAM is a user-friendly and powerful software, and can automatically generated contours fast in Eclipse TPS 11.0. With the help of CAM, it greatly save plan preparation time and improve working efficiency of radiation therapy physicists.</p>


Asunto(s)
Humanos , Planificación de la Radioterapia Asistida por Computador , Programas Informáticos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA